Skip to content

Appendix A4

Section A4.602

California Green Building Standards Code (Title 24, Part 11) · 2022 edition · updated 2026-09-12 · California

RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued

FEATURE OR MEASURE LEVELS
APPLICANT TO SELECT ELECTIVE MEASURES
VERIFICATIONS
ENFORCING AGENCY TO SPECIFY
VERIFICATION METHOD
FEATURE OR MEASURE
Mandatory Prerequisites and electives1 Prerequisites and electives1 Enforcing
Agency

All
Installer or
Designer

All
Third
party

All
FEATURE OR MEASURE
Mandatory Tier 1 Tier 2 Tier 2 Tier 2 Tier 2
WATER EFFICIENCY AND CONSERVATION
Indoor Water Use
4.303.1Plumbing fixtures (water closets and urinals) and fittings
(showerheads, faucets and pre-rinse spray valves) installed in
residential buildings shall comply with the prescriptive requirements
of Sections 4.303.1.1 through 4.303.1.4.5.
4.303.2 Submeters for multifamily building and dwelling units in
mixed-use residential/commercial buildings. Submeters shall be
installed to measure water usage of individual rental dwelling units in
accordance with the_California Plumbing Code._
4.303.3Plumbing fixtures and fittings required in Section 4.303.1
shall be installed in accordance with the_California Plumbing Code,_
and shall meet the applicable referenced standards.
A4.303.1The maximum flow rate of kitchen faucets shall not exceed
1.5 gallons per minute at 60 psi. Kitchen faucets may temporarily
increase the flow above the maximum rate, but not to exceed 2.2
gallons per minute at 60 psi, and must default to a maximum flow
rate of 1.5 gallons per minute at 60 psi.
**Note:**Where complying faucets are unavailable, aerators or other
means may be used to achieve reduction.
4.303.1.4.3 Metering faucets in residential buildings shall not deliver
more than 0.2 gallons per cycle.
A4.303.2Alternate water source for nonpotable applications.
Alternate nonpotable water sources are used for indoor potable water
reduction. Alternate nonpotable water sources shall be installed in
accordance with the_California Plumbing Code._
A4.303.3 Install at least one qualified ENERGY STAR dishwasher
or clothes washer.
A4.303.4Nonwater urinals or waterless toilets are installed.
A4.303.5One- and two-family dwellings shall be equipped with a
demand hot water recirculation system.
Outdoor Water Use
4.304.1 Residential developments shall comply with a local water
efficient landscape ordinance or the current California Department of
Water Resources’ Model Water Efficient Landscape Ordinance
(MWELO), whichever is more stringent.
A4.304.1A rainwater capture, storage and re-use system is designed
and installed.
A4.304.2A landscape design is installed, which does not utilize pota-
ble water.
A4.304.3 For new water service connections, landscaped irrigated
areas less than 5,000 square feet shall be provided with separate
submeters or metering devices for outdoor potable water use.

continued

Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.

APPENDIX A4—RESIDENTIAL VOLUNTARY MEASURES

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Green Building Standards Code (Title 24, Part 11)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.