R502.1 General.

Wood and wood-based products used for load-supporting purposes shall conform to the applicable provisions of this section.

R502.1.1 Sawn lumber. Sawn lumber shall be identified by a grade mark of an accredited lumber grading or inspection agency and have design values certified by an accreditation body that complies with DOC PS 20. In lieu of a grade mark, a certificate of inspection issued by a lumber grading or inspection agency meeting the requirements of this section shall be accepted.

Note: See Section R301.1.1.1 for limited-density owner- built rural dwellings. R502.1.1.1 Preservative-treated lumber. Preservative treated dimension lumber shall be identified as required by Section R317.2. R502.1.1.2 End-jointed lumber. Approved end-jointed lumber identified by a grade mark conforming to Section R502.1.1 shall be permitted to be used interchangeably with solid-sawn members of the same species and grade. End-jointed lumber used in an assembly required elsewhere in this code to have a fire-resistance rating shall have the designation “Heat-Resistant Adhesive” or “HRA” included in its grade mark. R502.1.2 Prefabricated wood I-joists. Structural capacities and design provisions for prefabricated wood I-joists shall be established and monitored in accordance with ASTM D5055. R502.1.3 Structural glued laminated timbers. Glued laminated timbers shall be manufactured and identified as required in ANSI A190.1, ANSI 117 and ASTM D3737.

R502.1.4 Structural log members. Structural log members shall comply with the provisions of ICC 400.

R502.1.5 Structural composite lumber. Structural capacities for structural composite lumber shall be established and monitored in accordance with ASTM D5456.

R502.1.6 Cross-laminated timber. Cross-laminated timber shall be manufactured and identified as required by ANSI/APA PRG 320.

R502.1.7 Engineered wood rim board. Engineered wood rim boards shall conform to ANSI/APA PRR 410 or shall be evaluated in accordance with ASTM D7672. Structural capacities shall be in accordance with ANSI/APA PRR 410 or established in accordance with ASTM D7672. Rim boards conforming to ANSI/APA PRR 410 shall be marked in accordance with that standard.

R502.2 Design and construction.

Floors shall be designed and constructed in accordance with the provisions of this chapter, Figure R502.2 and Sections R317 and R318 or in accordance with ANSI AWC NDS.

R502.2.1 Framing at braced wall lines. A load path for lateral forces shall be provided between floor framing and braced wall panels located above or below a floor, as specified in Section R602.10.8.

R502.2.2 Blocking and subflooring. Blocking for fastening panel edges or fixtures shall be not less than utility grade lumber. Subflooring shall be not less than utility grade lumber, No. 4 common grade boards or wood structural panels as specified in Section R503.2. Fireblocking shall be of any grade lumber.

R502.3 Allowable joist spans.

Spans for floor joists shall be in accordance with Tables R502.3.1(1) and R502.3.1(2). For other grades and species and for other loading conditions, refer to the AWC STJR.

R502.3.1 Sleeping areas and attic joists. Table R502.3.1(1) shall be used to determine the maximum allowable span of floor joists that support sleeping areas and attics that are accessed by means of a fixed stairway in accordance with Section R311.7 provided that the design live load does not exceed 30 pounds per square foot (1.44 kPa) and the design dead load does not exceed 20 pounds per square foot (0.96 kPa). The allowable span of ceiling joists that support attics used for limited storage or no storage shall be determined in accordance with Section R802.5.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

PLATE

FLOOR

R1001.11

FIREPLACE

SOLID

SUBFLOOR OR

SILL PLATE

BAND, RIM OR HEADER JOIST

PARTITIONS. IF JOISTS ARE SEPARATED FOR PIPES, BLOCK

4 FT. ON-CENTER MAXIMUM

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.

FIGURE R502.2 FLOOR CONSTRUCTION

5-4 2022 CALIFORNIA RESIDENTIAL CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) a

JOIST
SPACING
(inches)
SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 20 psf
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in)
12 Douglas fir-larch SS 12-6 16-6 21-0 25-7 12-6 16-6 21-0 25-7
12 Douglas fir-larch #1 12-0 15-10 20-3 24-8 12-0 15-7 19-0 22-0
12 Douglas fir-larch #2 11-10 15-7 19-10 23-4 11-8 14-9 18-0 20-11
12 Douglas fir-larch #3 9-11 12-7 15-5 17-10 8-11 11-3 13-9 16-0
12 Hem-fir SS 11-10 15-7 19-10 24-2 11-10 15-7 19-10 24-2
12 Hem-fir #1 11-7 15-3 19-5 23-7 11-7 15-3 18-9 21-9
12 Hem-fir #2 11-0 14-6 18-6 22-6 11-0 14-4 17-6 20-4
12 Hem-fir #3 9-8 12-4 15-0 17-5 8-8 11-0 13-5 15-7
12 Southern pine SS 12-3 16-2 20-8 25-1 12-3 16-2 20-8 25-1
12 Southern pine #1 11-10 15-7 19-10 24-2 11-10 15-7 18-7 22-0
12 Southern pine #2 11-3 14-11 18-1 21-4 10-9 13-8 16-2 19-1
12 Southern pine #3 9-2 11-6 14-0 16-6 8-2 10-3 12-6 14-9
12 Spruce-pine-fir SS 11-7 15-3 19-5 23-7 11-7 15-3 19-5 23-7
12 Spruce-pine-fir #1 11-3 14-11 19-0 23-0 11-3 14-7 17-9 20-7
12 Spruce-pine-fir #2 11-3 14-11 19-0 23-0 11-3 14-7 17-9 20-7
12 Spruce-pine-fir #3 9-8 12-4 15-0 17-5 8-8 11-0 13-5 15-7
16 Douglas fir-larch SS 11-4 15-0 19-1 23-3 11-4 15-0 19-1 23-3
16 Douglas fir-larch #1 10-11 14-5 18-5 21-4 10-8 13-6 16-5 19-1
16 Douglas fir-larch #2 10-9 14-2 17-5 20-3 10-1 12-9 15-7 18-1
16 Douglas fir-larch #3 8-7 10-11 13-4 15-5 7-8 9-9 11-11 13-10
16 Hem-fir SS 10-9 14-2 18-0 21-11 10-9 14-2 18-0 21-11
16 Hem-fir #1 10-6 13-10 17-8 21-1 10-6 13-4 16-3 18-10
16 Hem-fir #2 10-0 13-2 16-10 19-8 9-10 12-5 15-2 17-7
16 Hem-fir #3 8-5 10-8 13-0 15-1 7-6 9-6 11-8 13-6
16 Southern pine SS 11-2 14-8 18-9 22-10 11-2 14-8 18-9 22-10
16 Southern pine #1 10-9 14-2 18-0 21-4 10-9 13-9 16-1 19-1
16 Southern pine #2 10-3 13-3 15-8 18-6 9-4 11-10 14-0 16-6
16 Southern pine #3 7-11 10-0 11-1 14-4 7-1 8-11 10-10 12-10
16 Spruce-pine-fir SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-4
16 Spruce-pine-fir #1 10-3 13-6 17-2 19-11 9-11 12-7 15-5 17-10
16 Spruce-pine-fir #2 10-3 13-6 17-2 19-11 9-11 12-7 15-5 17-10
16 Spruce-pine-fir #3 8-5 10-8 13-0 15-1 7-6 9-6 11-8 13-6

(continued)

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360) a

JOIST
SPACING
(inches)
SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 20 psf
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in)
19.2 Douglas fir-larch SS 10-8 14-1 18-0 21-10 10-8 14-1 18-0 21-4
19.2 Douglas fir-larch #1 10-4 13-7 16-9 19-6 9-8 12-4 15-0 17-5
19.2 Douglas fir-larch #2 10-1 13-0 15-11 18-6 9-3 11-8 14-3 16-6
19.2 Douglas fir-larch #3 7-10 10-0 12-2 14-1 7-0 8-11 10-11 12-7
19.2 Hem-fir SS 10-1 13-4 17-0 20-8 10-1 13-4 17-0 20-7
19.2 Hem-fir #1 9-10 13-0 16-7 19-3 9-7 12-2 14-10 17-2
19.2 Hem-fir #2 9-5 12-5 15-6 17-1 8-11 11-4 13-10 16-1
19.2 Hem-fir #3 7-8 9-9 11-10 13-9 6-10 8-8 10-7 12-4
19.2 Southern pine SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-6
19.2 Southern pine #1 10-1 13-4 16-5 19-6 9-11 12-7 14-8 17-5
19.2 Southern pine #2 9-6 12-1 14-4 16-10 8-6 10-10 12-10 15-1
19.2 Southern pine #3 7-3 9-1 11-0 13-1 6-5 8-2 9-10 11-8
19.2 Spruce-pine-fir SS 9-10 13-0 16-7 20-2 9-10 13-0 16-7 19-6
19.2 Spruce-pine-fir #1 9-8 12-9 15-8 18-3 9-1 11-6 14-1 16-3
19.2 Spruce-pine-fir #2 9-8 12-9 15-8 18-3 9-1 11-6 14-1 16-3
19.2 Spruce-pine-fir #3 7-8 9-9 11-10 13-9 6-10 8-8 10-7 12-4
24 Douglas fir-larch SS 9-11 13-1 16-8 20-3 9-11 13-1 16-5 19-1
24 Douglas fir-larch #1 9-7 12-4 15-0 17-5 8-8 11-0 13-5 15-7
24 Douglas fir-larch #2 9-3 11-8 14-3 16-6 8-3 10-5 12-9 14-9
24 Douglas fir-larch #3 7-0 8-11 10-11 12-7 6-3 8-0 9-9 11-3
24 Hem-fir SS 9-4 12-4 15-9 19-2 9-4 12-4 15-9 18-5
24 Hem-fir #1 9-2 12-1 14-10 17-2 8-7 10-10 13-3 15-5
24 Hem-fir #2 8-9 11-4 13-10 16-1 8-0 10-2 12-5 14-4
24 Hem-fir #3 6-10 8-8 10-7 12-4 6-2 7-9 9-6 11-0
24 Southern pine SS 9-9 12-10 16-5 19-11 9-9 12-10 16-5 19-8
24 Southern pine #1 9-4 12-4 14-8 17-5 8-10 11-3 13-1 15-7
24 Southern pine #2 8-6 10-10 12-10 15-1 7-7 9-8 11-5 13-6
24 Southern pine #3 6-5 8-2 9-10 11-8 5-9 7-3 8-10 10-5
24 Spruce-pine-fir SS 9-2 12-1 15-5 18-9 9-2 12-1 15-0 17-5
24 Spruce-pine-fir #1 8-11 11-6 14-1 16-3 8-1 10-3 12-7 14-7
24 Spruce-pine-fir #2 8-11 11-6 14-1 16-3 8-1 10-3 12-7 14-7
24 Spruce-pine-fir #3 6-10 8-8 10-7 12-4 6-2 7-9 9-6 11-0

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. Note: Check sources for availability of lumber in lengths greater than 20 feet. a. Dead load limits for townhouses in Seismic Design Category C and all structures in Seismic Design Categories D0, D1 and D2 shall be determined in

accordance with Section R301.2.2.2.

5-6 2022 CALIFORNIA RESIDENTIAL CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) b

JOIST
SPACING
(inches)
SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 20 psf
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in)
12 Douglas fir-larch SS 11-4 15-0 19-1 23-3 11-4 15-0 19-1 23-3
12 Douglas fir-larch #1 10-11 14-5 18-5 22-0 10-11 14-2 17-4 20-1
12 Douglas fir-larch #2 10-9 14-2 18-0 20-11 10-8 13-6 16-5 19-1
12 Douglas fir-larch #3 8-11 11-3 13-9 16-0 8-1 10-3 12-7 14-7
12 Hem-fir SS 10-9 14-2 18-0 21-11 10-9 14-2 18-0 21-11
12 Hem-fir #1 10-6 13-10 17-8 21-6 10-6 13-10 17-1 19-10
12 Hem-fir #2 10-0 13-2 16-10 20-4 10-0 13-1 16-0 18-6
12 Hem-fir #3 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
12 Southern pine SS 11-2 14-8 18-9 22-10 11-2 14-8 18-9 22-10
12 Southern pine #1 10-9 14-2 18-0 21-11 10-9 14-2 16-11 20-1
12 Southern pine #2 10-3 13-6 16-2 19-1 9-10 12-6 14-9 17-5
12 Southern pine #3 8-2 10-3 12-6 14-9 7-5 9-5 11-5 13-6
12 Spruce-pine-fir SS 10-6 13-10 17-8 21-6 10-6 13-10 17-8 21-6
12 Spruce-pine-fir #1 10-3 13-6 17-3 20-7 10-3 13-3 16-3 18-10
12 Spruce-pine-fir #2 10-3 13-6 17-3 20-7 10-3 13-3 16-3 18-10
12 Spruce-pine-fir #3 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
16 Douglas fir-larch SS 10-4 13-7 17-4 21-1 10-4 13-7 17-4 21-1
16 Douglas fir-larch #1 9-11 13-1 16-5 19-1 9-8 12-4 15-0 17-5
16 Douglas fir-larch #2 9-9 12-9 15-7 18-1 9-3 11-8 14-3 16-6
16 Douglas fir-larch #3 7-8 9-9 11-11 13-10 7-0 8-11 10-11 12-7
16 Hem-fir SS 9-9 12-10 16-5 19-11 9-9 12-10 16-5 19-11
16 Hem-fir #1 9-6 12-7 16-0 18-10 9-6 12-2 14-10 17-2
16 Hem-fir #2 9-1 12-0 15-2 17-7 8-11 11-4 13-10 16-1
16 Hem-fir #3 7-6 9-6 11-8 13-6 6-10 8-8 10-7 12-4
16 Southern pine SS 10-2 13-4 17-0 20-9 10-2 13-4 17-0 20-9
16 Southern pine #1 9-9 12-10 16-1 19-1 9-9 12-7 14-8 17-5
16 Southern pine #2 9-4 11-10 14-0 16-6 8-6 10-10 12-10 15-1
16 Southern pine #3 7-1 8-11 10-10 12-10 6-5 8-2 9-10 11-8
16 Spruce-pine-fir SS 9-6 12-7 16-0 19-6 9-6 12-7 16-0 19-6
16 Spruce-pine-fir #1 9-4 12-3 15-5 17-10 9-1 11-6 14-1 16-3
16 Spruce-pine-fir #2 9-4 12-3 15-5 17-10 9-1 11-6 14-1 16-3
16 Spruce-pine-fir #3 7-6 9-6 11-8 13-6 6-10 8-8 10-7 12-4

(continued)

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360) b

JOIST
SPACING
(inches)
SPECIES AND GRADE DEAD LOAD = 10 psf DEAD LOAD = 20 psf
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE 2 × 6 2 × 8 2 × 10 2 × 12 2 × 6 2 × 8 2 × 10 2 × 12
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans Maximum floor joist spans
JOIST
SPACING
(inches)
SPECIES AND GRADE SPECIES AND GRADE (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in) (ft-in)
19.2 Douglas fir-larch SS 9-8 12-10 16-4 19-10 9-8 12-10 16-4 19-6
19.2 Douglas fir-larch #1 9-4 12-4 15-0 17-5 8-10 11-3 13-8 15-11
19.2 Douglas fir-larch #2 9-2 11-8 14-3 16-6 8-5 10-8 13-0 15-1
19.2 Douglas fir-larch #3 7-0 8-11 10-11 12-7 6-5 8-2 9-11 11-6
19.2 Hem-fir SS 9-2 12-1 15-5 18-9 9-2 12-1 15-5 18-9
19.2 Hem-fir #1 9-0 11-10 14-10 17-2 8-9 11-1 13-6 15-8
19.2 Hem-fir #2 8-7 11-3 13-10 16-1 8-2 10-4 12-8 14-8
19.2 Hem-fir #3 6-10 8-8 10-7 12-4 6-3 7-11 9-8 11-3
19.2 Southern pine SS 9-6 12-7 16-0 19-6 9-6 12-7 16-0 19-6
19.2 Southern pine #1 9-2 12-1 14-8 17-5 9-0 11-5 13-5 15-11
19.2 Southern pine #2 8-6 10-10 12-10 15-1 7-9 9-10 11-8 13-9
19.2 Southern pine #3 6-5 8-2 9-10 11-8 5-11 7-5 9-0 10-8
19.2 Spruce-pine-fir SS 9-0 11-10 15-1 18-4 9-0 11-10 15-1 17-9
19.2 Spruce-pine-fir #1 8-9 11-6 14-1 16-3 8-3 10-6 12-10 14-10
19.2 Spruce-pine-fir #2 8-9 11-6 14-1 16-3 8-3 10-6 12-10 14-10
19.2 Spruce-pine-fir #3 6-10 8-8 10-7 12-4 6-3 7-11 9-8 11-3
24 Douglas fir-larch SS 9-0 11-11 15-2 18-5 9-0 11-11 15-0 17-5
24 Douglas fir-larch #1 8-8 11-0 13-5 15-7 7-11 10-0 12-3 14-3
24 Douglas fir-larch #2 8-3 10-5 12-9 14-9 7-6 9-6 11-8 13-6
24 Douglas fir-larch #3 6-3 8-0 9-9 11-3 5-9 7-3 8-11 10-4
24 Hem-fir SS 8-6 11-3 14-4 17-5 8-6 11-3 14-4 16-10a
24 Hem-fir #1 8-4 10-10 13-3 15-5 7-10 9-11 12-1 14-0
24 Hem-fir #2 7-11 10-2 12-5 14-4 7-4 9-3 11-4 13-1
24 Hem-fir #3 6-2 7-9 9-6 11-0 5-7 7-1 8-8 10-1
24 Southern pine SS 8-10 11-8 14-11 18-1 8-10 11-8 14-11 18-0
24 Southern pine #1 8-6 11-3 13-1 15-7 8-1 10-3 12-0 14-3
24 Southern pine #2 7-7 9-8 11-5 13-6 7-0 8-10 10-5 12-4
24 Southern pine #3 5-9 7-3 8-10 10-5 5-3 6-8 8-1 9-6
24 Spruce-pine-fir SS 8-4 11-0 14-0 17-0 8-4 11-0 13-8 15-11
24 Spruce-pine-fir #1 8-1 10-3 12-7 14-7 7-5 9-5 11-6 13-4
24 Spruce-pine-fir #2 8-1 10-3 12-7 14-7 7-5 9-5 11-6 13-4
24 Spruce-pine-fir #3 6-2 7-9 9-6 11-0 5-7 7-1 8-8 10-1

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. Note: Check sources for availability of lumber in lengths greater than 20 feet. a. End bearing length shall be increased to 2 inches. b. Dead load limits for townhouses in Seismic Design Category C and all structures in Seismic Design Categories D0, D1, and D2 shall be determined in

accordance with Section R301.2.2.2.

5-8 2022 CALIFORNIA RESIDENTIAL CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

R502.3.2 Other floor joists. Table R502.3.1(2) shall be used to determine the maximum allowable span of floor joists that support other areas of the building, other than sleeping areas and attics, provided that the design live load does not exceed 40 pounds per square foot (1.92 kPa) and the design dead load does not exceed 20 pounds per square foot (0.96 kPa).

R502.3.3 Floor cantilevers. Floor cantilever spans shall not exceed the nominal depth of the wood floor joist. Floor cantilevers constructed in accordance with Table R502.3.3(1) shall be permitted where supporting a lightframe bearing wall and roof only. Floor cantilevers supporting an exterior balcony are permitted to be constructed in accordance with Table R502.3.3(2).

R502.4 Joists under bearing partitions.

Joists under parallel bearing partitions shall be of adequate size to support the load. Double joists, sized to adequately support the load, that are separated to permit the installation of piping or vents shall be full-depth solid blocked with lumber not less than 2 inches (51 mm) in nominal thickness spaced not more than 4 feet (1219 mm) on center. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth unless such joists are of sufficient size to carry the additional load.

FLOORS

R502.5 Allowable girder and header spans.

The allowable spans of girders and headers fabricated of dimension lumber shall not exceed the values set forth in Tables R602.7(1), R602.7(2) and R602.7(3).

R502.6 Bearing.

The ends of each joist, beam or girder shall have not less than 1 1 /2 inches (38 mm) of bearing on wood or metal, have not less than 3 inches of bearing (76 mm) on masonry or concrete or be supported by approved joist hangers. Alternatively, the ends of joists shall be supported on a 1inch by 4-inch (25 mm by 102 mm) ribbon strip and shall be nailed to the adjacent stud. The bearing on masonry or concrete shall be direct, or a sill plate of 2-inch-minimum (51 mm) nominal thickness shall be provided under the joist, beam or girder. The sill plate shall provide a minimum nominal bearing area of 48 square inches (30 865 mm 2 ).

R502.6.1 Floor systems. Joists framing from opposite sides over a bearing support shall lap not less than 3 inches (76 mm) and shall be nailed together with a minimum three 10d face nails. A wood or metal splice with strength equal to or greater than that provided by the nailed lap is permitted.

R502.6.2 Joist framing. Joists framing into the side of a wood girder shall be supported by approved framing anchors or on ledger strips not less than nominal 2 inches by 2 inches (51 mm by 51 mm).

TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY a, b, c, f, g, h

(Floor live load ≤ 40 psf, roof live load ≤ 20 psf)
MEMBER & SPACING MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)d, e
MEMBER & SPACING Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load Ground Snow Load
MEMBER & SPACING ≤ 20 psf ≤ 20 psf ≤ 20 psf 30 psf 30 psf 30 psf 50 psf 50 psf 50 psf 70 psf 70 psf 70 psf
MEMBER & SPACING Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width Roof Width
MEMBER & SPACING 24 ft 32 ft 40 ft 24 ft 32 ft 40 ft 24 ft 32 ft 40 ft 24 ft 32 ft 40 ft
2 × 8 @ 12″ 20″
(177)
15″
(227)
18″
(209)
2 × 10 @ 16″ 29″
(228)
21″
(297)
16″
(364)
26″
(271)
18″
(354)
20″
(375)
2 × 10 @ 12″ 36″
(166)
26″
(219)
20″
(270)
34″
(198)
22″
(263)
16″
(324)
26″
(277)
19″
(356)
2 × 12 @ 16″ 32″
(287)
25″
(356)
36″
(263)
29″
(345)
21″
(428)
29″
(367)
20″
(484)
23″
(471)
2 × 12 @ 12″ 42″
(209)
31″
(263)
37″
(253)
27″
(317)
36″
(271)
27″
(358)
17″
(447)
31″
(348)
19″
(462)
2 × 12 @ 8″ 48″
(136)
45″
(169)
48″
(164)
38″
(206)
40″
(233)
26″
(294)
36″
(230)
29″
(304)
18″
(379)

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Tabulated values are for clear-span roof supported solely by exterior bearing walls. b. Spans are based on No. 2 Grade lumber of Douglas fir-larch, Southern pine, hem-fir and spruce-pine-fir for repetitive (three or more) members. c. Ratio of backspan to cantilever span shall be not less than 3:1. d. Connections capable of resisting the indicated uplift force shall be provided at the backspan support. e. Uplift force is for a backspan to cantilever span ratio of 3:1. Tabulated uplift values are permitted to be reduced by multiplying by a factor equal to 3 divided

by the actual backspan ratio provided (3/backspan ratio). f. See Section R301.2.2.6, Item 1, for additional limitations on cantilevered floor joists for detached one- and two-family dwellings in Seismic Design Category

D0, D1 or D2 and townhouses in Seismic Design Category C, D0, D1 or D2. g. A full-depth rim joist shall be provided at the unsupported end of the cantilever joists. Solid blocking shall be provided at the supported end. Where the

cantilever length is 24 inches or less and the building is assigned to Seismic Design Category A, B or C, solid blocking at the support for the cantilever shall not be required. h. Linear interpolation shall be permitted for building widths and ground snow loads other than shown.

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY a, b, e, f

MEMBER SIZE SPACING MAXIMUM CANTILEVER SPAN (uplift force at backspan support in lb)c, d
MEMBER SIZE SPACING Ground Snow Load Ground Snow Load Ground Snow Load
MEMBER SIZE SPACING ≤ 30 psf 50 psf 70 psf
2 × 8 12″ 42″ (139) 39″ (156) 34″ (165)
2 × 8 16″ 36″ (151) 34″ (171) 29″ (180)
2 × 10 12″ 61″ (164) 57″ (189) 49″ (201)
2 × 10 16″ 53″ (180) 49″ (208) 42″ (220)
2 × 10 24″ 43″ (212) 40″ (241) 34″ (255)
2 × 12 16″ 72″ (228) 67″ (260) 57″ (268)
2 × 12 24″ 58″ (279) 54″ (319) 47″ (330)

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa. a. Spans are based on No. 2 Grade lumber of Douglas fir-larch, Southern pine, hem-fir, and spruce-pine-fir for repetitive (three or more) members. b. Ratio of backspan to cantilever span shall be not less than 2:1. c. Connections capable of resisting the indicated uplift force shall be provided at the backspan support. d. Uplift force is for a backspan to cantilever span ratio of 2:1. Tabulated uplift values are permitted to be reduced by multiplying by a factor equal to 2 divided

, and spruce-pine-fir for repetitive (three or more) members. b. Ratio of backspan to cantilever span shall be not less than 2:1. c. Connections capable of resisting the indicated uplift force shall be provided at the backspan support. d. Uplift force is for a backspan to cantilever span ratio of 2:1. Tabulated uplift values are permitted to be reduced by multiplying by a factor equal to 2 divided

by the actual backspan ratio provided (2/backspan ratio). e. A full-depth rim joist shall be provided at the unsupported end of the cantilever joists. Solid blocking shall be provided at the supported end. Where the

cantilever length is 24 inches or less and the building is assigned to Seismic Design Category A, B or C, solid blocking at the support for the cantilever shall not be required. f. Linear interpolation shall be permitted for ground snow loads other than shown.

R502.7 Lateral restraint at supports.

Joists shall be supported laterally at the ends by full-depth solid blocking not less than 2 inches (51 mm) nominal in thickness; or by attachment to a full-depth header, band or rim joist, or to an adjoining stud or shall be otherwise provided with lateral support to prevent rotation.

Exceptions:

  1. Trusses, structural composite lumber, structural glued-laminated members and I-joists shall be supported laterally as required by the manufacturer’s recommendations.

  2. In Seismic Design Categories D0, D1 and D2, lateral restraint shall be provided at each intermediate support.

R502.7.1 Bridging. Joists exceeding a nominal 2 inches by 12 inches (51 mm by 305 mm) shall be supported laterally by solid blocking, diagonal bridging (wood or metal), or a continuous 1-inch by 3-inch (25 mm by 76 mm) strip nailed across the bottom of joists perpendicular to joists at intervals not exceeding 8 feet (2438 mm).

Exception: Trusses, structural composite lumber, structural glued-laminated members and I-joists shall be supported laterally as required by the manufacturer’s recommendations.

R502.8 Cutting, drilling and notching.

Structural floor members shall not be cut, bored or notched in excess of the limitations specified in this section. See Figure R502.8.

R502.8.1 Sawn lumber. Notches in solid lumber joists, rafters and beams shall not exceed one-sixth of the depth of the member, shall not be longer than one-third of the depth of the member and shall not be located in the middle one-third of the span. Notches at the ends of the

member shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or greater in nominal thickness shall not be notched except at the ends of the members. The diameter of holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is notched, the hole shall not be closer than 2 inches (51 mm) to the notch.

R502.8.2 Engineered wood products. Cuts, notches and holes bored in trusses, structural composite lumber, structural glue-laminated members, cross-laminated timber members or I-joists are prohibited except where permitted by the manufacturer’s recommendations or where the effects of such alterations are specifically considered in the design of the member by a registered design professional.

R502.9 Fastening.

Floor framing shall be nailed in accordance with Table R602.3(1). Where posts and beam or girder construction is used to support floor framing, positive connections shall be provided to ensure against uplift and lateral displacement.

R502.10 Framing of openings.

Openings in floor framing shall be framed with header and trimmer joists. Where the header joist span does not exceed 4 feet (1219 mm), the header joist shall be a single member the same size as the floor joist. Single trimmer joists shall be used to carry a single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. Where the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be doubled and of sufficient cross section to support the floor joists framing into the header.

5-10 2022 CALIFORNIA RESIDENTIAL CODE

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

For SI: 1 inch = 25.4 mm.

R502.11 Wood trusses.

FIGURE R502.8 CUTTING, NOTCHING AND DRILLING

tices, such as the SBCA Building Component Safety Information (BCSI) Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.

R502.11.3 Alterations to trusses. Truss members and components shall not be cut, notched, spliced or otherwise altered in any way without the approval of a registered design professional. Alterations resulting in the addition of load that exceeds the design load for the truss, shall not be permitted without verification that the truss is capable of supporting the additional loading.

R502.11.4 Truss design drawings. Truss design drawings, prepared in compliance with Section R502.11.1,

R502.11.1 Design. Wood trusses shall be designed in accordance with approved engineering practice. The design and manufacture of metal-plate-connected wood trusses shall comply with ANSI/TPI 1. The truss design drawings shall be prepared by a registered design professional.

R502.11.2 Bracing. Trusses shall be braced to prevent rotation and provide lateral stability in accordance with the requirements specified in the construction documents for the building and on the individual truss design drawings. In the absence of specific bracing requirements, trusses shall be braced in accordance with accepted industry prac

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

FLOORS

shall be submitted to the building official and approved prior to installation. Truss design drawings shall be provided with the shipment of trusses delivered to the job site. Truss design drawings shall include, at a minimum, the information specified as follows:

  1. Slope or depth, span and spacing.

  2. Location of all joints.

  3. Required bearing widths.

  4. Design loads as applicable:

4.1. Top chord live load . 4.2. Top chord dead load. 4.3. Bottom chord live load . 4.4. Bottom chord dead load. 4.5. Concentrated loads and their points of application. 4.6. Controlling wind and earthquake loads.

  1. Adjustments to lumber and joint connector design values for conditions of use.

  2. Each reaction force and direction.

  3. Joint connector type and description, such as size, thickness or gage, and the dimensioned location of each joint connector except where symmetrically located relative to the joint interface.

  4. Lumber size, species and grade for each member.

  5. Connection requirements for:

9.1. Truss-to-girder-truss. 9.2. Truss ply-to-ply. 9.3. Field splices.

  1. Calculated deflection ratio, maximum description for live and total load, or both.

  2. Maximum axial compression forces in the truss members to enable the building designer to design the size, connections and anchorage of the permanent continuous lateral bracing. Forces shall be shown on the truss drawing or on supplemental documents.

  3. Required permanent truss member bracing location.

R502.12 Draftstopping required.

Draftstopping shall be provided in accordance with Section R302.12.

R502.13 Fireblocking required.

Fireblocking shall be provided in accordance with Section R302.11.

JOIST OR BEAM
SPACING (inches)
MINIMUM NET THICKNESS
JOIST OR BEAM
SPACING (inches)
Perpendicular to joist Diagonal to joist
24 11/16 3/4
16 5/8 5/8
48a 11/2 T & G N/A
54b 54b 54b
60c 60c 60c

For SI: 1 inch = 25.4 mm, 1 pound per square inch = 6.895 kPa. N/A = Not Applicable. a. For this support spacing, lumber sheathing shall have a minimum Fb of

675 and minimum E of 1,100,000 (see ANSI AWC NDS). b. For this support spacing, lumber sheathing shall have a minimum Fb of

765 and minimum E of 1,400,000 (see ANSI AWC NDS). c. For this support spacing, lumber sheathing shall have a minimum Fb of

855 and minimum E of 1,700,000 (see ANSI AWC NDS). R503.1.1 End joints. End joints in lumber used as subflooring shall occur over supports unless end-matched lumber is used, in which case each piece shall bear on not less than two joists. Subflooring shall be permitted to be omitted where joist spacing does not exceed 16 inches (406 mm) and a 1-inch (25 mm) nominal tongue-andgroove wood strip flooring is applied perpendicular to the joists.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Residential Code (Title 24, Part 2.5)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.