Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Section 309 — ADDITIONS AND REPLACEMENTS OF EXTERIOR WALL COVERINGS AND EXTERIOR WALL…
2025 California Existing Building Code (Title 24, Part 10) · 2025 edition · updated 2026-07-29 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
309.1 General. ¶
The provisions of Section 309 apply to all alterations, repairs, additions, relocations of structures and changes of occupancy regardless of compliance method.
309.2 Additions and replacements. ¶
Where an exterior wall covering or exterior wall envelope is added or replaced, the materials and methods used shall comply with the requirements for new construction in Chapter 14 and Chapter 26 of the California Building Code if the added or replaced exterior wall covering or exterior wall envelope involves two or more contiguous stories and comprises more than 15 percent of the total wall area on any side of the building.
309.2.1 Automatic sprinkler systems. Combustible exterior wall covering or combustible exterior wall envelopes shall not be added to an existing high-rise building that is not protected throughout with an automatic sprinkler system.
Exceptions:
- Where such material is located on a single story and is less than 15 percent of the wall area on any side of the building.
- Water-resistive barriers installed in accordance with Section 1402.6 of the California Building Code .
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Existing Building Code (Title 24, Part 10)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
-
▸ Chapter 3 — PROVISIONS FOR ALL COMPLIANCE METHODS
Overview- Section 301 — ADMINISTRATION
- Section 302 — GENERAL PROVISIONS
- Section 303 — STORM SHELTERS
- Section 304 — STRUCTURAL DESIGN LOADS AND EVALUATION AND DESIG…
- Section 305 — IN-SITU LOAD TESTS
- Section 306 — ACCESSIBILITY FOR EXISTING BUILDINGS
- Section 307 — SMOKE ALARMS
- Section 308 — CARBON MONOXIDE DETECTION
- Section 309 — ADDITIONS AND REPLACEMENTS OF EXTERIOR WALL COVE…
- Section 310 — [OSHPD 1R, 2 AND 5]—SERVICES/SYSTEMS AND UTILITIES
- Section 311 — [OSHPD 1R, 2 AND 5]—MEANS OF EGRESS
- Section 312 — [OSHPD 1R]—HOSPITAL SPC AND FREESTANDING BUILDIN…
- Section 313 — [SFM]—EXISTING GROUP R-1 AND GROUP R-2 OCCUPANCIES
- Section 314 — [SFM]—EXISTING HIGH-RISE BUILDINGS
- Section 315 — [SFM]—EXISTING GROUP I OCCUPANCIES
- Section 316 — [SFM]—EXISTING GROUP L OCCUPANCIES
- Section 317 — [BSC, DSA-SS & DSA-SS/CC]—EARTHQUAKE EVALUATION …
- Section 318 — [BSC, DSA-SS & DSA-SS/CC]—DEFINITIONS
- Section 319 — [BSC, DSA-SS & DSA-SS/CC]—SEISMIC CRITERIA SELEC…
- Section 320 — [BSC, DSA-SS & DSA-SS/CC]—METHOD A
- Section 321 — [BSC, DSA-SS & DSA-SS/CC]—METHOD B
- Section 322 — [BSC, DSA-SS & DSA-SS/CC]—PEER REVIEW REQUIREMENTS
- Section 323 — [DSA-SS, DSA-SS/CC]—ADDITIONAL REQUIREMENTS FOR …
- Chapter 3A — PROVISIONS FOR ALL COMPLIANCE METHODS
- Chapter 4 — REPAIRS
- Chapter 4A — REPAIRS
- Chapter 5 — PRESCRIPTIVE COMPLIANCE METHOD
- Chapter 5A — PRESCRIPTIVE COMPLIANCE METHOD
- Chapter 6 — CLASSIFICATION OF WORK
- Chapter 7 — ALTERATIONS—LEVEL 1
- Chapter 8 — ALTERATIONS—LEVEL 2
- Chapter 9 — ALTERATIONS—LEVEL 3
- Chapter 10 — CHANGE OF OCCUPANCY
- Chapter 11 — ADDITIONS
- Chapter 12 — HISTORIC BUILDINGS
- Chapter 13 — PERFORMANCE COMPLIANCE METHODS
- Chapter 14 — RELOCATED OR MOVED BUILDINGS
- Chapter 15 — CONSTRUCTION SAFEGUARDS
- Chapter 16 — REFERENCED STANDARDS
- Appendix A — GUIDELINES FOR THE SEISMIC RETROFIT OF EXISTING B…
- Appendix B — SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS FOR EXIS…
- Appendix C — GUIDELINES FOR THE WIND RETROFIT OF EXISTING BUIL…
- Appendix D — BOARD OF APPEALS
- Appendix E — TEMPORARY EMERGENCY USES
- Appendix A — GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS A…