4.105.1 Adjustments to Rating Requirements for Building Demolition and Density.

Applications subject to the

San Francisco Green Building Code, whereby construction of a new building is proposed within five years of the demolition of a building on the site, where such demolition occurred after the effective date of the Green Building Ordinance - November 3, 2008 - the sustainability requirements for new buildings pursuant to the San Francisco Green Building Code shall be increased as follows:

4.105.1.1 LEED® Projects. For projects attaining a LEED® certification:

(1) Where the building demolished was an historical resource, the required points shall be increased by 10 points.

(2) Where the building demolished was not an historical resource, the required points shall be increased by 6 additional points.

(3) Where the building demolished was not an historical resource and the number of dwellings in the residential portion of the replacement structure are tripled, the required points shall be increased by 5 additional points. 4.105.1.2 GreenPoint Rated Projects. For projects attaining GreenPoint Rated:

(1) Where the building demolished was an historical resource, the required points shall be increased by 25 additional points.

(2) Where the building demolished was not an historical resource, the required points shall be increased by 20 additional points.

(3) Where the building demolished was not an historical resource and the number of dwellings in the residential portion of the replacement structure are tripled, the required points shall be increased by 17 additional points.