How are definitions organized alphabetically and by section groups?
The CMC lists definitions alphabetically by the term’s first word and groups them under letter headings (for example, the A block at § 203.0). To find a definition, go to the letter matching the first word and scan the alphabetical list there; ordinary words are not redefined unless the code says so (see § 201.1).
Last reviewed: July 6, 2026
What the code requires — 2-4 sentences
The California Mechanical Code requires that the chapter of defined terms be organized so that the definitions of terms are arranged alphabetically according to the first word of the term — this is the governing rule in § 202.1 of the CMC. The chapter is then presented in letter-group sections (for example, § 203.0 — A — contains all entries that begin with the letter A) so a user looks to the letter heading and then to the alphabetical listing under that heading. See § 202.1 and the start of the A‑group at § 203.0 for the controlling layout language.
The most important rule: look up a defined term by the term’s first word — definitions are listed alphabetically by the first word and collected under letter headings (A, B, C …).
Requirements in detail
Basic organization
- The definitions chapter header and applicability language appear in § 201.0 / § 201.1 (general applicability to the code). The explicit rule about ordering is in § 202.1: alphabetical according to the first word of the term. The actual letter group headings (for example – A –) start at § 203.0 and contain the entries beginning with that letter.
- Practically that means:
- Find the letter heading for the initial letter of the term (A, B, C …) — e.g., § 203.0 — A — contains “Absorption Unit,” “Access Panel,” “Accessible,” etc.
- Within the letter block, entries are sorted alphabetically by the term’s first word (not by subsequent words, punctuation, or the intent of the phrase).
Entry format and display conventions
- Each definition entry shows the term followed by its definition text; many entries include bracketed references to other standards. Example entries under the A block in § 203.0 show this format (e.g., Absorption Unit, Access Panel, Accessible).
- Commas and parenthetical modifiers are part of the entry text (e.g., Air, Class 1) — the “first word” rule still applies (such entries will be located under the letter “A”).
Decision table — how to look up and how the code controls it
| Decision dimension | Values / outcomes | How it affects a lookup | Code Reference |
|---|---|---|---|
| Sorting key | First word of the term | Use the first word to pick the letter block and determine order | § 202.1 |
| Letter grouping | A, B, C … (letter blocks) | Go to the letter heading (e.g., § 203.0 — A —) for words starting with that letter | § 203.0 |
| Ordinary words | Not separately defined unless needed | Ordinary dictionary meanings are presumed unless a code definition exists | § 201.1 |
| Cross‑code definitions | (see exceptions) | If an applicable term is defined elsewhere, check the other code — (not fully shown in the retrieved CMC text; see Exceptions) | retrieval note below |
Practical indexing notes (from the code structure)
- Letter headers (e.g., – A –) act as primary navigational anchors in Chapter 2; the listing under each header flows in alphabetical order by first word.
- Multi‑word terms are not reindexed by their second word (so “Air, Conditioned” and “Conditioned Air” are not the same lookup — use the entry’s first word).
Exceptions & special cases
- Ordinary common‑use words are intentionally left undefined when the ordinary dictionary meaning suffices — the CMC states no attempt is made to define ordinary words unless necessary; see § 201.1.
- The retrieved copy of the CMC that we used clearly shows the alphabetical rule at § 202.1 and the A‑group at § 203.0, and shows the applicability language in § 201.1. The retrieved CMC text does not, in the snippets shown to me, explicitly reproduce a § 201.3 text about terms defined in other codes. (Several other California codes do include a § 201.3 that says terms defined in other California codes take those meanings; that language is present in the Fire Code and other titles in the files provided, but the CMC snippet I used does not show an explicit § 201.3 entry.) If you need the cross‑code rule specifically for the CMC, I can fetch and cite the exact CMC § 201.3 text if you want.
Common mistakes
- Sorting by the second word (for example, treating “Air, Conditioned” as under “Conditioned”) — the CMC requires sorting by the first word.
- Overlooking letter headings — users sometimes flip straight to a random page instead of going to the letter block that matches the term’s first word (e.g., missing § 203.0 — A —).
- Ignoring punctuation or small modifiers — entries like Air, Class 1 are listed under “A”; do not search under “Class.”
- Assuming every commonly used word is defined — the code explicitly does not redefine ordinary dictionary words unless necessary (see § 201.1).
Worked example — concrete scenario applying the rule with numbers
Scenario: you need to find these three terms in the CMC definitions:
- Absorption Unit
- Access Panel
- Air, Class 1
Step 1 — determine the first word of each term:
- Term 1 first word = Absorption
- Term 2 first word = Access
- Term 3 first word = Air
Step 2 — go to the letter block for “A” (the A block is started at § 203.0 — A —).
Step 3 — within the A block, sort alphabetically by the first word:
- Absorption Unit (Absorption …) — appears before
- Access Panel (Access …) — appears next
- Air, Class 1 (Air …) — appears after Access entries, among other “Air” entries
Result (example ordered list you will find under § 203.0 — A —):
- Absorption Unit
- Accepted Engineering Practice (example shown in the code)
- Access Panel
- Accessible
- Air, Class 1
(Actual neighboring entries are shown in the CMC A‑block.)
This ordering is driven by the rule in § 202.1 and the A‑group structure in § 203.0.
Related provisions
- § 201.0 — General (Chapter 2 header and context for definitions)
- § 201.1 — Applicability; approach to ordinary words (ordinary words not redefined unless needed)
- § 202.0 — Definition of Terms (heading for definition section)
- § 202.1 — General: alphabetical ordering rule (controlling requirement)
- § 203.0 — Letter group start (example: – A – block showing A entries)
Code references
Grounded in the retrieved California Mechanical Code — click a citation to read the verbatim passage:
CMC § 201.0 High relevance — show source text
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
30 2025 CALIFORNIA MECHANICAL CODE
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
CHAPTER 2
DEFINITIONS
201.0 General.
201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter.
No attempt is made to define ordinary words, which are used in accordance with their established dictionary meanings, except where a word has been used loosely, and it is necessary to define its meaning as used in this code to avoid misunderstanding.
202.0 Definition of Terms.
202.1 General. The definitions of terms are arranged alphabetically according to the first word of the term.
203.0 – A –
Absorption Unit. An absorption refrigeration system that has been factory-assembled and tested prior to its installation.
Accepted Engineering Practice. That which conforms to technical or scientific-based principles, test, or standards that are accepted by the engineering profession.
Access Panel. A closure device used to cover an opening into a duct, an enclosure, equipment, or an appurtenance.
[NFPA 96:3.3.1]
Accessible. Where applied to a device, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction.
Accessible, Readily. Having a direct access without the necessity of removing a panel, door, or similar obstruction.
Accessory Dwelling Unit. [HCD 1 & HCD 2] An attached or detached residential dwelling unit that provides complete independent living facilities for one or more persons and is located on a lot with a proposed or existing primary residence. Accessory dwelling units shall include permanent provisions for living, sleeping, eating, cooking, and sanitation on the same parcel as the single-family or multifamily dwelling is or will be situated. (See Government Code Section 65852.2.)
Air, Class 1. Air with low contaminant concentration, low sensory-irritation intensity, and inoffensive odor. [ASHRAE 62.1:5.18.1]
Air, Class 2. Air with moderate contaminant concentration, mild sensory-irritation intensity, or mildly offensive odors. Class 2 air also includes air that is not necessarily harmful or objectionable, but that is inappropriate for transfer or recirculation to spaces used for different purposes. [ASHRAE 62.1:5.18.1]
Air, Class 3. Air with significant contaminant concentration, significant sensory-irritation intensity, or offensive odor.
[ASHRAE 62.1:5.18.1]
Air, Class 4. Air with highly objectionable fumes or gases or with potentially dangerous particles, bioaerosols, or gases, at concentrations high enough to be considered as harmful.
[ASHRAE 62.1:5.18.1]
Air, Combustion. See Combustion Air.
Air, Conditioned. Air that has been treated to achieve a desired level of temperature, humidity, or cleanliness.
CMC § 204.0 High relevance — show source text
0
204.0
206.0
207.0
208.0
209.0
210.0
214.0
215.0
216.0
217.0
222.0
223.0
228.0
|||X|X|X|||||X|X|X|X|X|X|X||||||||| |Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended sections
listed below)
Adopt only those sections
that are listed below
Chapter/Section
203.0
204.0
206.0
207.0
208.0
209.0
210.0
214.0
215.0
216.0
217.0
222.0
223.0
228.0
||||||||||X||X|X|X|X||||||||||This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
2025 CALIFORNIA MECHANICAL CODE 29
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
30 2025 CALIFORNIA MECHANICAL CODE
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
CHAPTER 2
DEFINITIONS
201.0 General.
201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter.
No attempt is made to define ordinary words, which are used in accordance with their established dictionary meanings, except where a word has been used loosely, and it is necessary to define its meaning as used in this code to avoid misunderstanding.
202.0 Definition of Terms.
202.1 General. The definitions of terms are arranged alphabetically according to the first word of the term.
203.0 – A –
Absorption Unit. An absorption refrigeration system that has been factory-assembled and tested prior to its installation.
Accepted Engineering Practice. That which conforms to technical or scientific-based principles, test, or standards that are accepted by the engineering profession.
Access Panel. A closure device used to cover an opening into a duct, an enclosure, equipment, or an appurtenance.
[NFPA 96:3.3.1]
Accessible. Where applied to a device, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction.
Accessible, Readily. Having a direct access without the necessity of removing a panel, door, or similar obstruction.
CMC § 1.11.0. High relevance — show source text
0||||X|||||||||||||||||||||
This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
2025 CALIFORNIA PLUMBING CODE 29
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
30 2025 CALIFORNIA PLUMBING CODE
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
CHAPTER 2
DEFINITIONS
201.0 General.
201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter.
No attempt is made to define ordinary words, which are used in accordance with their established dictionary meanings, except where a word has been used loosely, and it is necessary to define its meaning as used in this code to avoid misunderstanding.
202.0 Definition of Terms.
202.1 General. The definitions of terms are arranged alphabetically according to the first word of the term.
203.0 – A –
ABS. Acrylonitrile-butadiene-styrene. Accepted Engineering Practice. That which conforms to technical or scientific-based principles, tests, or standards that are accepted by the engineering profession. Accessible. Where applied to a fixture, connection, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction. Accessible, Readily. Having a direct access without the necessity of removing a panel, door, or similar obstruction. Accessory Dwelling Unit. [HCD 1 & HCD 2] An attached or detached residential dwelling unit that provides complete independent living facilities for one or more per- sons and is located on a lot with a proposed or existing pri- mary residence. Accessory dwelling units shall include permanent provisions for living, sleeping, eating, cooking, and sanitation on the same parcel as the single-family or mul- tifamily dwelling is or will be situated. (See Government Code Section 65852.2.) Air Break. A physical separation which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected. Air Gap, Drainage. The unobstructed vertical distance through the free atmosphere between the lowest opening from a pipe, plumbing fixture, appliance, or appurtenance conveying waste to the flood-level rim of the receptor. Air Gap, Water Distribution. The unobstructed vertical distance through the free atmosphere between the lowest opening from a pipe or faucet conveying potable water to the flood-level rim of a tank, vat, or fixture.
Alternate Water Source. Nonpotable source of water that includes but not limited to gray water, on-site treated nonpotable water, on-site treated nonpotable gray water, rainwater, and reclaimed (recycled) water. Anchors. See Supports. Anodeless Riser. An assembly of steel-cased plastic pipe used to make the transition between plastic piping installed
underground and metallic piping installed aboveground.
[NFPA 54:3.3.3] **Appliance.
CMC § 211.0 Medium relevance — show source text
0
211.0
214.0
215.0
216.0
217.0
218.0
220.0
221.0
222.0
223.0
225.0||X||X||||||X||X|X|X|X|||||||||| |Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
203.0
204.0
205.0
206.0
207.0
208.0
209.0
210.0
211.0
214.0
215.0
216.0
217.0
218.0
220.0
221.0
222.0
223.0
225.0||||X||||||||||||||X||||||| |Adopting Agency
Adopt Entire Chapter
Adopt Entire Chapter as
amended (amended
sections listed below)
Adopt only those sections
that are listed below
Chapter/Section
203.0
204.0
205.0
206.0
207.0
208.0
209.0
210.0
211.0
214.0
215.0
216.0
217.0
218.0
220.0
221.0
222.0
223.0
225.0||||X|||||||||||||||||||||This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
2025 CALIFORNIA PLUMBING CODE 29
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
30 2025 CALIFORNIA PLUMBING CODE
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
CHAPTER 2
DEFINITIONS
201.0 General.
201.1 Applicability. For the purpose of this code, the following terms have the meanings indicated in this chapter.
No attempt is made to define ordinary words, which are used in accordance with their established dictionary meanings, except where a word has been used loosely, and it is necessary to define its meaning as used in this code to avoid misunderstanding.
202.0 Definition of Terms.
202.1 General. The definitions of terms are arranged alphabetically according to the first word of the term.
203.0 – A –
ABS. Acrylonitrile-butadiene-styrene. Accepted Engineering Practice. That which conforms to technical or scientific-based principles, tests, or standards that are accepted by the engineering profession. Accessible. Where applied to a fixture, connection, appliance, or equipment, “accessible” means having access thereto, but which first may require the removal of an access panel, door, or similar obstruction. **Accessible, Readily.
CMC § 2.1 Medium relevance — show source text
The IBC requirements for hazardous materials, fire-resistance-rated construction, interior finish, fire protection systems, means of egress, emergency and standby power, and temporary structures are directly correlated with the requirements of the International Fire Code ® (IFC®). The following table shows chapters/sections of the IBC that are correlated with the IFC:
IBC/IFC CORRELATED TOPICS Col2 Col3 IBC CHAPTER/SECTION IFC CHAPTER/SECTION SUBJECT Sections 307, 414, 415 Chapters 50–67 Hazardous materials and Group H requirements Chapter 7 Chapter 7 Fire-resistance-rated construction (fire and smoke protection features in the IFC) Chapter 8 Chapter 8 Interior finish, decorative materials and furnishings Chapter 9 Chapter 9 Fire protection systems Chapter 10 Chapter 10 Means of egress Chapter 27 Section 604 Standby and emergency power Section 3103 Chapter 31 Temporary structures Chapter 1 Scope and Administration.
Chapter 1 establishes the limits of applicability of the code and describes how the code is to be applied and enforced. The provisions of Chapter 1 establish the authority and duties of the code official appointed by the authority having jurisdiction and also establish the rights and privileges of the design professional, contractor and property owner.
Chapter 2 Definitions.
Chapter 2 is the repository of the definitions of terms used in the body of the code. The user of the code should be familiar with and consult this chapter because the definitions are essential to the correct interpretation of the code and because the user may not be aware that a term is defined.
xii 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
Chapter 3 Occupancy Classification and Use.
Chapter 3 provides for the classification of buildings, structures and parts thereof based on the purpose for which they are used. Section 302 identifies the groups into which all buildings, structures and parts thereof must be classified. Sections 303 through 312 identify the occupancy characteristics of each group classification. In some sections, specific group classifications having requirements in common are collectively organized such that one term applies to all. For example, Groups A-1, A-2, A-3, A-4 and A-5 are individual groups for assembly-type buildings. The general term “Group A,” however, includes each of these individual groups. Other groups include Business (B), Organized Camps (C), Educational (E), Factory (F-1, F-2), High Hazard (H-1, H-2, H-3, H-4, H-5), Institutional (I-2, I-3, I-4), Laboratories (L), Mercantile (M), Residential (R-1, R-2, R-2.1, R-2.2, R-3, R-3.1, R-4), Storage (S-1, S-2) and Utility (U). In some occupancies, the smaller number means a higher hazard, but that is not always the case.
CMC § 0.15 Medium relevance — show source text
95|0.15 ×TDA + 1.95| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Vertical Closed
Transparent (VCT)|0 (L)|<32|VCT.RC.L|0.49 ×TDA + 2.61|0.49 ×TDA + 2.61| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Horizontal Closed
Transparent (HCT)|38 (M)|≥32|HCT.RC.M|0.16 ×TDA + 0.13|0.16 ×TDA + 0.13| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Horizontal Closed
Transparent (HCT)|0 (L)|<32|HCT.RC.L|0.34 ×TDA + 0.26|0.34 ×TDA + 0.26| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Vertical Closed
Solid (VCS)|38 (M)|≥32|VCS.RC.M|0.10 ×V + 0.26|0.10 ×V + 0.26| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Vertical Closed
Solid (VCS)|0 (L)|<32|VCS.RC.L|0.21 ×V + 0.54|0.21 ×V + 0.54| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Horizontal Closed
Solid (HCS)|38 (M)|≥32|HCS.RC.M|0.10 ×V + 0.26|0.10 ×V + 0.26| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Horizontal Closed
Solid (HCS)|0 (L)|<32|HCS.RC.L|0.21 ×V + 0.54|0.21 ×V + 0.54| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Service Over
Counter (SOC)|38 (M)|≥32|SOC.RC.M|0.44 ×TDA + 0.11|0.44 ×TDA + 0.11| |Remote
condensing com-
mercial refriger-
ators and
commercial
freezers|Remote (RC)|Service Over
Counter (SOC)|0 (L)|<32|SOC.RC.L|0.93 ×TDA + 0.22|0.93 ×TDA + 0.22| |Self-contained
commercial
refrigerators and
commercial
freezers with and
with outdoors|
Self-contained
(SC)|Vertical Open
(VOP)|38 (M)|≥32|VOP.CMC § 2.1 Medium relevance — show source text
xii 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
Chapter 3 Occupancy Classification and Use.
Chapter 3 provides for the classification of buildings, structures and parts thereof based on the purpose for which they are used. Section 302 identifies the groups into which all buildings, structures and parts thereof must be classified. Sections 303 through 312 identify the occupancy characteristics of each group classification. In some sections, specific group classifications having requirements in common are collectively organized such that one term applies to all. For example, Groups A-1, A-2, A-3, A-4 and A-5 are individual groups for assembly-type buildings. The general term “Group A,” however, includes each of these individual groups. Other groups include Business (B), Organized Camps (C), Educational (E), Factory (F-1, F-2), High Hazard (H-1, H-2, H-3, H-4, H-5), Institutional (I-2, I-3, I-4), Laboratories (L), Mercantile (M), Residential (R-1, R-2, R-2.1, R-2.2, R-3, R-3.1, R-4), Storage (S-1, S-2) and Utility (U). In some occupancies, the smaller number means a higher hazard, but that is not always the case.
Defining the use of the buildings is very important as it sets the tone for the remaining chapters of the code. Occupancy works with the height, area and construction type requirements in Chapters 5 and 6, to determine "equivalent risk." The determination of equivalent risk involves three interdependent considerations: (1) the level of fire hazard associated with the specific occupancy of the facility; (2) the reduction of fire hazard based on the fuel load by limiting the floor area and the height of the building; and (3) the level of overall fire resistance provided by the type of construction. The greater the potential fire hazards indicated as a function of the group, the lesser the height and area allowances for a particular construction type.
Occupancy classification also plays a key part in the appropriate protection measures. As such, threshold requirements for fire protection and means of egress systems are based on occupancy classification (see Chapters 9 and 10). Other sections of the code also contain requirements respective to the classification of building groups. For example, Section 706 specifies requirements for fire wall fire-resistance ratings that are tied to the occupancy classification of a building and Section 803.11 contains interior finish requirements that are dependent upon the occupancy classification. The use of the space, rather than the occupancy of the building, is utilized for determining occupant loading (Section 1004) and live loading (Section 1607).
Chapter 4 Special Detailed Requirements Based on Occupancy and Use.
Chapter 4 contains the requirements for protecting special uses and occupancies which are supplemental to the remainder of the code. For example, the height and area limitations established in Chapter 5 apply to all special occupancies unless Chapter 4 contains height and area limitations. In this case, the limitations in Chapter 4 supersede those in other sections. An example of this is the height and area limitations for open parking garages given in Section 406.5.4, which supersede the limitations given in Sections 504 and 506.
CMC § 5303.16.1 Medium relevance — show source text
1, 5303.16.1, 5303.16.2, 5306.1, 5306.2, 5306.2.1, 5306.2.2, 5307.4.6, 5503.1.2, 5503.5.2, 5504.2.1.2, 5504.2.2.2, 5505.4.1, 5604.2, Table 5604.5.2(3), 5605.5, 5701.3, 5704.2.7.7, 5704.2.8.1, 5704.2.8.2, 5704.2.9.3, 5704.2.9.4, 5704.3.3.5, 5704.3.7.1, 5704.3.8, 5705.3.4, 5705.3.5.3, 5705.3.7.1, 5705.3.7.2, 5705.3.7.3, 5705.3.7.4, 5705.3.7.5.1, 5706.2.3, 5706.4.1, 5803.1.1, 5806.4.3, 5808.1, 5808.3, 5808.3.2, 5906.2.2, 5906.2.3, 5906.4.2, 6003.1.4.2, 6005.3.1, 6109.11.2, 6204.1.2, 6306.4, 6404.1.4, 6604.1
CEBC—25: California Existing Building Code
102.3, 1011.5.2, 1103.1, 1104.18, 1105.5.2
CMC—25: California Mechanical Code
201.3, 308.3, 605.1, 605.2.1.1, 605.2.1.2, 605.2.1.3, 605.2.1.4, 605.2.1.5, 605.3, 605.4, 605.4.2.3, 605.4.2.5, 605.5.2, 605.7, 606.1, 606.2, 608.1, 608.3, 608.4, 608.5, 608.8, 608.9.1, 608.10, 608.17, 610.1.1, 903.2.11.4, 904.14, 907.3.1, 909.1, 909.10.2, 909.13.1, 910.4.7, 915.6.1, 1006.2.2.3, 1011.16, 1020.6.1, 1207.4.7, 1207.6.1, 1207.6.1.2.2, 1207.11.8, 2104.2.1, 2105.3, 2301.1, 2301.6, 2309.3.1.2, 2311.3.1, 2311.4.3, 2311.8.2, 2311.
CMC § 1005.7 Medium relevance — show source text
Doors 1005.7, 1006.2, 1007, 1010,
1022.2
Intervening spaces 1016.2 Ramps 1019 Seating at tables 1030.13.1 Single exit 1006.2, 1006.3.3 Stairways 1019 Exit Discharge 202, 1023.12.1, 1023.3, 1024.4, 1028, 1029 Barriers 1023.8
Courts 1029
Horizontal exits 1028.2
Lobbies 1028.2 Public way 1028.5 Termination 1023.3
Vestibule 1028.2 Expanded Plastic Figure 3203.9(1), Figure 3203.9(2) Defined 202 Expanded Vinyl Wall or Ceiling Coverings 803.7, 803.8 Explosion Defined 202 Explosion Control 911, 2204.1, 2803.2, 2803.2.1, 2905.4, 5004.6, 5005.2.1.2, 5005.2.2.2, 5704.2.5, 5705.3.7.5.2, 5705.3.7.6.2, 5808.6, 6204.1.10, 6304.1.1,
6704.1.6 Explosive Material Chapter 56 Buildings under construction or demolition 3308
Defined 202 Explosives and Fireworks Chapter 56 Defined 202 Manufacture, assembly and testing 5605
Permits 105.5.16 Temporary storage of consumer fireworks 5609
Extension Cords 603.6
Exterior Area for Assisted Rescue (see Accessible Means Of Egress) 1009.2, 1009.7 Signage 1009.10, 1009.11, 1009.9 Exterior Wall
Defined 202 Extinguishers (see Fire Extinguishers, Portable) Extra-High-Rack Combustible Storage Approval 3208.5 Defined 202
Fire protection 3208.5.1
Fabrication Area 2705.2
Construction 2703.3.1
Defined 202 Electrical wiring and equipment 2703.7.1
Existing 2701.4 Gas detection 2703.13.1.1
Storage 2704.2 Facility Defined 202 Factory Occupancy (Group F) 203 Alarms and detection 907.2.4 Means of egress Aisles 1018.5
Dead-end corridors 1020.5
Stairways, exit access 1019 Travel distance 1006.2, 1006.3, 1017.2, 1017.2.2 Sprinkler protection 903.2.4 Fail-Safe 5003.2.2.1, 5004.7.2, 5005.1.5.1, 5005.1.11, 6004.2.2.7, 6204.1.11.1 Defined 202
Fairs 105.5.5
Fallout Area
Defined 202
False Alarm
Defined 202
CMC § 1207.7.1 Medium relevance — show source text
202 Battery System, Stationary Storage 1207 Dedicated-use buildings 1207.7.1 Defined 202
Explosion control 1207.6.3 Fire-resistance-rated
separations 1207.7.4 Group R-3 and R-4 occupancies 1207.11 Indoor installations 1207.7 Nondedicated-use buildings 1207.7.2 Outdoor installations 1207.8
Permit 105.5.14, 105.6.6 Signage 1207.4.8 Special installations 1207.9 Spill control and neutralization 1207.6.2
Ventilation 1207.6.1
Battery Types Flow 202
Lead acid 202 Lithium metal polymer 202 Lithium-ion 202
Nickel cadmium 202
Stationary storage 202 Bin Box 3208.1
Defined 202 Biofuel, Solid (see Solid Biofuel) Biomass Feedstock, Solid (see Solid Biomass Feedstock) Bleachers 202 Means of egress 1030.1.1, 1030.17 Occupant load 1004.4 Separation 903.2.1.5.1, 1030.1.1.1 Board of Appeals Appendix A Boarding House (Occupancy Group R) 203
Bond For explosives 5601.2.4.1 For fireworks display 5601.2.4.2 Bonding and Grounding 2104.2.4, 2106.3.4 Aircraft fueling 2006.3.7.1, 2006.5.2
CNG motor fuel-dispensing facilities 2308.8.1.2.4 Cryogenic fluids 5503.6.2 Organic coating 2904.3 Piping, valves and fittings 5706.4.7.6 Powdered coating 2406.6.4 Roll-coating operations 2405.11 Underground tanks 5706.6.1.8 Vessels 5705.3.2 Bonfires 202, 307.4.1 Permit 105.5.36, 307.2 Breakaway Protection (see Emergency Breakaway Devices) Breakout 202, 1010.3 Breathing Apparatus 2603.3.2 Bridges (see Access Roads, Fire Apparatus) Building 202 Unsafe 115 Vacant (see Vacant Premises) Building Information Card 508.1.6 Building Information Sign Appendix J Building Official 202, 403.10.1.4, 510.1, 3105.2, 3105.4 Duties and powers 104 Building Services and Systems Chapter 6 Bulk Oxygen System 202, Chapter 63 Bulk Plant or Terminal 5706.4
Defined 202
Bulk Transfer 202, 5706.5 Burning (see Open Burning) Business Occupancy (Group B) 203 Alarms and detection 907.2.2 Means of egress Aisles 1018.3
Stairways, exit access 1019 Travel distance 1006.2.1, 1006.3,
1017.2
CMC § 1224.3 Medium relevance — show source text
1224.3 Definitions. Specific terms and definitions are provided to facilitate consistency in the interpretation and application of these requirements. Some of these terms may have a broader definition in other contexts, but the definitions provided here reflect the use of the terms for OSHPD requirements.
AIR CONDITIONING. The process or system by which simultaneously the temperature, humidity, air motion and quality are maintained within required limits.
AIRBORNE INFECTION ISOLATION ROOM. A single-occupancy patient room where environmental factors are controlled in an effort to minimize the transmission of those infectious agents usually spread from person to person by droplet nuclei associated with coughing and inhalation.
AMBULATORY CARE. A defined health care encounter(s) of less than 24 hours in duration that requires direct professional health care support within a specific facility.
AMBULATORY SURGICAL FACILITY. Any surgical facility organized for the purpose of providing procedural, invasive surgical care to patients with the expectation that they will be recovered sufficiently to be discharged in less than a 24-hour period.
ANGIOGRAPHY. The radiographic visualization of blood vessels following introduction of contrast material for purposes of diagnosis.
BASIC SERVICES. Those essential services required for licensure as a hospital, including medical, nursing, surgical, anesthesia, labora- tory, radiology, pharmacy, dietary services and support services. See “SUPPLEMENTAL SERVICES.”
BIOTERRORISM. The use or threat of use, of biological agents to intimidate a political entity or population group.
CENTRAL AIR-HANDLING SYSTEMS. Any units requiring ductwork on the supply or inlet side and serving more than one room.
CHANGE IN FUNCTION. A change in function is a change in activity, service or licensed service provided, within the project limits, that does not necessarily change the use, specific use and/or occupancy. Conversion of a space that results in a change in activity such that the space will be required to satisfy the functional requirements under a different code sub-section than that of the prior use is consid- ered a change in function.
CLEAR DIMENSION. An unobstructed room dimension exclusive of built-in casework and equipment and available for functional use.
COURT. An open exterior space bounded on three or more sides by the walls of a structure.
ENVIRONMENT OF CARE. Those features in a built health care entity that are created, structured and maintained to support quality health care.
EXAM ROOM. A room with a bed, stretcher or examination table and capability for periodic monitoring (e.g., measurement of blood pres- sure or pulse oximetry) in which procedures that do not require a specialized suite can be performed (e.g., pelvic examination, blood transfusion).
FLOOR AREA, CLEAR. The actual occupied area exclusive of fixed or wall-mounted cabinets, fixed beds and furnishings, built-in shelves, toilet rooms, closets, lockers, wardrobes, alcoves, anterooms or vestibules.
GENERAL ACUTE-CARE HOSPITAL. A hospital, licensed by the California Department of Public Health, having a duly constituted govern- ing body with overall administrative and professional responsibility and an organized medical staff which provides 24-hour inpatient care, including the basic services.
CMC § 90.1 Medium relevance — show source text
[ASHRAE 90.1: TABLE 6.4.3.4.3]
Col1 OUTDOOR AIR INTAKE (CFM/ft2) Col3 EXHAUST/RELIEF (CFM/ft2) Col5 CLIMATE ZONE NONMOTORIZED1 MOTORIZED NONMOTORIZED3 MOTORIZED 0, 1, 2 0, 1, 2 0, 1, 2 0, 1, 2 0, 1, 2 Any height 20 4 20 4 3 3 3 3 3 Any height 20 10 20 10 4, 5B, 5C 4, 5B, 5C 4, 5B, 5C 4, 5B, 5C 4, 5B, 5C Fewer than three stories 204 10 20 10 Three or more stories 204 10 204 10 5A, 6, 7, 8 5A, 6, 7, 8 5A, 6, 7, 8 5A, 6, 7, 8 5A, 6, 7, 8 Fewer than three stories 204 4 20 4 Three or more stories 204 4 204 4 For SI units: 1 square foot = 0.0929 m [2], 1 cubic foot per minute = 0.00047 m [3] /s, 1 cubic foot per minute = 0.4719 L/s, 1 cubic foot per minute per square foot = 5.08 [(L/s)/m [2] ], 1 inch water gauge = 0.249 kPa
Notes:
1 When tested in accordance with AMCA 500D.
2 Dampers smaller than 12 inches (305 mm) in height, width, or diameter need not be tested but shall be of the same design and construction as the smallest tested damper meeting the listed leakage rate requirement.
3 Nonmotorized dampers smaller than 24 inches (610 mm) in height, width, or diameter shall be permitted to have a leakage rate of 40 CFM/ft 2 [0.203 (m 3 /s)/m 2 ].
4 Where permitted by Section E 503.4.6.4.1, exception 2.
2025 CALIFORNIA MECHANICAL CODE 425
), Copyright © 2025 IAPMO, and may not be used for any other purpose or distributed to any other persons or parties.
APPENDIX E
(2) Systems serving zones where humidity levels are required to be maintained with precision of not more than ±5 percent relative humidity to comply with applicable codes or accreditation standards or as approved by the Authority Having Jurisdiction.
[ASHRAE 90.1:6.4.3.6.2]
CMC § 203.7.3 Medium relevance — show source text
Title 19, Division 1]||||X|||||||||||||||||||| |Chapter / Section|||||||||||||||||||||||| |203.7.3|||X||||||||||||||||||||| |203.7.3.6 - 203.7.3.8|||X||||||||||||||||||||| |203.7.4|||X||||||||||||||||||||| |203.7.4.1|||X||||||||||||||||||||| |203.9.1|||X||||||||||||||||||||| |203.9.2|||X||||||||||||||||||||| |203.9.2.1|||X||||||||||||||||||||| |203.9.2.2|||X||||||||||||||||||||| |203.9.3|||X||||||||||||||||||||| |203.9.3.3|||X||||||||||||||||||||| |203.9.4|||X||||||||||||||||||||| |203.12|||X||||||||||||||||||||| |203.13|||X|||||||||||||||||||||- The California Code of Regulations (CCR), Title 19, Division 1 provisions that are found in the California Fire Code are a reprint from the current CCR, Title 19, Division 1 text for the code user’s convenience only. The scope, applicability and appeals procedures of CCR, Title 19, Division I remain the same. The state agency does not adopt sections identified by the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2-4 2025 CALIFORNIA FIRE CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purpose of the code. General definitions are located in Section 202 and occupancy classification definitions are located in Section 203.
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the California Building Code, Cali- fornia Mechanical Code or California Plumbing Code, such terms shall have the meanings ascribed to them as in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies. Merriam Webster’s Collegiate Dictionary, 11th Edition, shall be considered as providing ordinarily accepted meanings.
SECTION 202—GENERAL DEFINITIONS
CMC § 2-4 Medium relevance — show source text
2-4 2025 CALIFORNIA FIRE CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purpose of the code. General definitions are located in Section 202 and occupancy classification definitions are located in Section 203.
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the California Building Code, Cali- fornia Mechanical Code or California Plumbing Code, such terms shall have the meanings ascribed to them as in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies. Merriam Webster’s Collegiate Dictionary, 11th Edition, shall be considered as providing ordinarily accepted meanings.
SECTION 202—GENERAL DEFINITIONS
[BG] 24-HOUR BASIS. The actual time that a person is an occupant within a facility for the purpose of receiving care. It shall not include a facility that is open for 24 hours and is capable of providing care to someone visiting the facility during any segment of the 24 hours.
3D PRINTER. A machine used in the additive manufacturing process for fabricating objects through the deposition of a material using a print head, nozzle or other printer technology.
[M] ACCESS (TO). That which enables a device, appliance or equipment to be reached by ready access or by a means that first requires the removal or movement of a panel or similar obstruction [see also “Ready access (to)”].
[BE] ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel from any accessible point in a building or facility to a public way.
[BE] ACCESSIBLE ROUTE. A continuous, unobstructed path that complies with Chapter 11 of the California Building Code .
ACTIVE RF EMITTING DEVICE. Any type of circuit component that requires an AC or DC power source with the ability to electrically control electron flow and/or amplification of RF signal, including but not limited to signal boosters, repeaters, bidirectional amplifiers and fiber-distributed antenna systems.
ADDITIVE MANUFACTURING. A process of joining materials to make objects from 3D model data, usually layer upon layer, sometimes referred to as 3D printing. This code recognizes two types of additive manufacturing:
Industrial additive manufacturing. 3D printing operations that typically utilize combustible powders or metals, an inert gas supply, a combustible dust collection system, or that create a hazardous (classified) location area or zone outside the equipment.
CMC § 201.1 Medium relevance — show source text
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the other California Codes, such terms shall have the meanings ascribed to them in those codes. [OSHPD 1, 1R, 2, 4 & 5] For terms not defined in this chapter, refer to Chapters 6 and 7 of the California Administrative Code, and Chapter 2 of the California Building Code. [DSA-SS & DSA-SS/CC] Definitions of terms given in Section 4-207 or 4-314 of the California Administrative Code govern over those in Section 202.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this chapter, such terms shall have ordinarily accepted meanings such as the context implies.
SECTION 202—GENERAL DEFINITIONS
ACCESSORY DWELLING UNIT. [HCD 1 & HCD 2] An attached or detached residential dwelling unit that provides complete independent living facilities for one or more persons and is located on a lot with a proposed or existing primary residence. Accessory dwelling units shall include permanent provisions for living, sleeping, eating, cooking and sanitation on the same parcel as the single-family or multi- family dwelling is or will be situated. (See Government Code Section 65852.2.)
[A] ADDITION. An extension or increase in floor area, number of stories, or height of a building or structure.
[A] ALTERATION. Any construction or renovation to an existing structure other than a repair or addition.
[BG] AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing or similar care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided or staff has accepted responsibility for care recipients already incapable.
[A] APPROVED. Acceptable to the code official.
Exception: [HCD 1 & HCD 2] “Approved” means meeting the approval of the Enforcing Agency, except as otherwise provided by law, when used in connection with any system, material, type of construction, fixture or appliance as the result of investigations and tests conducted by the agency, or by reason of accepted principles or tests by national authorities, or technical, health, or scientific organi- zations or agencies.
Notes :
1. See Health and Safety Code Section 17920 for “Approved” as applied to residential construction and buildings or struc- tures accessory thereto as referenced in Section 1.8.2. 2. See Health and Safety Code Section 17921.1 for “Approved” as applied to the use of hotplates in residential construction as referenced in Section 1.8.2.
3. See Health and Safety Code Section 19966 for “Approved” as applied to Factory-Built Housing as referenced in Section 1.8.3.2.5.
CMC § 1.11. Medium relevance — show source text
REPAIR|||X|||||||||||||||||||||| |ROOF REPLACEMENT|||X|||||||||||||||||||||| |SPC SEISMIC SEPARATION||||||||||X|X|||||||||||||| |SUBSTANDARD BUILDING||||X|X|||||||||||||||||||| |SUBSTANTIAL STRUCTURAL
DAMAGE||||||||||X|X|||||||||||||| |UNREINFORCED CONCRETE||||||||||X|X|X||X|X|||||||||| |UNREINFORCED MASONRY||||||||||X|X|X||X|X|||||||||| |UNSAFE|||X|X|X|||||||||||||||||||| |VOLUNTARY STRUCTURAL
IMPROVEMENTS||||||||||X|X|X||X|X|||||||||| |WORK AREA|||X||||||||||||||||||||||The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2-2 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purpose of the code.
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the other California Codes, such terms shall have the meanings ascribed to them in those codes. [OSHPD 1, 1R, 2, 4 & 5] For terms not defined in this chapter, refer to Chapters 6 and 7 of the California Administrative Code, and Chapter 2 of the California Building Code. [DSA-SS & DSA-SS/CC] Definitions of terms given in Section 4-207 or 4-314 of the California Administrative Code govern over those in Section 202.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this chapter, such terms shall have ordinarily accepted meanings such as the context implies.
SECTION 202—GENERAL DEFINITIONS
ACCESSORY DWELLING UNIT. [HCD 1 & HCD 2] An attached or detached residential dwelling unit that provides complete independent living facilities for one or more persons and is located on a lot with a proposed or existing primary residence. Accessory dwelling units shall include permanent provisions for living, sleeping, eating, cooking and sanitation on the same parcel as the single-family or multi- family dwelling is or will be situated. (See Government Code Section 65852.2.)
CMC § 201.1 Medium relevance — show source text
Division 1
Section|Gov Code
Section|PRC
Section|HSC
Section| |---|---|---|---|---|---|---|---|---|---|---| |Section|Title|Title|Title|Title|Title|Title|Title|Title|Title|Title| |Chapter 2|Definitions|Definitions|Definitions|Definitions|Definitions|Definitions|Definitions|Definitions|Definitions|Definitions| |201|General|Y||||||||| |201.1|Scope|Y||||||||| |201.2|Interchangeability|Y||||||||| |201.3|Terms defined in
other codes|Y||201.3||||||| |201.4|Terms not defined|Y||||||||| |202|Definitions|Y||||||||| ||Accessory structure|Y||||||||| ||Agriculture (T14)|Y||||1270.01(1)||||| ||Applicable building|Y||702A||||||| ||Approved|Y||||||||| ||Approved agency|Y||||||||| ||Building|Y||||1270.01(c)||||| ||Building (T14)|Y||||||||| ||Building official|Y||||||||| ||Certificate of
completion|Y||||||||| ||Code official|Y||||||||| ||Critical fire weather|Y||||||||| ||Dead-end road (T14)|Y||||1270.01(e)||||| ||Defensible space (T14)|Y||||||||| ||Driveway (T14)|Y||||||||| ||Dwelling|Y||702A||1270.01(i)||||| ||Exterior wall assembly|Y||702A||||||| ||Exterior wall covering|Y||702A||||||| ||Fire chief|Y||||||||| ||Fire code official|Y|||202|||||| ||Fire flow calculation
area|Y||||||||| ||Fire hazard severity
zones|Y||702A|4902.1|||2201||| ||Fire protection plan|Y||702A|4902.1|||||| ||Fire weather|Y||||||||| ||Fire-resistance-rated
construction|Y||||||||| ||Fire-smart vegetation|Y|||4902.1|1271.01||||| ||Flame spread index|Y||||||||| ||Fuel|Y||||||||4291(a)(1)(A)| ||Fuel break_(T14)|Y||||1270.01(n)||||| ||Fuel modification|Y||||||||| ||Fuel mosaic|Y||||||||| ||Fuel-loading|Y||||||||| ||Green belt(T14)|Y||||1270.01(o)||||| ||Greenways (T14)|Y||||1270.01(p)||||| ||Hammerhead/T (T14)|Y||||1270.01(q)||||| ||Hazardous land use
(T14)_|Y||||1270.01(r)||||| ||Hazardous materials|Y||||||||| ||Heavy timber
construction|Y||||||||| ||Ignition-resistant
building material|Y||||||||| ||Local responsibility
area (LRA)|Y||702A|4902.1|||||| ||Log wall construction|Y|||||||||2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE APPENDIX H-25
CMC § 1.5 Medium relevance — show source text
The California Code of Regulations (CCR), Title 14, Division 1.5 provisions that are found in the California Wildland-Urban Interface Code are not listed in the Matrix Adoption Tables as they are not within the State Fire Marshal’s authority to adopt. These provisions are a reprint from the current CCR, Title 14, Division 1.5 text for the code user’s convenience only and are identified in the body of the code by square brackets containing references to applicable Title 14 sections.
2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE 2-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2-2 2025 CALIFORNIA WILDLAND-URBAN INTERFACE CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purpose of the code.
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words stated in the present tense include the future; words stated in the masculine gender include the feminine and neuter; and the singular number includes the plural and the plural the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the California Building Code, Cali- fornia Existing Building Code, California Fire Code, California Electrical Code, California Mechanical Code or California Plumbing Code, such terms shall have the meanings ascribed to them as in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have their ordinarily accepted meanings such as the context implies.
SECTION 202—DEFINITIONS
ACCESSORY STRUCTURE. A building or structure used to shelter or support any material, equipment, chattel or occupancy other than a habitable building.
AGRICULTURE (applicable to CCR, Title 14 provisions only). Land used for agricultural purposes as defined in a Local Jurisdiction's zoning ordinances. [CCR Title 14 §1270.01(a)]
APPLICABLE BUILDING. A building that has residential, commercial, educational, institutional or similar occupancy type use.
[A] APPROVED. Acceptable to the code official.
[A] APPROVED AGENCY. An established and recognized organization that is regularly engaged in conducting tests, furnishing inspection services or furnishing product evaluation or certification where such organization has been approved by the code official.
[A] BUILDING. Any structure intended for supporting or sheltering any occupancy.
BUILDING (applicable to CCR, Title 14 provisions only). Any Structure used or intended for supporting or sheltering any use or Occupancy, except those classified as Utility and Miscellaneous Group U. [CCR Title 14 §1270.01(c)]
CMC § 201.3 Medium relevance — show source text
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the California Building Code, Cali- fornia Existing Building Code, California Fire Code, California Electrical Code, California Mechanical Code or California Plumbing Code, such terms shall have the meanings ascribed to them as in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have their ordinarily accepted meanings such as the context implies.
SECTION 202—DEFINITIONS
ACCESSORY STRUCTURE. A building or structure used to shelter or support any material, equipment, chattel or occupancy other than a habitable building.
AGRICULTURE (applicable to CCR, Title 14 provisions only). Land used for agricultural purposes as defined in a Local Jurisdiction's zoning ordinances. [CCR Title 14 §1270.01(a)]
APPLICABLE BUILDING. A building that has residential, commercial, educational, institutional or similar occupancy type use.
[A] APPROVED. Acceptable to the code official.
[A] APPROVED AGENCY. An established and recognized organization that is regularly engaged in conducting tests, furnishing inspection services or furnishing product evaluation or certification where such organization has been approved by the code official.
[A] BUILDING. Any structure intended for supporting or sheltering any occupancy.
BUILDING (applicable to CCR, Title 14 provisions only). Any Structure used or intended for supporting or sheltering any use or Occupancy, except those classified as Utility and Miscellaneous Group U. [CCR Title 14 §1270.01(c)]
[A] BUILDING OFFICIAL. The officer or other designated authority charged with the administration and enforcement of the California Building Code, or the building official’s duly authorized representative.
CERTIFICATE OF COMPLETION. Written documentation that the project or work for which a permit was issued has been completed in conformance with requirements of this code.
[A] CODE OFFICIAL. The official designated by the jurisdiction to interpret and enforce this code, or the code official’s authorized representative.
CRITICAL FIRE WEATHER. A set of weather conditions (usually a combination of low relative humidity and wind) whose effects on fire behavior make control difficult and threaten firefighter safety.
DEAD-END ROAD (applicable to CCR, Title 14 provisions only). A road that has only one point of vehicular ingress/egress, including cul-de- sacs and roads that loop back on themselves. [CCR Title 14 §1270.01(e)]
DEFENSIBLE SPACE. See Sections 403.1.1 and 601.3.
DRIVEWAY (applicable to CCR, Title 14 provisions only). A vehicular pathway route that serves not more than four (4) Residential Units and any number of noncommercial or nonindustrial Utility or Miscellaneous Group U Buildings. [CCR Title 14 §1270.01(i)]
[BG] DWELLING. A building that contains one or two dwelling units used, intended or designed to be used, rented, leased, let or hired out to be occupied for living purposes.
CMC § 1.11. Medium relevance — show source text
Agency BSC BSC-
CGSFM HCD Col6 Col7 DSA Col9 Col10 OSHPD Col12 Col13 Col14 Col15 Col16 Col17 BSCC DPH AGR DWR CEC CA SL SLC Adopting Agency BSC BSC-
CGSFM 1 2 1/AC AC SS SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6 Adopt Entire Chapter X X Adopt Entire Chapter as
amended (amended
sections listed below)X X X X X X X X Adopt only those sections
that are listed belowX X X X Chapter / Section REROOFING X ROOF COATING X ROOF RECOVER X ROOF REPAIR X ROOF REPLACEMENT X SPC SEISMIC SEPARATION X X SUBSTANDARD BUILDING X X SUBSTANTIAL STRUCTURAL
DAMAGEX X UNREINFORCED CONCRETE X X X X X UNREINFORCED MASONRY X X X X X UNSAFE X X X VOLUNTARY STRUCTURAL
IMPROVEMENTSX X X X X WORK AREA X The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2-2 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purpose of the code.
SECTION 201—GENERAL
CMC § 2-1 Medium relevance — show source text
CHAPTER 2 – DEFINITIONS
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-
CGSFM HCD Col6 Col7 DSA Col9 OSHPD Col11 Col12 Col13 Col14 Col15 BSCC DPH AGR DWR CEC CA SL SLC Adopting agency BSC BSC-
CGSFM 1 2 1/AC AC SS 1 1R 2 3 4 5 5 5 5 5 5 5 5 5 Adopt entire CA chapter X X X Adopt entire chapter as
amended (amended sections
listed below)X X X Adopt only those sections
that are listed belowChapter/Section 201 CALIFORNIA RESIDENTIAL
CODE† † † LOW-RISE
RESIDENTIAL BUILDING† † † PLANTS † † † RESIDENTIAL BUILDING † † † RESILIENT FLOORING † † † The state agency does not adopt sections identified by the following symbol: †.
2025 CALIFORNIA GREEN BUILDING STANDARDS CODE 2-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2-2 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
SECTION 201—GENERAL
201.1 Scope. Unless otherwise stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other documents. Where terms are not defined in this code and are defined in the California Building Stan- dards Code or other referenced documents, such terms shall have the meanings ascribed to them as in those publications.
201.4 Terms not defined. Where terms are not defined as specified in this section, such terms shall have ordinarily accepted meanings such as the context implies.
SECTION 202—DEFINITIONS
CMC § 1-33 Medium relevance — show source text
112 Service Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33
113 Means of Appeals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33
114 Violations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34
115 Stop Work Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34
CHAPTER 2 DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
201 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
202 Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE . . . . .3-1
301 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
302 Occupancy Classification and Use Designation . . . . 3-3
303 Assembly Group A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
304 Business Group B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
305 Educational Group E . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
306 Factory Group F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
307 High-Hazard Group H . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
308 Institutional Group I . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
309 Mercantile Group M. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
310 Residential Group R. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
311 Storage Group S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
312 Utility and Miscellaneous Group U . . . . . . . . . . . . . . 3-18
313 Laboratories Group L [SFM]. . . . . . . . . . . . . . . . . . . . . . .3-19
CMC § 101.2.2 Medium relevance — show source text
CFC—25: California Fire Code
101.2.2, 101.4.2, 301.3.1, 302.2, 307.1, 308.1, 802.2.1, 802.2.3, 803.2.3, 803.4.1.1, 803.4.1.2, 803.4.1.3, 803.4.1.4, 803.4.1.5, 803.4.1.6, Table 804.5.1.1(1), 904.1.5, 1011.6.1.1, 1303.1.2, 1305.2.8.1, 1305.2.14, 1305.2.14.1, 1401.2, 1501.1, 1501.5, 1502.1, 1502.1.1, 1502.2, 1502.3, 1504.1, 1507.1, 1507.2
CMC—25: California Mechanical Code
302.2, 702.7, 807.1, 902.1.1, 1008.1, 1305.2.7.1, 1305.2.8, 1305.2.8.1
CPC—25: California Plumbing Code
302.2, 408.1, 702.7, 1009.1, 1009.2, 1009.3, 1009.5, 1302.1.6, 1503.1
16-4 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
REFERENCED STANDARDS
CRC—25: California Residential Code
101.2, 101.4.1, 104.3.1, 109.3.3, 109.3.10, 302.2, 307.1, 308.1, 401.3, 402.1, 405.2.6, 502.2, 502.3, 502.4, 503.2, 503.3, 503.11, 505.2, 505.3, 507.3, 701.3, 702.4, 702.5, 706.2, 708.1, 805.2, 806.4, 809.1, 906.2, 907.1, 1011.2.1, 1103.1, 1103.2, 1103.3, 1104.1, 1201.4, 1302.1.2, 1302.1.3, 1302.1.3, 1303.1.3, 1401.2, 1402.1, 1402.2, 1402.2.1, 1402.3, 1402.4, 1402.5, 1402.6
ICC 300—2023: ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands
301.1.1, 401.1.1, 1401.1.1
ICC A117.1—2017: Accessible and Usable Buildings and Facilities
CMC § 1.11. Medium relevance — show source text
Way_||||||X|X|||||||||||||||||| |Waiting Room|||X|||||||||||||||||||||| |Walk||||||X|X|||||||||||||||||| |Waterline||||||||||||||||||X||||||| |Wet Bar|||||||X|||||||||||||||||| |Wheelchair||||||X|X|||||||||||||||||| |Wheelchair Space|||||||X|||||||||||||||||| |Winery Caves|||X|||||||||||||||||||||| |Work Area Equipment|||||||X|||||||||||||||||| |Workstation_ (2nd paragraph_
only)|||||||X||||||||||||||||||The state agency does not adopt sections identified by the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2-10 2025 CALIFORNIA BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
2 DEFINITIONS
User notes:
About this chapter: Codes, by their very nature, are technical documents. Every word, term and punctuation mark can add to or change the meaning of a technical requirement. It is necessary to maintain a consensus on the specific meaning of each term contained in the code. Chapter 2 performs this function by stating clearly what specific terms mean for the purposes of the code.
ICC code development note: Code change proposals to sections preceded by the designation [A], [BG] or [BS] will be considered by one of the code development committees meeting during the 2025 (Group B) Code Development Cycle.
SECTION 201—GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the California Energy Code, Califor- nia Existing Building Code, California Fire Code, California Green Building Standards Code, California Electrical Code, California Mechanical Code or California Plumbing Code, such terms shall have the meanings ascribed to them as in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies.
For applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, where terms are not defined through the meth- ods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies. Webster’s Third New International Dictionary of the English Language, Unabridged, shall be considered as providing ordinarily accepted meanings.
SECTION 202—DEFINITIONS
[BG] 24-HOUR BASIS. The actual time that a person is an occupant within a facility for the purpose of receiving care. It shall not include a facility that is open for 24 hours and is capable of providing care to someone visiting the facility during any segment of the 24 hours.
[BS] AAC MASONRY. Masonry made of autoclaved aerated concrete (AAC) units, manufactured without internal reinforcement and bonded together using thin- or thick-bed mortar.
Frequently asked questions
Why does the code sort by the first word rather than the obvious subject?
Because § 202.1 requires alphabetical arrangement by the first word of the term; letter blocks (like § 203.0 — A —) collect entries beginning with that first word, which makes lookups consistent and predictable.
If I can’t find a technical term in the CMC definitions, what should I do?
First check the appropriate letter block (by the term’s first word) as required by § 202.1. If it’s not present, the CMC may rely on ordinary dictionary meaning (see § 201.1). If you suspect the term is defined in another California code, you may need to check the other code’s Chapter 2 (many California codes include guidance about cross‑definitions). The retrieved CMC snippet shows the ordinary‑word rule; cross‑code language was not visible for the CMC in the provided excerpt.
Are entries shown with bracketed references to other standards?
Yes — many entries include bracketed references to standards (e.g., NFPA, ASHRAE) or other authorities as part of the entry text. Those appear inside the definition entries (see example A entries in § 203.0).
Can punctuation (commas, hyphens) change where an entry is listed?
No — punctuation is part of the entry text but does not change the primary rule: look under the letter for the term’s first word and then proceed alphabetically within that block.