Chapter 11A — HOUSING ACCESSIBILITY
Section 1119A — INTERIOR ACCESSIBLE ROUTES
2025 California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-07-29 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
1119A.1 General. ¶
When a building or portion of a building is required to be accessible or adaptable, an accessible route shall be provided to all portions of the building, accessible building entrances and to covered multifamily dwelling units. The accessible route shall, to the maximum extent feasible, coincide with the route for the general public and other building residents. Accessible routes shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used for similar purposes except within an individual dwell- ing unit.
Interior accessible routes shall be provided as follows:
1. Where more than one route of travel is provided, all routes shall be accessible.
2. At least one accessible route shall connect accessible building or facility entrances with all accessible spaces, elements and covered multifamily dwelling units.
3. An accessible route shall connect at least one accessible primary entrance of each covered multifamily dwelling unit with inte- rior and exterior spaces and facilities that serve the unit.
4. Where elevators are provided for vertical access, all elevators shall be accessible.
11A-14 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
HOUSING ACCESSIBILITY
1119A.2 Floor and ground surfaces. ¶
Floor and ground surfaces shall be stable, firm and slip resistant. If carpet or carpet tile is used in a common use area or public use area on a ground or floor surface, it shall have firm backing or no backing. Carpet or carpet tile shall have a level loop, textured loop, level cut pile or level cut/uncut pile texture. The maximum pile height shall be [1] / 2 inch (12.7 mm). Exposed edges of carpet shall be fastened to floor surfaces and have trim along the entire length of the exposed edge. Carpet edge trim shall comply with Section 1121A requirements for changes in level.
1119A.2.1 Recessed doormats. Recessed doormats shall be adequately anchored to prevent interference with wheelchair traffic.
1119A.3 Widths. ¶
Interior accessible routes serving an occupant load of 10 or more shall not be less than 44 inches (1118 mm) in width. Interior accessible routes serving an occupant load of less than 10 shall not be less than 36 inches (914 mm) in width.
If a person in a wheelchair must make a turn around a corner or an obstruction, the minimum clear width of the accessible route shall be as specified in Section 1138A.1.5.
1119A.4 Interior accessible routes over 200 feet. ¶
Interior accessible routes that exceed 200 feet (60 960 mm) in length shall comply with Section 1138A.1.2. (See Figure 11A-1L.)
1119A.5 Changes in elevation. ¶
Interior accessible routes which have changes in elevation shall be transitioned and comply with Sections 1121A or 1122A.
Exception: Doors and thresholds as provided in Section 1126A.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Building Code (Title 24, Part 2)
- Chapter 1 — ADMINISTRATION
- Chapter 2 — DEFINITIONS
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY A…
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR W…
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11 — RESERVED
-
▸ Chapter 11A — HOUSING ACCESSIBILITY
Overview- Section 1101A — APPLICATION
- Section 1102A — BUILDING ACCESSIBILITY
- Section 1103A — DESIGN AND CONSTRUCTION
- Section 1104A — COVERED MULTIFAMILY DWELLINGS
- Section 1105A — GARAGES, CARPORTS AND PARKING FACILITIES
- Section 1106A — SITE AND BUILDING CHARACTERISTICS
- Section 1107A — DEFINITIONS
- Section 1108A — GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AN…
- Section 1109A — PARKING FACILITIES
- Section 1110A — EXTERIOR ACCESSIBLE ROUTES
- Section 1111A — CHANGES IN LEVEL ON ACCESSIBLE ROUTES
- Section 1112A — CURB RAMPS ON ACCESSIBLE ROUTES
- Section 1113A — WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES
- Section 1114A — EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
- Section 1115A — EXTERIOR STAIRWAYS
- Section 1116A — HAZARDS ON ACCESSIBLE ROUTES
- Section 1117A — GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES,…
- Section 1118A — EGRESS AND AREAS OF REFUGE
- Section 1119A — INTERIOR ACCESSIBLE ROUTES
- Section 1120A — RESERVED
- Section 1121A — CHANGES IN LEVEL ON ACCESSIBLE ROUTES
- Section 1122A — INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
- Section 1123A — INTERIOR STAIRWAYS
- Section 1124A — ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
- Section 1125A — HAZARDS ON ACCESSIBLE ROUTES
- Section 1126A — DOORS, GATES AND WINDOWS
- Section 1127A — COMMON USE FACILITIES
- Section 1128A — COVERED DWELLING UNITS
- Section 1129A — RESERVED
- Section 1130A — ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DW…
- Section 1131A — CHANGES IN LEVEL ON ACCESSIBLE ROUTES
- Section 1132A — DOORS
- Section 1133A — KITCHENS
- Section 1134A — BATHING AND TOILET FACILITIES
- Section 1135A — LAUNDRY ROOMS
- Section 1136A — ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIG…
- Section 1137A — OTHER FEATURES AND FACILITIES
- Section 1138A — SPACE ALLOWANCES AND REACH RANGES
- Section 1139A — ACCESSIBLE DRINKING FOUNTAINS
- Section 1140A — ACCESSIBLE TELEPHONES
- Section 1141A — ACCESSIBLE SWIMMING POOLS
- Section 1142A — ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIG…
- Section 1143A — SIGNAGE
- Section 1144A — RESERVED
- Section 1145A — RESERVED
- Section 1146A — RESERVED
- Section 1147A — RESERVED
- Section 1148A — RESERVED
- Section 1149A — RESERVED
- Section 1150A — SITE IMPRACTICALITY TESTS
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
- Chapter 12 — INTERIOR ENVIRONMENT
- Chapter 13 — ENERGY EFFICIENCY
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 17A — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 18A — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 19A — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 21A — MASONRY
- Chapter 22 — STEEL
- Chapter 22A — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 29 — PLUMBING SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31A — SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING…
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 34 — RESERVED
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U—AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix E — RESERVED
- Appendix F — RODENTPROOFING
- Appendix G — FLOOD-RESISTANT CONSTRUCTION
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED B…
- Appendix L — EARTHQUAKE RECORDING INSTRUMENTATION
- Appendix M — TSUNAMI-GENERATED FLOOD HAZARDS
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — PERFORMANCE-BASED APPLICATION
- Appendix P — SLEEPING LOFTS
- Appendix Q — EMERGENCY HOUSING