§ 16.20.010. International Swimming Pool and Spa Code adopted.

The International Swimming Pool and Spa Code, 2024 Edition as published by the International Code Council, is hereby adopted as the swimming pool and spa code of the city of Stanton.

(Ord. 1164, 9/23/2025)

Exceptions & meaning →

§ 16.20.020. International Swimming Pool and Spa Code amended.

Section [A] 101.1 Title is amended to read as follows:

[A] 101.1 Title. These regulations shall be known as the Swimming Pool and Spa Code of the City of Stanton hereinafter to as "this code."

Section [A] 102.7.1 Application of the International Codes is amended to read as follows:

[A] 102.7.1 Application of the International Codes. Where the International Residential Code is referenced in this code, the provisions of the California Residential Code shall apply to related systems in detached one- and two-family dwellings and townhouses not more than three stories in height. Other related systems shall comply with the applicable California Codes or referenced standard.

Section [A] 105.6 Fees is amended to read as follows:

[A] 105.6 Fees. A permit shall not be valid until the fees prescribed by law have been paid. All fees related to and any permit, work, inspection, violation, plan review or refunds shall be in accordance with Section 109 of the California Building Code.

Section [A] 105.6.2 Fee schedule and [A] 105.6.3 Fee refunds are deleted in their entirety without replacement.

Section [A] 108.2 Membership of board is amended to read as follows:

[A] 108.2 Board of appeals. The Board of Appeals shall consist of members as set forth in Chapter 113.1 of the California Building Code and any amendments of the Stanton Municipal Code.

Section [A] 108.2.1 Qualifications is deleted in its entirety without replacement.

Section 305.2.1 Barrier height and clearances is amended to read as follows:

305.2.1 Barrier height and clearances. Barrier heights and clearances shall be in accordance with all of the following:

1. 1. The top of the barrier shall be not less than 60 inches (1,524 mm) above grade where measured on the side of the barrier that faces away from the pool or spa. Such height shall exist around the entire perimeter of the barrier and for a distance of 3 feet (914 mm) measured horizontally from the outside of the required barrier.

(The remaining language in Section 305.2.1 is to remain and unchanged.)