Skip to content

Title 9 — BUILDING REGULATIONS

Chapter 3

Tracy Building Code · 2026-07 edition · updated 2026-07-25 · Tracy

Table R301.2(1) is amended to read as follows:

Table R301.2(1)

Climatic and geographic design Criteria

Ground
Snow
Load
Wind design Wind design Seismic
Subject To Damage From Subject To Damage From Winter
Ice Barrier
Flood
Air
Mean
Speed'
(MPH)
Topographic
Efects
Special
wind
region
Wind-
borne
debris
zone
Design
Category
Weathering" Front
line
depth°
Termite' Design
Temp
Underlayment
Required
Hazards Freezing
Index
Annual
Temp
0 110 NO NO NO D1-D2 Negligible NA Very
Heavy
36.6
Deg. F
NO See
note
below
3 Deg F-
Day
60.7
Deg. F
MANUAL J DESIGN CRITERIA"
Elevation Latitude Winter heating Summer cooling Altitude correction
factor
Indoor design
temperature
Design
temperature
cooling
Heating
temperature
diference
140 38 32 94 1.0 70 75 38
Cooling
temperature
diference
Wind velocity
heating
Wind velocity
cooling
Coincident wet
bulb
Daily Range Winter humidity Summer humidity
19 15 7.5 69 38 50% 50%

Note: For flood hazards, refer to Flood Insurance Rate Maps, 2009, published by FEMA. Most of Tracy is in Zone X, outside the 0.1 % annual-chance floodplain. General area lying north of I-205 and small portions at the south edge of Tracy are in the 1% annual chance of 100-year floodplain, and in the 200-year floodplain published by the Department of Water Resources.

Section R319 is amended to read as follows:

R319 Address Identification. New and existing buildings shall be provided and maintained with approved address identification. The identification shall comply with all of the following

1.

Not less than 4" high with a 1/2" stroke width

2.

Located minimum of 6' above grade

3.

Illuminated at night. Illumination shall be either internally or externally at an intensity of 5.0 foot-candles

4.

Numbers shall contrast with the background.

5.

Numbers shall be placed on a portion of the building that is both legible and visible from the street that fronts the property

6.

Numbers shall not be placed on a moveable door and shall not be obstructed from view from the street.

7.

Addresses shall be Arabic numbers or alphabetical letters and conventional in form.

Additionally, where access is by means of a private road and/or the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Where required by the fire code official, address numbers/figures shall be provided in additional approved locations to facilitate emergency response.

Multiple residential units serviced by vehicular access to the rear of the buildings through any driveway, alleyway, or parking lot shall have numbers or addresses placed prior to occupancy on all new buildings as to be plainly visible and legible from the rear access way.

APPENDIX X

Section AX108.2.4 is amended to read as follows:

AX108.2.4 Loft Guards. Loft guards shall be located along the open side of lofts. Loft guards shall not be less than 42 inches (914 mm) in height. Loft guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere 4 inches (102 mm) in diameter.

(Ord. No. 1274, § 8, 11-19-2019; Ord. No. 1335, § 8, 12-6-2022)

9.10.060 - One- and two-family dwellings automatic fire suppression systems.

An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings including all newly installed manufactured homes in accordance with Title 25.

(Ord. No. 1192, § 8, 1-21-2014; Ord. No. 1274, § 9, 11-19-2019; Ord. No. 1335, § 10, 12-6-2022)

Editor's note— Formerly § 9.10.050.

Chapter 9.12 - PLUMBING CODE

Sections:

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Tracy Building Code

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.