AU108.1 Fire-resistance rating.¶
Cob walls are not fireresistance rated.
AU108.2 Clearance to fireplaces and chimneys.¶
Cob walls or other cob surfaces shall not require clearance to fireplaces and chimneys, except where clearance to noncombustibles is required by the manufacturer’s instructions.
FIGURE AU106.11.3 CURVED BRACED WALL PANEL
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
APPENDIX AU—COB CONSTRUCTION (MONOLITHIC ADOBE)
TABLE AU106.12 ANCHORAGE OF BOND BEAMS FOR WIND UPLIFT
ANCHORS:
• 5 /8″ ALL THREAD AT 12″ O.C. a, b
• 2″ × 2″ × 1 /4″ WASHERS AND NUT AT END IN COB
• 4″ EMBEDMENT IN CONCRETE BOND BEAMS
| • FULL PENETRATION THROUGH | WOOD BOND BEAMS WITH 2″ × 2″ × 1/ ANCHORAGE DEPTH | /4″ WASHER AND NUT H IN INCHES, PER WALL WIDTH AND W | WIND UPLIFT FORCE |
|---|---|---|---|
| WIND UPLIFT FORCE FROM TABLE R802.11 (PLF) |
ANCHORAGE DEPT ≤ 12″ Wall Widthc |
** IN INCHES, PER WALL WIDTH AND W** ≤ 16″ Wall Widthc |
** IND UPLIFT FORCE** ≤ 24″ wall widthc |
| < 75 | 16 | 12 | 12 |
| < 100 | 24 | 16 | 12 |
| < 150 | 48 o.c. continuous from founda- tion to bond beamd |
24 | 16 |
| < 200 | 48 o.c. continuous from founda- tion to bond beamd |
48 o.c. continuous from founda- tion to bond beamd |
24 |
For SI: 1 inch = 25.4 mm. a. For wood bond beams a maximum of 6 inches from bond beam ends. b. For minimum 6-inch by 8-inch concrete bond beams, at 18″ o.c. for wind uplift forces less than 75 pounds per linear foot, and at 16″ o.c. for wind uplift forces
less than 100 pounds per linear foot. c. Excluding finishes. d. With 7-inch embedment in foundation, 4-inch embedment in concrete bond beam or full penetration through wood bond beam with 2-inch by 2-inch by 1 /4 inch washer and nut.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Residential Code (Title 24, Part 2.5)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix AF — RADON CONTROL
- Appendix AI — PRIVATE SEWAGE
- Appendix AJ — EXISTING
- Appendix AK — SOUND
- Appendix AO — AUTOMATIC
- Appendix AR — LIGHT STRAW-CLAY
- Appendix AS — STRAWBALE
- Appendix AU — COB CONSTRUCTION
- Appendix AV — BOARD
- Appendix AW — 3D-PRINTED BUILDING
- Chapter 1 — SCOPE AND APPLICATION
- Chapter 3 — BUILDING PLANNING
- Chapter 4 — FOUNDATIONS
- Chapter 5 — FLOORS
- Chapter 6 — WALL CONSTRUCTION
- Chapter 7 — WALL COVERING
- Chapter 8 — ROOF-CEILING CONSTRUCTION
- Chapter 9 — ROOF ASSEMBLIES
- Chapter 10 — CHIMNEYS AND FIREPLACES
- Chapter 44 — REFERENCED STANDARDS
- Appendix AH — PATIO COVERS
- Appendix AL — PERMIT FEES
- Appendix AQ — TINY HOUSES
▸Appendix AT — SOLAR-READY PROVISIONS—DETACHED ONE- AND
- Appendix AX — SWIMMING POOL SAFETY ACT
- Appendix AY — AREAS PROTECTED BY THE FACILITIES
- Appendix AZ — EMERGENCY HOUSING