3905.4 Sources of ignition.

San Jose Municipal Code · 2026-09 edition · updated 2026-09-29 · San Jose

Extraction or post oil processing operations which use flammable gas or

flammable liquids shall comply with Sections 3905.3.1 through 3905.3.2.

3905.4.1 Open flame and sparks. Smoking, open flames, direct fired heating devices, etc. shall be prohibited in areas where flammable vapors exist.

3905.4.2 Electrical equipment. Electrical equipment installed in areas of flammable liquid extractions or post oil processing shall be in accordance with CFC Chapter 50, as amended, and NFPA 70 (NEC).