§ 9-12.801. Compliance requirements.¶
(a) The owner of each building within the scope of this chapter shall, upon service of an order and within the time limits set forth in this chapter, cause a structural analysis to be made of the building by an engineer or architect licensed by the State to practice as such and, if the building does not comply with earthquake standards specified in this chapter, the owner shall cause it to be structurally altered to conform to such standards or shall cause the building to be demolished.
(b) The owner of a building within the scope of this chapter shall comply with the requirements set forth above by submitting to the Building Official for review within the stated time limits:
(1) Within 270 days after service of the order, a structural analysis which is subject to approval by the Building Official and which shall demonstrate that the building meets the minimum requirements of this chapter; or
(2) Within 365 days after service of the order, the structural analysis and plans for structural alterations of the building to comply with this chapter; or
(3) Within 365 days after service of the order, obtain a permit and commence and complete the required demolition; provided, however, that no historical building shall be demolished except in accordance with Chapter 8 of Title 4 of the Ojai Municipal Code.
(c) Within 180 days after plans are submitted to the Building Official, make all corrections to such plans required by the Building Official and obtain his approval thereto.
(d) After plans are submitted and approved by the Building Official, the owner shall obtain a building permit and commence construction within two years from the date of such approval and shall complete the required construction within three years from such approval.
(§ 1, Ord. 678, eff. July 12, 1991)
§ 9-12.802. Administration.¶
(a) Order: Service. The Building Official shall issue an order as provided in this section to the owner of each building within the scope of this chapter. Orders will be issued within 30 days of the effective date of the ordinance codified in this chapter and thereafter as necessary.
(b) Order: Contents. The order shall be in writing and shall be served personally or by certified or registered mail upon the owner as shown on the last equalized assessment roll and upon the person, if any, in apparent charge or control of the building. The order shall specify that the building has been determined by the Building Official to be within the scope of this chapter and, therefore, is required to meet the minimum seismic standards of this chapter. The order shall be accompanied by a copy of Section 9-12.801 of this chapter which sets forth the owner's alternatives and time limits for compliance.
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
BUILDING REGULATIONS
§ 9-12.802
§ 9-12.802
(c) Order: Appeal from. The owner of the building or other aggrieved person may appeal the Building Official's initial determination that the building is within the scope of this chapter to the Board of Appeals. Such appeal shall be filed with the Board of Appeals within 60 days from the service date of the order described in this section. Any such appeal shall be decided by the Board of Appeals no later than 90 days after written notice of such appeal has been filed with the City Clerk and the grounds therefor shall be stated clearly and concisely. Except as otherwise provided herein, or as provided in Sections 105 and 106 of the Uniform Building Code, appeals or requests for modifications from any other determination, order or action by the Building Official pursuant to this chapter shall be controlled by the provisions of Chapter 4 of Title 1 of this Code.
(d) Recordation. At the time that the Building Official serves the aforementioned order, the Building Official shall also record in the office of the County Recorder of Ventura County a certificate stating that the subject building is within the scope of this chapter and is a potentially earthquake hazardous building. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to structurally alter or demolish it where compliance with this chapter has not been demonstrated.
If the building is either demolished, found not to be within the scope of this chapter or is structurally capable of resisting minimum seismic forces required by this chapter as a result of structural alterations or an analysis, the Building Official shall record in the office of the County Recorder of Ventura County a form terminating the status of the subject building as being classified within the scope of this chapter.
- (e) Order: Enforcement. If the owner in charge or control of the subject building fails to comply with any order issued by the Building Official pursuant to this chapter within any of the time limits set forth in Section 9-12.801 of this chapter, the Building Official shall verify that the record owner of the building has been properly served. If the order has been served on the record owner, the Building Official shall order that the entire building be vacated and that the building remain vacated until compliance with such order. If compliance with such order has not been accomplished within 90 days after the date the building has been ordered vacated or such additional time as may have been granted by the Board of Appeals, the Building Official may order its demolition in accordance with the provisions of Section 203 of the Uniform Building Code.
==> picture [401 x 150] intentionally omitted <==
----- Start of picture text -----
TABLE NO. 12-A
HORIZONTAL FORCE FACTOR
CONFIGURATION OF MATERIALS Cp
Roofs with straight or diagonal sheathing and roofing applied 0.6
directly to the sheathing or floors with straight tongue and groove
sheathing
Diaphragm with double or multiple layers of boards with edges 0.83
offset and blocked plywood systems
Wall anchors 0.80
----- End of picture text -----
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
OJAI CODE
§ 9-12.802
§ 9-12.802
==> picture [401 x 143] intentionally omitted <==
----- Start of picture text -----
TABLE NO. 12-B
ALLOWABLE VALUE OF HEIGHT-THICKNESS (H/T) RATIO OF
UNREINFORCED MASONRY WALLS
WALL TYPES H/T
Walls of one-story buildings 21
First-story wall of multi-story building 30
Walls in top story of multi-story buildings 14
All other walls 22
----- End of picture text -----
==> picture [401 x 465] intentionally omitted <==
----- Start of picture text -----
TABLE NO. 12-C
ALLOWABLE VALUES FOR EXISTING MATERIALS
EXISTING MATERIALS OR
CONFIGURATIONS OF MATERIALS1 ALLOWABLE VALUES4
1. Horizontal diaphragms 4
a. Roofs with straight sheathing and roofing applied 100 lbs. per foot for seismic
directly to the sheathing shear
b. Roofs with diagonal sheathing and roofing applied 250 lbs. per foot for seismic
directly to the sheathing shear
c. Floors with straight sheathing and finished wood 100 lbs. per foot for seismic
flooring with board edges offset or perpendicular shear
d. Floors with straight sheathing and finished wood 500 lbs. per foot for seismic
flooring with board edges offset or perpendicular shear
e. Floors with diagonal sheathing and finished wood 600 lbs. per foot for seismic
flooring shear
2. Crosswalls 2, 4
a. Plaster with wood or metal lath Per side: 200 lbs. per foot for seismic
shear
b. Plaster on gypsum lath 175 lbs. per foot for seismic
shear
c. Gypsum wall board, unblocked edges 75 lbs. per foot for seismic
shear
d. Gypsum wall board, blocked edges 125 lbs. per foot for seismic
shear
3. Existing footings, wood framing, structural steel and
reinforced steel
a. Plan concrete footings f′c = 1,500 psi unless otherwise
shown by tests
----- End of picture text -----
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
BUILDING REGULATIONS
§ 9-12.802
§ 9-12.802
==> picture [401 x 175] intentionally omitted <==
----- Start of picture text -----
TABLE NO. 12-C
ALLOWABLE VALUES FOR EXISTING MATERIALS
EXISTING MATERIALS OR
CONFIGURATIONS OF MATERIALS1 ALLOWABLE VALUES4
b. Douglas fir wood Allowable stress same as No. 1
D.F.3
c. Reinforcing steel ft = 18,000 lbs. per square inch
maximum3
d. Structural steel ft = 20,000 lbs. per square inch
maximum3
----- End of picture text -----
Notes:
1 Material must be sound and in good condition.
2 Shear values of these materials may be combined except the total combined value shall not exceed 300 lbs. per foot.
3 Stresses given may be increased for combinations of loads as specified in the Uniform Building Code.
4 A one-third increase in allowable stress is not allowed.
TABLE NO. 12-D4 ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
NEW MATERIALS OR CONFIGURATIONS OF MATERIALS ALLOWABLE VALUES4
- Horizontal diaphragms 4 Plywood sheathing applied directly over existing 225 lbs. per foot straight sheathing with ends of plywood sheets bearing on joists or rafters and edges of plywood located on center of individual sheathing boards 2. Crosswalls a. Plywood sheathing applied directly over wood 1.33 times the value specified in studs. No value shall be given to plywood Table No. 25-K-1 of the Uniform applied over existing plaster or wood sheathing Building Code for shear walls b. Drywall of plaster applied directly over wood 100 percent of the values in Table studs No. 47-I of the Uniform Building Code c. Drywall or plaster applied to sheathing over 50 percent of the values plywood existing wood studs specified in Table No. 46-I of the Uniform Building Code
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA § 9-12.802
OJAI CODE
§ 9-12.802
==> picture [401 x 642] intentionally omitted <==
----- Start of picture text -----
TABLE NO. 12-D4
ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION
WITH EXISTING CONSTRUCTION
NEW MATERIALS OR
CONFIGURATIONS OF MATERIALS ALLOWABLE VALUES4
3. Tension bolts 5
Bolts extending entirely through solid or hollow 1,800 lbs. per bolt for a minimum
unreinforced masonry walls secured with 13″-thick solid wall
bearing plates on far side of a three wythe
minimum wall with at least 30 square inches of
2,3
area.
900 lbs. per bolt for 9″-thick solid
wall
600 lbs. for a minimum 6″-thick
hollow wall
4. Shear bolts 5
Bolts embedded a minimum of eight inches into 133 percent of the values for plain
unreinforced masonry walls. Bolts shall be masonry specified for solid masonry
centered in 2 ½ inch diameter hole with the dry- in Table No. 24-E of the Uniform
pack or non-shrink grout round circumference of Building Code. No values larger than
bolt 1,2,3 those given for ¾-inch bolts shall be
used
5. Combined tension and shear bolts 5,6
a. Through bolts—combined shear and tension
Bolts meeting the above requirements for Tension: Same as for tension bolts.
1,2,3 Shear: Same as for shear bolts
tension bolts and shear bolts
b. Embedded bolts—Combined shear and
tension
Bolts extending to the exterior face of the wall Tension: 1,200 lbs. for a minimum
with a 2 ½ inch round plate under the head and 13″-thick wall. 900 lbs. for 9″-thick
drilled at an angle of 22 ½ degrees to the wall. Shear: Same as for shear bolts
horizontal. Installed as specified for shear bolts.
Allowed for use with solid walls only 1,2,3
6. Infilled walls
Reinforced masonry infilled openings in existing Same as values specified for
unreinforced masonry walls. Provide keys or uneinforced masonry walls
dowels to match reinforcing
Reinforced masonry
7. Masonry piers and walls reinforced per Same as values specified in Section
Chapter 24 2409
----- End of picture text -----
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
BUILDING REGULATIONS
§ 9-12.802
§ 9-12.802
TABLE NO. 12-D4 ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
NEW MATERIALS OR CONFIGURATIONS OF MATERIALS ALLOWABLE VALUES
4
Reinforced concrete 8. Concrete footings, walls and piers reinforced Same as values specified in Chapter as specified in Chapter 26 of the Uniform 26 of the Uniform Building Code Building Code and designed for tributary loads
Notes:
1 Bolts to be tested as specified in Article 4 of this chapter.
2 Bolts to be ½-inch minimum in diameter.
3 Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchors and shear bolt nuts.
4 A one-third increase in allowable stress is not allowed.
5 Proprietary anchors, for concealed anchorage and anchorage of hollow masonry units, may be used with prior arrival by the Building Official.
6 Limited to use on solid walls only.
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
OJAI CODE
§ 9-12.802
§ 9-12.802
==> picture [275 x 408] intentionally omitted <==
(§ 1, Ord. 678, eff. July 12, 1991, as amended by § 12, Ord. 708, eff. April 27, 1995)
Downloaded from https://ecode360.com/OJ4979 on 2026-07-07
City of Ojai, CA
BUILDING REGULATIONS
§ 9-13.101
§ 9-12.802
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Ojai Municipal Code
- Title 1
- Title 2
- Chapter 1 — GENERAL ADMINISTRATION
- Chapter 1 — GENERAL ADMINISTRATION
- Article 2 — City Council
- Article 3 — Unclaimed Property
- Article 4 — Posting of Official Notices
- Article 5
- Chapter 2 — FISCAL ADMINISTRATION
- Article 1 — Parks and Recreation Commission
- Chapter 5 — FINANCE DIRECTOR
- Title 3
- Article 14 — Displaying Vehicles for Sale
- Chapter 1 — EMERGENCY ORGANIZATION
- Chapter 2 — TRAFFIC
- Article 4 — General Traffic Regulations
- Article 6 — Traffic Control Devices
- Article 7
- Article 9 — Stop Signs
- Article 10
- Article 11
- Article 12
- Article 14 — Displaying Vehicles for Sale
- Article 18
- Chapter 3 — POLICE DEPARTMENT
- Chapter 4 — FIRE PREVENTION
- Article 2 — Burning Regulations
- Chapter 9 — PUBLIC SAFETY COMMISSION
- Title 4
- Chapter 18 — GRAFFITI
- Article 7 — Civil Responsibility for Damages for Wrongful Disp…
- Chapter 1 — ADVERTISING MATERIALS
- Chapter 2 — TAXICABS
- Article 1
- Article 2 — Definitions
- Article 4 — Permits
- Article 5 — General Regulations
- Article 6 — Public Health and Sanitation
- Article 8
- Chapter 4 — DANGEROUS WEAPONS
- Chapter 6 — REMOVAL OF ABANDONED, WRECKED, DISMANTLED, OR INOP…
- Chapter 7 — AMBULANCES
- Chapter 8 — HISTORIC PRESERVATION LAW
- Chapter 9
- Chapter 10 — BINGO GAMES
- Chapter 11
- Chapter 12 — ARCADES AND AMUSEMENT MACHINES
- Chapter 13 — ALCOHOLIC BEVERAGES
- Chapter 14 — DRUG PARAPHERNALIA
- Chapter 15 — ABATEMENT OF CLOSED, VACANT, AND INOPERATIVE AUTO…
- Article 1 — Arts Commission
- Article 2
- Article 3 — Murals
- Chapter 17 — OUTDOOR GATHERINGS
- Article 1 — Definitions
- Article 2 — General Provisions
- Article 1 — Declaration of Policy
- Article 3 — Prohibition of Graffiti
- Article 5 — Wrongful Display for Sale
- Article 6 — Wrongful Storage
- Article 7
- Article 9 — Signs Required
- Article 10 — Removal
- Article 11
- Article 13 — Reporting Graffiti
- Article 14 — Criminal Action
- Article 15 — Abatement Procedures
- Chapter 19 — PARADES
- Chapter 24
- Chapter 25 — BEEKEEPING
- Chapter 26 — CANNABIS USE AND CULTIVATION
- Chapter 27
- Title 5
- Chapter 1 — INTEGRATED WASTE MANAGEMENT
- Chapter 2 — MOBILE HOMES AND MOBILE HOME PARKS
- Chapter 3 — SEWER SYSTEM
- Article 3 — Sewer Connections
- Article 4 — Service to Properties Outside the City
- Article 1 — Animal Control Director
- Article 2 — License Tags
- Article 3 — Animal Shelter
- Article 4 — Rabies Control
- Article 5 — Animal Control
- Article 6 — Potentially Dangerous and Vicious Dogs
- Article 7 — Wild Animal Control
- Article 8 — Mandatory Sterilization of Dogs and Cats
- Article 9 — General
- Article 10 — Right to Bodily Liberty for Elephants
- Article 11 — Companion Animal Protection
- Chapter 5 — NORDHOFF CEMETERY
- Chapter 6 — ABATEMENT OF NUISANCES
- Chapter 7 — GROUNDWATER CONSERVATION
- Chapter 8 — REDEVELOPMENT AGENCY
- Chapter 9 — PUBLIC HEALTH PERMITS AND ENFORCEMENT
- Chapter 10 — SMOKING REGULATED OR PROHIBITED
- Chapter 11 — NOISE STANDARDS AND REGULATIONS
- Chapter 12 — STORM WATER QUALITY MANAGEMENT
- Chapter 13 — SINGLE-USE CARRYOUT BAGS
- Chapter 14
- Chapter 15 — SMALL ENGINE REGULATIONS
- Chapter 16 — USE AND SALE OF GLUE TRAPS
- Title 6
- Chapter 1 — BUSINESS LICENSE TAX
- Article 1 — General Provisions
- Article 2 — Business License Tax
- Article 3 — Penalties and Enforcement
- Chapter 2 — PAWNBROKERS AND SECONDHAND DEALERS
- Chapter 3 — PEDDLERS AND CANVASSERS OR SOLICITORS
- Chapter 4 — POOL AND BILLIARD ROOMS
- Chapter 6 — RECREATION HALLS
- Chapter 7 — AMUSEMENT MACHINES AND ARCADES
- Chapter 8
- Title 7
- Article 4
- Article 5 — Provisions for Planting
- Article 6 — Special Provisions for Moving Permits
- Article 7 — Outdoor Dining Permits
- Chapter 2
- Chapter 4 — INFORMAL BID PROCEDURES
- Title 8
- Chapter 3 — UNINHABITED TERRITORY ANNEXATION REQUIREMENTS
- Chapter 1 — TAXATION
- Article 3 — Real Property Transfer Taxes
- Article 5 — Park and Recreational Tax
- Article 6 — Library Special Tax
- Article 7 — Cannabis Business General Tax
- Chapter 2 — SPECIAL FUNDS
- Article 1 — Special Gas Tax Street Improvement Fund
- Article 2 — Sanitation Fund
- Article 3 — Park and Recreational Fund
- Article 4 — Capital Outlay Fund
- Article 5 — Cemetery Fund
- Article 6 — Wastewater Capital Reserve Fund
- Chapter 3 — UNINHABITED TERRITORY ANNEXATION REQUIREMENTS
- Chapter 4 — PURCHASING SYSTEM
- Chapter 5 — STATE VIDEO FRANCHISES
- Title 9
- Chapter 12 — SEISMIC SAFETY
- Article 2 — General Requirements
- Chapter 1 — UNIFORM CODES
- Article 1 — State Building Standards Code
- Article 2 — Administrative Provisions
- Article 4 — California Mechanical Code
- Article 5 — California Existing Building Code
- Article 6 — California Administrative Code
- Article 7 — California Electrical Code
- Article 8 — California Plumbing Code.
- Article 9 — California Fire Code
- Article 10 — California Energy Code
- Article 11 — California Green Building Code
- Article 12 — California Referenced Standards Code
- Article 13
- Chapter 2 — PERMITS
- Chapter 3 — FIRE ZONES
- Chapter 4 — ARCHITECTURAL REVIEW (REPEALED)
- Chapter 5 — HOUSE NUMBERING REGULATIONS
- Chapter 6 — SIGN REGULATIONS (REPEALED)
- Chapter 7 — STREET IMPROVEMENTS
- Chapter 8 — UNDERGROUND UTILITY FACILITIES
- Article 1 — Statutory Authorization, Findings of Fact, Purpose…
- Article 3 — General Provisions
- Article 4
- Article 5 — Provisions for Flood Hazard Reduction
- Article 6
- Article 7 — Amendments
- Chapter 10 — PLANNED DRAINAGE FACILITIES
- Chapter 11 — HILLSIDE EROSION CONTROL
- Article 2 — Requirements and Procedure
- Article 4 — Administration
- Chapter 12 — SEISMIC SAFETY
- Article 1 — General
- Article 2 — General Requirements
- Article 3 — Material Requirements
- Article 4 — Quality Control
- Article 5
- Article 6 — Analysis and Design
- Article 7
- Article 8 — Administrative Provisions
- Chapter 13 — TRANSPORTATION DEMAND MANAGEMENT
- Article 3 — Review of Transit Impacts
- Article 4 — Administrative Provisions
- Chapter 14
- Chapter 15 — VACANT PROPERTY MAINTENANCE, SECURITY AND REGISTR…
- Chapter 16 — ELECTRIC VEHICLE CHARGING STATIONS
- Chapter 17
- Title 10
- Chapter 1 — PLANNING COMMISSION
- Chapter 2 — ZONING REGULATIONS Division 1 PURPOSE AND EFFECT O…
- Article 16
- Chapter 4 — RESIDENTIAL PLANNED DEVELOPMENT (RPD) ZONE
- Chapter 3 — SUBDIVISION REGULATIONS
- Chapter 5 — CONDOMINIUM CONVERSIONS
- Chapter 6 — RESIDENTIAL GROWTH MANAGEMENT PLAN
- Division 1 — RESIDENTIAL GROWTH MANAGEMENT PLAN
- Chapter 7 — TIMESHARE FACILITY REGULATIONS
- Chapter 8 — SCHOOL FACILITIES FEES AND DEDICATIONS
- Chapter 10 — SPECIFIC PLAN FEES Division 1 SPECIFIC PLAN FEES
- Chapter 1 — PLANNING COMMISSION
- Chapter 2 — ZONING REGULATIONS
- Division 1 — PURPOSE AND EFFECT OF ZONING REGULATIONS
- Article 1 — Administrative Provisions
- Division 2 — ZONING DISTRICTS, ALLOWABLE LAND USES AND ZONE SP…
- Article 2 — Zoning Map and Zoning Districts
- Article 3 — Development and Land Use Approval Requirements
- Article 4 — Residential Zoning Districts
- Article 5 — Commercial and Manufacturing Zoning Districts
- Article 6 — Special Purpose Zoning Districts
- Article 7 — Overlay Zoning Districts
- Division 3 — DEVELOPMENTAL AND OPERATIONAL STANDARDS
- Article 8 — Property Development Standards
- Article 9 — Affordable Housing Requirements and Incentives
- Article 10 — Creekside Development Standards
- Article 11 — Hillside Development Standards
- Article 12 — Landscaping Standards
- Article 13 — Nonconforming Uses, Structures, and Parcels
- Article 14 — Parking and Loading Standards
- Article 15 — Recycling Facilities
- Article 16.5 — Exterior Lighting Standards
- Article 17 — Standards for Specific Land Uses
- Division 4 — LAND USE PERMITS AND ADMINISTRATION
- Article 18 — Application Filing and Processing
- Article 19 — Zoning Clearances
- Article 20 — Design Review Permits
- Article 21 — Home Occupation Permits
- Article 22 — Temporary Use Permits
- Article 23 — Planned Development Permits
- Article 24 — Conditional Use Permits
- Article 25 — Minor Variances
- Article 26 — Variances
- Article 27 — Amendments
- Article 28 — Development Agreements
- Article 29 — Public Hearings
- Article 30 — Appeals
- Article 31 — Changes to an Approved Project
- Article 32 — Time Limits and Extensions
- Article 33 — Interpretations
- Article 34 — Revocations and Modifications
- Division 5 — ZONING REGULATIONS DEFINITIONS
- Article 36 — Definitions/Glossary
- Chapter 3 — SUBDIVISION REGULATIONS
- Chapter 4 — RESIDENTIAL PLANNED DEVELOPMENT (RPD) ZONE
- Chapter 5 — CONDOMINIUM CONVERSIONS
- Article 1 — Legislative Findings
- Article 3 — General Provisions
- Chapter 6 — RESIDENTIAL GROWTH MANAGEMENT PLAN
- Article 1 — Historical Background
- Article 2 — Plan's Objectives and Purposes
- Article 3 — Findings
- Article 4 — Applicability
- Article 5 — Definitions
- Article 6 — Maximum Number of Residential Allotments for the C…
- Article 7 — Residential Development Allotment Applications
- Article 8 — Director Evaluation
- Article 9 — Appeals to the City Council
- Article 10 — Review of Progress
- Article 11 — Suspension of Allotments—Constitutionality
- Article 12 — Annexations
- Chapter 7 — TIMESHARE FACILITY REGULATIONS
- Article 1
- Article 5 — Findings of Fact
- Article 6 — Transient Occupancy Tax
- Chapter 8 — SCHOOL FACILITIES FEES AND DEDICATIONS
- Division 1 — SCHOOL FACILITIES FEES AND DEDICATIONS
- Article 3 — Findings of Overcrowding
- Article 4 — Prerequisites for Development Approval
- Article 5 — Use of Fees and Land
- Chapter 9 — IMPACT FEES
- Division 1 — IMPACT FEES
- Article 3 — Impact Fee Procedures
- Chapter 10 — SPECIFIC PLAN FEES
- Article 1 — Applicability
- Article 3 — Annual Review and Amendments.
- Chapter 11 — COMMERCIAL GROWTH MANAGEMENT PLAN
- Article 1 — Applicability
- Article 2 — Number of Allotments for the Construction Year and…
- Article 3 — Development Allotment Applications
- Article 4 — Planning Director Evaluation
- Article 5 — Appeals to the City Council
- Article 6 — Exceptions
- Article 7 — Review of Progress
- Article 8 — Suspension/Increase of Allocations
- Chapter 12 — RESIDENTIAL DENSITY BONUS
- Chapter 13 — IN LIEU PARKING FACILITIES FEE
- Chapter 14 — WIRELESS COMMUNICATION FACILITIES
- Chapter 15 — DEVELOPMENT AGREEMENTS
- Chapter 16 — REPORT OF RESIDENTIAL BUILDING RECORDS
- Title 11
- Chapter 1 — RENT STABILIZATION
- Chapter 2
- Title SR
- § SR.010. General Provisions.
- § SR.020. Administration and Personnel.
- § SR.030. Revenue and Finance.
- § SR.040. Business Licenses, Taxes and Regulations.
- § SR.050. Animals.
- § SR.060. Health and Safety.
- § SR.070. Public Peace, Morals and Welfare.
- § SR.080. Vehicles and Traffic.
- § SR.090. Streets, Sidewalks and Public Places.
- § SR.100. Public Services.
- § SR.110. Buildings and Construction.
- § SR.120. Subdivisions.
- § SR.140. Environment.
- Title OL
- § OL.020. Table 2 Special ordinances not codified but to remai…
- § OL.030. Table 3 Ordinances suspended.
- § OL.040. Table 4 Code comparative table and disposition list.