Earlier editions: 2022
Chapter 36 — CALIFORNIA RESIDENTIAL CODE (CRC)›Part D — APPLICATION OF ASCE 41-06 TO EVALUATION AND RETROFIT DESIGN
San Francisco Building Inspection Commission Codes § 11.2 Augered Cast-in-Place Piles
San Francisco Building Inspection Commission Codes · 2026-08 edition · updated 2026-09-23 · San Francisco
Cite as: San Francisco Building Inspection Commission Codes § 11.2 · Text as of 2026-09-23
The geotechnical report should address axial and lateral pile capacity, integrity testing requirements (especially in case of loose to medium dense saturated sandy soils and soft clayey soils) using, for example, cross hole sonic logging, cross hole Gamma-Gamma logging, thermal testing, or a combination of these methods, as appropriate, pile load testing, and requirements for an automated data-acquisition system.