Chapter 28 — LUMBER YARDS AND AGRO-INDUSTRIAL,
Section 2808
California Fire Code (Title 24, Part 9) · 2022 edition · updated 2026-09-10 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIALS, FINES, COMPOST, SOLID
BIOMASS FEEDSTOCK AND RAW PRODUCT
ASSOCIATED WITH YARD WASTE, AGRO- INDUSTRIAL AND RECYCLING FACILITIES
- The increased pile size shall be based on the capabilities of the installed fire protection systems and features.
- A controlled burn area shall be provided on-site for smoldering or damaged product.
2808.4 Pile separation. Piles or stacked product shall be¶
separated from buildings, property lines and adjacent piles or stacks by a distance of not less than one and one-half times the height of the pile or stack. The distance between rows shall be a minimum of 30 feet (9144 mm). Approved fire apparatus access roads shall be provided within the separation space in accordance with Section 503.
2808.5 Combustible waste. The storage, accumulation and¶
handling of combustible materials and control of vegetation shall comply with Chapter 3.
2808.6 Static pile protection. Static piles shall be monitored¶
by an approved means to measure temperatures within the static piles. Internal pile temperatures shall be monitored and recorded weekly. Such records shall be maintained. An operational plan indicating procedures and schedules for the inspection, monitoring and restricting of excessive internal temperatures in static piles shall be submitted to the fire code official for review and approval.
2808.7 Pile fire protection. Automatic sprinkler protection¶
shall be provided in conveyor tunnels and combustible enclosures that pass under a pile. Combustible conveyor systems and enclosed conveyor systems shall be equipped with an approved automatic sprinkler system.
2808.8 Fire extinguishers. Portable fire extinguishers¶
complying with Section 906 and with a minimum rating of 4A:60-B:C shall be provided on all vehicles and equipment operating on piles and at all processing equipment.
2808.9 Material-handling equipment.¶
Approved materialhandling equipment shall be available for moving wood chips, hogged material, wood fines and raw product during fire-fighting operations.
2808.10 Emergency plan. The owner or operator shall¶
develop a plan for monitoring, controlling and extinguishing spot fires and submit the plan to the fire code official for review and approval.