Division 8 — SPECIFIC USE DESIGN STANDARDS
Chapter 4 — COMMERCIAL AND INDUSTRIAL
Yucaipa Zoning Code · 2026-06 edition · updated 2026-07-07 · Yucaipa
88.0401 Service Station Setbacks. ¶
(a) Protective pump island canopies shall maintain a setback of five feet from the right-of-way shown on the adopted Master Plan of Highways.
(b) Pump islands, when designed parallel or up to, but not including 30 degrees to the nearest right-of-way, shall maintain a setback of 15 feet from the right-of-way shown on the Transportation Element of the General Plan, adopted Specific Plan, or planning area.
(c) Pump islands, when designed at an angle of 30 degrees or more to the nearest right-of-way, shall maintain a setback of 25 feet from the right-of-way shown on the Transportation Element of the General Plan, Specific Plan, or planning area.
(d) Area lighters shall maintain a setback of one foot from the right-of-way shown on the Transportation Element of the General Plan.
(e) All other structures over four feet in height shall maintain setbacks as required in the street setback section for land use districts or as required by the applicable Specific Plan or planning area.
88.0405 Underground Utility Requirements. ¶
Utility lines, including, but not limited to, electric, telephone, communication, street lighting, and cable television, within or directly serving each new commercial, industrial, or institutional development that, for purposes of this section, includes the construction of a new building or an expansion of an existing building by the lesser of 500 square feet or 10% of the existing building square footage, and/or overhead distribution lines on the perimeter, where such undergrounding would result in the removal of four (4) or more utility poles on the same street, shall be placed
underground. However, an infill project, which for purposes of this section consists of a site no more than 15 acres, completely surrounded by existing development, and where poles along the surrounding frontage have not been undergrounded, is exempt from underground utility requirements for existing poles along the frontage. The developer is responsible for complying with the requirements of this subsection without expense to the City, and he or she shall make
necessary arrangements for the installation of such facilities. (Amended by Ord. 340 § 2, 2016; Ord. 253 § 16, 2006; Ord. 186 § 14, 1998; Ord. 389 § 2, 2020)
88.0420 Commercial and Industrial Transitional Uses. ¶
(a) Any commercial or industrial use which is located on a lot in a commercial or industrial district which abuts a residential, agricultural, or resource conservation district shall adhere to the following standards.
(1) The use shall maintain a setback of 15 feet or that required within the land use district in which the use is located, whichever is greater.
(2) All open facilities or outside storage shall be screened by a manmade or natural barrier(s) sufficient to screen all outside storage. For commercial uses, the barrier(s) shall be sufficient to screen all outside storage and shall be sufficient to attenuate noise levels to 65 dBA/Ldn at the property line.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Yucaipa Zoning Code
- Division 1 — GENERAL PROVISIONS
- Division 2 — REVIEWING AUTHORITIES
- Division 3 — PROCEDURES
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 4 — LAND USES
- Division 6 — PLANNING AREAS
- Division 7 — GENERAL DESIGN STANDARDS
-
▸ Division 8 — SPECIFIC USE DESIGN STANDARDS
Overview- Chapter 1 — SINGLE RESIDENTIAL DESIGN STANDARDS
- Chapter 2 — MULTIPLE RESIDENTIAL DESIGN STANDARDS
- Chapter 3 — MOBILEHOME PARKS
- Chapter 4 — COMMERCIAL AND INDUSTRIAL
- Chapter 5 — PLANNED DEVELOPMENTS
- Chapter 6 — PAROLEE HOMES
- Chapter 7 — SEXUALLY-ORIENTED BUSINESSES
- Chapter 8 — CEMETERY DESIGN STANDARDS
- Chapter 9 — SMALL LOT STANDARDS
- Chapter 10 — WIRELESS TELECOMMUNICATIONS FACILITIES
- Chapter 11 — EMERGENCY SHELTERS
- Chapter 12 — SINGLE ROOM OCCUPANCY FACILITIES
- Chapter 13 — HIGH DENSITY MULTIPLE RESIDENTIAL DESIGN STANDARDS
- Chapter 14 — LARGE RESIDENTIAL CARE FACILITIES
- Chapter 15 — BOARDING HOUSES
- Chapter 16 — BED AND BREAKFAST LODGES
- Chapter 17 — TWO UNIT RESIDENTIAL DEVELOPMENT OR URBAN LOT SPL…
- Chapter 18 — ALCOHOL ESTABLISHMENTS
- Chapter 19 — MASSAGE THERAPY ESTABLISHMENTS
- Division 9 — PLANT PROTECTION AND MANAGEMENT
- Division 10 — SOIL AND WATER CONSERVATION
- Division 11 — PUBLIC FACILITIES FINANCING