16.06.010 2025 California Residential Code adopted and amended.¶
The California Residential Code, 2025 Edition, Title 24, Part 2.5 of the California Code of Regulations, together with those omissions, amendments, exceptions and additions thereto, is adopted and hereby incorporated in this chapter by reference and made a part hereof the same as if fully set forth herein.
Unless superseded and expressly repealed, references in City of Palo Alto forms, documents and regulations to the chapters and sections of the former California Code of Regulations, Title 24, 2019, shall be construed to apply to the corresponding provisions contained within the California Code of Regulations, Title 24, 2025. Ordinance No. 5566 of the City of Palo Alto and all other ordinances or parts of ordinances in conflict herewith are hereby suspended and expressly repealed.
Wherever the phrases "California Residential Code" or "Residential Code" are used in this code or any ordinance of the city, such phrases shall be deemed and construed to refer and apply to the California Residential Code, 2025 Edition, Title 24, Part 2.5 of the California Code of Regulations, as adopted by this chapter.
One copy of the California Residential Code, 2025 Edition, has been filed for use and examination of the public in the Office of the Building Official of the City of Palo Alto.
(Ord. 5676 § 1 (part), 2025)
16.06.015 Local amendments.¶
The provisions of this chapter shall constitute local amendments to the cross-referenced provisions of the California Residential Code, 2025 Edition, and shall be deemed to replace the cross-referenced sections of said Code with the respective provisions set forth in this chapter. Where used in this Chapter 16.06, ellipses shall indicate text of the California Residential Code, 2025 Edition, that has been adopted without amendment but is omitted for brevity.
(Ord. 5676 § 1 (part), 2025)
16.06.020 2025 California Residential Code Appendix Chapters adopted.¶
The following Appendix Chapters of the California Residential Code, 2025 Edition, are adopted and hereby incorporated in this chapter by reference and made a part hereof the same as if fully set forth herein:
A. Appendix BF - Patio Covers
B. Appendix BO - Existing Building and Structures
C. Appendix BG - Sound Transmission
D. Appendix CI - Swimming Pool Safety Act
(Ord. 5676 § 1 (part), 2025)
16.06.030 Cross-references to California Residential Code.¶
The provisions of this chapter contain cross-references to the provisions of the California Residential Code, 2025 Edition, in order to facilitate reference and comparison to those provisions.
(Ord. 5676 § 1 (part), 2025)
16.06.040 Administration of California Residential Code.¶
Chapter 1, Division II of the 2025 California Residential Code is replaced in its entirety by Chapter 1, Division II of the 2025 California Building Code as amended by Palo Alto Municipal Code Chapter 16.04.
(Ord. 5676 § 1 (part), 2025)
16.06.050 Section R202 Definitions.¶
Section R202 of the California Residential Code is amended to include the following definitions:
SUPERFICIAL FLOOR AREA. "Superficial floor area" is the net floor area within the enclosing walls of the room in which the ceiling height is not less than seven feet six inches, excluding built-in equipment such as wardrobes, cabinets, kitchen units, or fixtures which are not readily removable.
(Ord. 5676 § 1 (part), 2025)
16.06.060 Table 301.2 Climatic and Geographic Design Criteria.¶
Table 301.2 of the California Residential Code is amended to read:
TABLE R301.2
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
| GROUND SNOW LOAD | WIND DESIGN | WIND DESIGN | SEISMIC DESIGN CATEGORY | SUBJECT TO DAMAGE FROM | SUBJECT TO DAMAGE FROM | SUBJECT TO DAMAGE FROM |
|---|---|---|---|---|---|---|
| GROUND SNOW LOAD | Speed (mph) | Topographic effects | SEISMIC DESIGN CATEGORY | Weathering | Frost line depth | Termite |
| 0 | 92 | No | D0 thru E | Negligible | 5" | Very High |
| WINTER DESIGN TEMP. (°F) | ICE BARRIER UNDERLAYMENT REQUIRED | FLOOD HAZARDS | AIR FREEZING INDEX | MEAN ANNUAL TEMP. (°F) |
|---|---|---|---|---|
| 40 | No | See Footnotes p thru r | 0 | 55 |
p The of Palo Alto entered National Flood Insurance Program in 1979.
q The effective date of the current Flood Insurance Study and Flood Insurance Rate Map is May 18, 2009.
r The panel numbers and dates of all currently effective FIRMs and FBFMs: 06085CIND0A, 06085C0010H, 06085C0015H through 06085C0019H, 06085C0030H, 06085C0036H, 06085C0038H, 06085C0180H, 06085C0185H (May 18, 2009 for all).
(Ord. 5676 § 1 (part), 2025)
16.06.070 Section R301.2.2.6 Irregular buildings.¶
Section R301.2.2.6 of the California Residential Code is amended as follows:
The seismic provisions of this code shall not be used for structures, or portions thereof, located in Seismic Design Categories C, D0, D1 and D2 and considered to be irregular in accordance with this section. A building or portion of a building shall be considered to be irregular where one or more of the conditions defined in Items 1 through 8 occur. Irregular structures, or irregular portions of structures, shall be designed in accordance with accepted engineering practice to the extent the irregular features affect the performance of the remaining structural system. Where the forces associated with the irregularity are resisted by a structural system designed in accordance with accepted engineering practice, the remainder of the building shall be permitted to be designed using the provisions of this code.
Shear wall or braced wall offsets out of plane. Conditions where exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required.
Lateral Support of roofs and floors. Conditions where a section of floor or roof is not laterally supported by shear walls or braced wall lines on all edges.
Exception: Portions of floors that do not support shear walls, braced wall panels above, or roofs shall be permitted to extend not more than 6 feet (1,829 mm) beyond a shear wall or braced wall line.
Shear wall or braced wall offsets in plane. Conditions where the end of a braced wall panel occurs over an opening in the wall below.
Floor and roof opening. Conditions where an opening in a floor or roof exceeds the lesser of 12 feet (3,658 mm) or 50% of the least floor or roof dimension.
Floor level offset. Conditions where portions of a floor level are vertically offset.
Perpendicular shear wall and wall bracing. Conditions where shear walls and braced wall lines do not occur in two perpendicular directions.
Wall bracing in stories containing masonry or concrete construction. Conditions where stories above grade plane are partially or completely braced by wood wall framing in accordance with Section R602 or cold-formed steel wall framing in accordance with Section R603 include masonry or concrete construction. Where this irregularity applies, the entire story shall be designed in accordance with accepted engineering practice.
Exceptions: Fireplaces, chimneys and masonry veneer in accordance with this code.
- Hillside light-frame construction. Conditions in which all of the following apply:
8.1 The grade slope exceeds 1 unit vertical in 5 units horizontal where averaged across…¶
8.2 The tallest cripple wall clear height exceeds 7 feet (2,134 mm), or where a post…¶
8.3 Of the total plan area below the lowest framed floor, whether open or enclosed,…¶
Where Item 8 is applicable, design in accordance with accepted engineering practice shall be provided for the floor immediately above the cripple walls or post and beam system and all structural elements and connections from this diaphragm down to and including connections to the foundation and design of the foundation to transfer lateral loads from the framing above.
Exception: Light-frame construction in which the lowest framed floor is supported directly on concrete or masonry walls over the full length of all sides except the downhill side of the dwelling need not be considered an irregular dwelling under Item 8.
(Ord. 5676 § 1 (part), 2025)
16.06.075 Section R304.5 Dwelling unit and congregate residence superficial floor area.¶
Section R304.5 of the California Residential Code is added to read:
R304.5 Dwelling unit and congregate residence superficial floor area. Every dwelling unit and congregate residence shall have at least one room which shall have not less than 120 square feet of superficial floor area. Every room which is used for both cooking and living or both living and sleeping purposes shall have not less than 144 square feet of superficial floor area. Every room used for sleeping purposes shall have not less than 70 square feet of superficial floor area. When more than two persons occupy a room used for sleeping purposes the required superficial floor area shall be increased at the rate of 50 square feet for each occupant in excess of two. Guest rooms with cooking shall contain the combined required superficial areas of a sleeping and a kitchen, but not less than 144 square feet. Other habitable rooms shall be not less than 70 square feet.
Notwithstanding any provision of this section, children under the age of six shall not be counted for purposes of determining whether a family with minor children complies with the provisions of this Code.
For the purposes of this section, "superficial floor area" means the net floor area within the enclosing walls of the room in which the ceiling height is not less than seven feet six inches, excluding built-in equipment such as wardrobes, cabinets, kitchen units, or fixtures which are not readily removable.
(Ord. 5676 § 1 (part), 2025)
16.06.080 Section R319.1 Emergency escape and rescue openings.¶
Section R319.1 of the California Residential Code is amended to read:
R319.1 Emergency escape and rescue opening required. Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way.
Exceptions:
- Storm shelters and basements used only to house mechanical equipment not exceeding a total floor area of 200 square feet (18.58 m2)
(Ord. 5676 § 1 (part), 2025)
16.06.090 Section R319.4.2.3 Window well fall protection.¶
Section R319.4.2.3 of the California Residential Code is added to read:
R319.4.2.3 Window well fall protection. Window wells with a vertical depth greater than 30 inches shall have guards on all sides. The guards shall be provided in accordance with Section R321.1. Openings shall comply with Section R321.1.3. Access ladder shall comply with Section R319.4.2.1 and shall extend from the bottom of the well to the top of the guard. Grates or similar barriers shall not be installed over the window well.
(Ord. 5676 § 1 (part), 2025)
16.06.100 Section R319.4.5 Security bars.¶
Section R319.4.5 of the California Residential Code is added to read:
R319.4.5 Security bars. Fire Department plan check review and approval of all security bar submittals shall be required prior to the issuance of a building permit.
(Ord. 5676 § 1 (part), 2025)
16.06.110 Section R309.1.1 Design and installation.¶
Section 309.1.1 of the California Residential Code is amended to read:
R309.1.1 Design and installation. Where allowed, automatic sprinkler systems installed in townhouses shall be installed throughout in accordance with NFPA 13 and state and local standards.
(Ord. 5676 § 1 (part), 2025)
16.06.120 Section R309.2 One and two-family dwellings automatic fire sprinkler systems.¶
Section R309.2 of the California Residential Code is amended to read:
R309.2 One and two-family dwellings automatic fire sprinkler systems. Approved automatic sprinkler systems in new buildings and structures and in existing modified buildings and structures shall be provided in the locations described in this section. Automatic fire sprinklers shall be installed per the requirements set forth in Sections 903.2.1 through 903.2.18 of the California Building Code and as follows, whichever is the more restrictive:
- An automatic sprinkler system shall be provided throughout all new buildings and structures.
Exception: New residential occupancies, buildings or structures that do not exceed 350 square feet of building area and contain no interior plumbing fixtures.
- An automatic sprinkler system shall be provided throughout all existing buildings when modifications are made that create an increase in fire area to more than 3,600 square feet or when the addition is equal to or greater than 50% of the existing building square footage, whichever is more restrictive.
3 An automatic fire sprinkler system is required in basements when any of the following occurs:
a) New basements used for storage, utility, occupancy, or habitable space regardless of size.
b) Existing basements that are altered for the use of storage, utility, occupancy, or habitable space regardless of size.
c) Existing basements expanded by 50% or more.
If the addition or alteration is only the basement, then only the basement is required to be protected by fire sprinklers.
An automatic fire sprinkler system is required when either the roof structure, exterior walls, or combination of both has been removed, altered and/or replaced in at least 50% of the existing structure.
An automatic sprinkler system shall be installed throughout when any change in use or occupancy creating a more hazardous fire/life safety condition, as determined by the Fire Chief.
(Ord. 5676 § 1 (part), 2025)
16.06.130 Section R309.2.1 Design and installation.¶
Section R309.2.1 of the California Residential Code is amended to read as follows:
R309.2.1 Design and installation. Where allowed, automatic sprinkler systems installed in one- and two-family detached dwellings shall be installed throughout in accordance with NFPA 13D and state and local standards. Fire sprinkler protection is required under rear covered patios extending over four feet perpendicular from the exterior of the structure.
(Ord. 5676 § 1 (part), 2025)
16.06.140 Section R309.2.2 NFPA 13D sprinkler systems increase in design requirements.¶
Section R309.2.2 of the California Residential Code is added to read as follows:
Section R309.2.2 NFPA 13D sprinkler systems increase in design requirements. In a higher fire fighting hazardous conditions a four head fire sprinkler calculation and coverage in all closets, bathrooms and attics will be required in Residential and Group U Occupancies as determined by the Fire Code Official in the following conditions:
- Structures located in the High Hazardous Fire Areas.
- Structures where the combined fire area is 3,600 sq ft or larger.
- Structures located 150 ft or greater from the Fire Department access roadways.
- Basements and below grade structures.
(Ord. 5676 § 1 (part), 2025)
16.06.150 Section R309.3 Dwelling unit fire sprinkler systems.¶
Section R309.3 of the California Residential Code is deleted in its entirety and amended as follows:
R309.3 Dwelling unit fire sprinkler systems. Fire sprinkler systems shall be designed and installed in accordance with NFPA 13D, State and local standards.
(Ord. 5676 § 1 (part), 2025)
16.06.160 Section R310.1 Smoke detection and notification.¶
Section R310.1 of the California Residential Code is amended to read:
R310.1 Smoke detection and notification. Listed single- and multiple-station smoke alarms complying with UL 217 shall be installed in accordance with the California Fire Code Sections 907.2.11.1 through 907.2.11.5 and manufacturer’s installation and use instructions.
Smoke alarms and smoke detectors shall be in compliance with this code or subject to the provisions of the Health and Safety Code, they shall also be listed and approved for rapid response to smoldering synthetic materials. All smoke alarms or detectors shall be of the photoelectric type or shall have equivalent detection capabilities in compliance with UL 217.
Exception: A photoelectric smoke alarm or detector shall be installed if located within 20 feet to a kitchen, fireplace or woodburning stove or within five feet of a bathroom.
(Ord. 5676 § 1 (part), 2025)
16.06.170 Section R310.1.3 Smoke alarms or detector end of life replacement.¶
Section R310.1.3 of the California Residential Code is added to read:
R310.1.3 Smoke alarms or detector end of life replacement. Smoke alarms or detectors shall be replaced every ten years or according to the manufacture guidelines, whichever is more restrictive.
(Ord. 5676 § 1 (part), 2025)
16.06.180 Section R311.7.5 Carbon monoxide alarms.¶
Section R311.7.5 of the California Residential Code is added to read:
R311.7.5 Carbon Monoxide alarms or detectors end of life replacement. Carbon monoxide alarms or detectors shall be replaced every ten years or according to the manufacture guidelines, whichever is more restrictive.
(Ord. 5676 § 1 (part), 2025)
16.06.190 Section R308 - Site address.¶
Section R308 of the California Residential Code is amended to read:
R308.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than four inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained.
R308.1.1 Address illumination. Address identification required by Section R308.1 shall be illuminated.
R308.1.2 Address identification size. Address numbers and letters shall be sized as follows:
When the structure is between thirty-six (36) and fifty (50) feet from the road or other emergency means of access, a minimum of one-half inch (0.5") stroke by six inches (6") high is required.
When the structure is fifty (50) or more feet from the road or other emergency means of access, a minimum of one inch (1") stroke by nine inches (9") high is required.
(Ord. 5676 § 1 (part), 2025)
16.06.200 Section R306.1 General (Palo Alto Floor Hazard Regulations).¶
The following paragraph is added to Section R306.1 of the California Residential Code:
Palo Alto Flood Hazard Regulations. Notwithstanding the provisions of this Section R306, all construction or development within a flood hazard area (areas depicted as a Special Flood Hazard Area on Flood Insurance Rate Maps published by the Federal Emergency Management Agency) shall comply with the City of Palo Alto Flood Hazard Regulations (Palo Alto Municipal Code Chapter 16.52). Where discrepancies exist between the requirements of this code and said regulations, the more stringent requirements shall apply.
(Ord. 5676 § 1 (part), 2025)
16.06.210 Reserved.¶
16.06.220 Section R401 General.¶
Section 401 of the California Residential Code is amended to read:
R401.1 - R401.3 {'{'}CRC text not modified{'}'}
R401.4 Soils tests. Exception is added at end of the CRC text as follows:
Exception: Refer to PAMC 16.04.450
R401.4.1 Geotechnical evaluation. When permitted by the building official or designee, in lieu of a complete geotechnical evaluation, the load bearing values in T401.4.1(1) shall be assumed.
T401.4.1(2), R401.4.1.1 - R401.4.2 {'{'}CRC text not modified{'}'}
(Ord. 5676 § 1 (part), 2025)
16.06.225 Section R402.2.1 Materials for concrete.¶
Section 402.2.1 of the California Residential Code is amended to read:
R402.2.1 Materials for concrete. Materials for concrete shall comply with the requirements of Section R608.5.1, as amended by PAMC 16.14.240.
(Ord. 5676 § 1 (part), 2025)
16.06.230 Section R403 Foundation.¶
Section R403 of the California Residential Code is amended as follows:
R403.1 - R403.1.1 {'{'}CRC text not modified{'}'}
R403.1.2 Continuous footing in Seismic Design Categories D0, D1, and D2. Exterior walls of buildings located in Seismic Design Categories D0, D1 and D2 shall be supported by continuous solid or fully grouted masonry or concrete footings. All required interior braced wall panels in buildings located in Seismic Design Categories D0, D1 and D2 shall be supported on continuous foundations.
R403.1.3 Footing and stem wall reinforcing in Seismic Design Categories D0, D1, and D2.Concrete footings located in Seismic Design Categories D0, D1 and D2, as established in Table R301.2(1), shall have not fewer than three No. 4 horizontal bars. One No. 4 horizontal bar shall be installed within 12 inches (305 mm) of the top of the stem wall and two No. 4 horizontal bars shall be located 3 to 4 inches (76 mm to 102 mm) from the bottom of the footing.
R403.1.3.1 Concrete stem walls with concrete footings. In Seismic Design Categories D0, D1 and D2 where a construction joint is created between a concrete footing and a stem wall, not fewer than one No. 4 vertical bar shall be installed at not more than four feet (1,219 mm) on center. The vertical bar shall have a standard hook and extend to the bottom of the footing and shall have support and cover as specified in Section R403.1.3.5.3 and extend not less than 14 inches (357 mm) into the stem wall. Standard hooks shall comply with Section R608.5.4.5. Not fewer than one No. 4 horizontal bar shall be installed within 12 inches (305 mm) of the top of the stem wall and two No. 4 horizontal bars shall be located three to four inches (76 mm to 102 mm) from the bottom of the footing.
R403.1.3.2 Masonry stem walls with concrete footings. In Seismic Design Categories D0, D1 and D2 where a grouted masonry stem wall is supported on a concrete footing, not fewer than one No. 4 vertical bar shall be installed at not more than four feet (1,219 mm) on center. The vertical bar shall have a standard hook and extend to the bottom of the footing and have support and cover as specified in Section R403.1.3.5.3 and extend not less than 14 inches (357 mm) into the stem wall. Standard hooks shall comply with Section R608.5.4.5. Not fewer than one No. 4 horizontal bar shall be installed within 12 inches (305 mm) of the top of the wall and two No. 4 horizontal bars shall be located three to four inches (76 mm to 102 mm) from the bottom of the footing. Masonry stem walls shall be solid grouted.
In Seismic Design Categories D0, D1 and D2 masonry stem walls without solid grout and vertical reinforcing are not permitted.
R403.1.3.3 - R403.1.7.4 {'{'}CRC text not modified{'}'}
R403.1.8 Foundations on expansive soils. Foundations and floor slabs for buildings located on expansive soils shall be designed in accordance with Section 1808.6 or Table 1809.7 of the California Building Code as amended in Municipal Code Section 16.04.470.
R403.1.8.1 {'{'}CRC text not modified{'}'}
(Ord. 5676 § 1 (part), 2025)
16.06.240 Section R404.1.3 Concrete foundation walls.¶
Section 404.1.3 of the California Residential Code is amended to read:
R404.1.3 Concrete Foundation Walls. Concrete foundation walls that support light-frame walls shall be designed and constructed in accordance with the provisions of this section, ACI 318, ACI 332, or PCA 100, as amended by PAMC Section 16.14.240. Concrete foundation walls that support above-grade concrete walls that are within the applicability limits of Section R608.2 shall be designed and constructed in accordance with the provisions of this section, ACI 318, ACI 332, or PCA 100, as amended by PAMC Section 16.14.240. Concrete foundation walls that support above-grade concrete walls that are not within the applicability limits of Section R608.2 shall be designed and constructed in accordance with the provisions of ACI 318, ACI 332, or PCA 100, as amended by PAMC Section 16.14.240. When ACI 318, ACI 332, PCA 100 or the provisions of this section, as amended by PAMC Section 16.14.240 are used to design concrete foundation walls, project drawings, typical details and specifications are not required to bear the seal of the architect or engineer responsible for design, unless otherwise required by the state law of the jurisdiction having authority.
(Ord. 5676 § 1 (part), 2025)
16.06.250 Section R504.3.1 Projections exposed to weather.¶
Section R504.3.1 of the California Residential Code is added to read:
R504.3.1 Projections exposed to weather. Floor projections exposed to the weather and sealed underneath, including but not limited to balconies, landings, decks, and stairs shall be constructed of naturally durable wood, preservative-treated wood, corrosion-resistant (e.g. galvanized) steel, or similar approved materials.
(Ord. 5676 § 1 (part), 2025)
16.06.260 Section R506.1 General.¶
Section R506.1 of the California Residential Code is amended to read:
R506.1 General. Concrete slab-on-ground floors shall be designed and constructed in accordance with the provisions of this section of ACI 332, as amended by PAMC Section 16.14.240. Floors shall be a minimum 3 1/2 inches (89 mm) thick (for expansive soils, see Section R403.1.8). The specified compressive strength of concrete shall be as set forth in Section R402.2.
(Ord. 5676 § 1 (part), 2025)
16.06.270 Section R602.10.4.5 Limits on methods GB and PCP.¶
Section R602.10.4.5 of the California Residential Code is added to read:
R602.10.4.5 Limits on methods GB and PCP. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted for use as an intermittent braced wall panels, but gypsum board is permitted to be installed when required by this section to be placed on the opposite side of the studs form other types of braced wall panel sheathing. In Seismic Design Categories D0, D1, and D2, the use of Method PCP is limited to one-story single-family dwelling and accessory structures.
(Ord. 5676 § 1 (part), 2025)
16.06.280 Table R602.10.3(3) Bracing requirements based on seismic design category.¶
Footnote e to Table R602.10.3(3) is amended to read as follows:
e. In Seismic Design Categories D0, D1 and D2, Method GB is not permitted and PCP is limited to one-story dwellings and accessory structures.
(Ord. 5676 § 1 (part), 2025)
16.06.290 Section R608.5 Materials.¶
Section R608.5 of the California Residential Code is amended to read:
R608.5 Materials. Materials used in the construction of concrete walls shall comply with this section, as amended by PAMC Chapter 16.14.240.
(Ord. 5676 § 1 (part), 2025)
16.06.300 Section R703.8.5.1 Locations.¶
Section R703.8.5.1 of the California Residential Code is added to read:
R703.8.5.1 Locations. Flashing shall be installed at wall and roof intersections, gutters, wherever there is a change in roof slope or direction, and around roof openings. Where flashing is of metal, the metal shall be corrosion resistant with a thickness of not less than 0.019 inches (0.483 mm) (e.g. no. 26 galvanized sheet) and shall be primed and painted.
(Ord. 5676 § 1 (part), 2025)
16.06.310 Reserved.¶
16.06.320 Section R1003.9.2.1 Repairs, replacements and alterations.¶
Section R1003.9.2.1 is added to the California Residential Code to read:
R1003.9.2.1 Repairs, replacements and alterations. When any repair, replacement or alteration to the roof of an existing structure is performed, a spark arrester shall be installed on the existing chimney in accordance with Section R1003.9.2.
(Ord. 5676 § 1 (part), 2025)
16.06.330 Section BO109 Preliminary Meeting.¶
Section BO109 of Appendix BO of the California Residential Code is added to read:
Section BO109.1 General. If a building permit is required at the request of the prospective permit applicant, the building official or his or her designee may meet with the prospective applicant to discuss plans for any proposed work under these provisions prior to the application for the permit. The purpose of this preliminary meeting is for the building official to gain an understanding of the prospective applicant’s intentions for the proposed work, and to determine, together with the prospective applicant, the specific applicability of these provisions.
(Ord. 5676 § 1 (part), 2025)