Chapter 5 — FLOORS

Section R503

California Residential Code (Title 24, Part 2.5) · 2022 edition · updated 2026-09-12 · California

Italicized text is a California amendment to the model code, as printed in the official publication.

R503.1 Lumber sheathing.

Maximum allowable spans for lumber used as floor sheathing shall conform to Tables R503.1, R503.2.1.1(1) and R503.2.1.1(2).

TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING

5-12 2022 CALIFORNIA RESIDENTIAL CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND

SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT a, b, c

SPAN
RATING
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
ALLOWABLE LIVE LOAD
(psf)h, I
MAXIMUM SPAN
(inches)
LOAD
(pounds per square foot, at maximum span)
MAXIMUM SPAN
(inches)
SPAN
RATING
MINIMUM
NOMINAL
PANEL
THICKNESS
(inch)
SPAN
@ 16″ o.c.
SPAN
@ 24″ o.c.
With edge
supportd
Without edge
support
Total load Live load Live load
Sheathinge Sheathinge Rooff Rooff Rooff Rooff Subfloorj
16/0 3/8 30 16 16 40 30 0
20/0 3/8 50 20 20 40 30 0
24/0 3/8 100 30 24 20g 40 30 0
24/16 7/16 100 40 24 24 50 40 16
32/16 15/32, 1/2 180 70 32 28 40 30 16h
40/20 19/32, 5/8 305 130 40 32 40 30 20h, i
48/24 23/32, 3/4 175 48 36 45 35 24
60/32 7/8 305 60 48 45 35 32
Underlayment,
C-C plugged, single floore
Underlayment,
C-C plugged, single floore
Rooff Rooff Rooff Rooff Combination
subfloor
underlaymentk
16 o.c. 19/32, 5/8 100 40 24 24 50 40 16i
20 o.c. 19/32, 5/8 150 60 32 32 40 30 20i, j
24 o.c. 23/32, 3/4 240 100 48 36 35 25 24
32 o.c. 7/8 185 48 40 50 40 32
48 o.c. 13/32, 11/8 290 60 48 50 40 48

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa. a. The allowable total loads were determined using a dead load of 10 psf. If the dead load exceeds 10 psf, then the live load shall be reduced accordingly. b. Panels continuous over two or more spans with long dimension (strength axis) perpendicular to supports. Spans shall be limited to values shown because of

possible effect of concentrated loads. c. Applies to panels 24 inches or wider. d. Lumber blocking, panel edge clips (one midway between each support, except two equally spaced between supports where span is 48 inches), tongue-and groove panel edges, or other approved type of edge support. e. Includes Structural I panels in these grades. f. Uniform load deflection limitation: 1 /180 of span under live load plus dead load, 1 /240 of span under live load only. g. Maximum span 24 inches for 15 /32- and 1 /2-inch panels. h. Maximum span 24 inches where 3 /4-inch wood finish flooring is installed at right angles to joists. i. Maximum span 24 inches where 1.5 inches of lightweight concrete or approved cellular concrete is placed over the subfloor. j. Unsupported edges shall have tongue-and-groove joints or shall be supported with blocking unless minimum nominal 1 /4-inch-thick wood panel-type

underlayment, fiber-cement underlayment with end and edge joints offset not less than 2 inches or 1 1 /2 inches of lightweight concrete or approved cellular concrete is placed over the subfloor, or 3 /4-inch wood finish flooring is installed at right angles to the supports. Fiber-cement underlayment shall comply with ASTM C1288 or ISO 8336 Category C. Allowable uniform live load at maximum span, based on deflection of 1 /360 of span, is 100 psf. k. Unsupported edges shall have tongue-and-groove joints or shall be supported by blocking unless nominal 1 /4-inch-thick wood panel-type underlayment, fiber cement underlayment with end and edge joints offset not less than 2 inches or 3 /4-inch wood finish flooring is installed at right angles to the supports. Fibercement underlayment shall comply with ASTM C1288 or ISO 8336 Category C. Allowable uniform live load at maximum span, based on deflection of 1 /360 of span, is 100 psf, except panels with a span rating of 48 on center are limited to 65 psf total uniform load at maximum span. l. Allowable live load values at spans of 16 inches on center and 24 inches on center taken from referenced standard APA E30, APA Engineered Wood

Construction Guide . Refer to referenced standard for allowable spans not listed in the table.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENT a

IDENTIFICATION SPACING OF JOISTS (inches)
IDENTIFICATION 16 20 24
Species groupb
1 1/2 5/8 3/4
2, 3 5/8 3/4 7/8
4 3/4 7/8 1

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa. a. Plywood continuous over two or more spans and face grain perpendicular

to supports. Unsupported edges shall be tongue-and-groove or blocked except where nominal 1 /4-inch-thick wood panel-type underlayment, fibercement underlayment or 3 /4-inch wood finish floor is used. Fiber-cement underlayment shall comply with ASTM C1288 or ISO 8336 Category C. Allowable uniform live load at maximum span based on deflection of 1 /360 of span is 100 psf. b. Applicable to all grades of sanded exterior-type plywood.

R503.2.2 Allowable spans. The maximum allowable span for wood structural panels used as subfloor or combination subfloor underlayment shall be as set forth in Table R503.2.1.1(1), or APA E30. The maximum span for sanded plywood combination subfloor underlayment shall be as set forth in Table R503.2.1.1(2).

R503.2.3 Installation. Wood structural panels used as subfloor or combination subfloor underlayment shall be attached to wood framing in accordance with Table R602.3(1) and shall be attached to cold-formed steel framing in accordance with Table R505.3.1(2).

R503.3 Particleboard.

R503.3.1 Identification and grade. Particleboard shall conform to ANSI A208.1 and shall be so identified by a grade mark or certificate of inspection issued by an approved agency.

R503.3.2 Floor underlayment. Particleboard floor underlayment shall conform to Type PBU and shall be not less than 1 /4 inch (6.4 mm) in thickness.

R503.3.3 Installation. Particleboard underlayment shall be installed in accordance with the recommendations of the manufacturer and attached to framing in accordance with Table R602.3(1).