§ 99.11

Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles

SEC. 99.11.101. SCOPE.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Appendix A4 of the California Green Building Standards Code (CALGreen) is adopted by reference with the following exceptions: CALGreen Section A4.105.2, A4.106.7, Table A4.106.8.3.1, Table A4.106.8.3.2, A4.305.2, A4.403.1, A4.404.1, A4.405.2, A4.405.4, A4.407.1, A4.407.3, A4.407.4, A4.407.5, A4.407.7, A4.602, and Table A4.106.5.1(1) are not adopted; and in lieu, LAMC Sections 99.11.102 and 99.11.602, and Subsections A4.105.2, A4.106.7, A4.405.2, A4.405.4, A4.407.1, A4.407.7, A4.602, and Tables A4.106.5.1(1), A4.106.5.1(2), A4.106.5.1(3), and A4.106.5.1(4) are added or amended as provided in this article.

SEC. 99.11.102. GENERAL.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

This section shall set forth the Residential Voluntary Measures.

A4.105.2. Reuse of Materials. Use salvaged, refurbished or reused materials for a minimum of 2.5% of the total value, based on estimated cost of materials on the project. Materials which can be easily reused include but are not limited to the following:

  1. Light fixtures;

  2. Plumbing fixtures;

  3. Doors and trim;

  4. Masonry (reused masonry may only be used for flatwork);

  5. Electrical devices;

  6. Appliances;

  7. Foundations or portions of foundations.

Note: Reused material must be in compliance with the appropriate California Code of Regulations Title 24 requirements. (Amended by Ord. No. 185,587, Eff. 7/16/18.)

TABLE A4.106.5.1(1)

TIER 1 – LOW RISE RESIDENTIAL

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR
REFLECTANCE
THERMAL
EMITTANCE
3-YEAR AGED SRI
≤ 2 : 12 0.68 0.85 82
> 2 : 12 0.28 0.85 27

TABLE A4.106.5.1(2)

TIER 2 – LOW-RISE RESIDENTIAL

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR
REFLECTANCE
THERMAL
EMITTANCE
3-YEAR AGED SRI
≤ 2 : 12 0.70 0.85 85
> 2 : 12 0.34 0.85 35

TABLE A4.106.5.1(3)

TIER 1 – HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED SRI
REFLECTANCE EMITTANCE
≤ 2 : 12 0.68 0.85 82
> 2 : 12 0.28 0.85 27

TABLE A4.106.5.1(4)

TIER 2 – HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR THERMAL 3-YEAR AGED SRI
REFLECTANCE EMITTANCE
≤ 2 : 12 0.70 0.85 85
> 2 : 12 0.34 0.85 35

A4.106.7. Reduction of Heat Island Effect for Nonroof Areas [N]. (Added by Ord. No. 187,208, Eff. 11/5/21.) Reduce nonroof heat islands for 75% of pathways, patios, driveways, or other paved areas by using one or more of the methods listed.

  1. Use trees or other plantings to provide shade and that mature within 15 years of planting. Trees shall be suitable in mature size and environmental requirements for the site. Tree selection and placement shall consider location and size of areas to be shaded, location of utilities, views from the structure, distance to sidewalks and foundations, overhangs onto adjacent properties and streets, and other infrastructure adjacent to landscaping. In addition, shading shall not cast a shadow, as specified, on any neighboring solar collectors pursuant to Public Resources Code Section 25981, et seq. (Solar Shade Control Act);

  2. Use high albedo materials with an initial solar reflectance value of at least .30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E1918 or C1549;

  3. Use open grid pavement system or pervious or permeable pavement system;

  4. Use solar panel arrays to create a canopy shade system; or

  5. Other methods of reducing heat island effects acceptable to the Department.

A4.405.2. Concrete Floors. 75% of all slab-on-grade and structural concrete slab floors that do not require additional coverings are used including but not limited to stained, natural or stamped concrete floors.

Note: Uncovered floors must still remain durable and maintain any acoustical insulation required elsewhere by the Los Angeles Municipal Code.

A4.405.4. Use of Building Materials from Rapidly Renewable Sources. One or more of the following materials manufactured from rapidly renewable sources or agricultural by-products is used for a minimum of 2.5% of the total value, based on estimated cost of materials on the project:

  1. Insulation;

  2. Bamboo or cork;

  3. Engineered products;

  4. Agricultural based products;

  5. Other products acceptable to the enforcing Department.

Note: The intent of this section is to utilize building materials and products which are typically harvested within a 10-year or shorter cycle.

A4.407.1. Drainage Around Foundations. Where not required by code or ordinance, install foundation and landscape drains which discharge to a dry well, sump, bioswale or other approved on-site location.

A4.407.7. Roof Overhangs. When permitted by the Los Angeles Municipal Code, a permanent overhang or non-retractable awning at least 2 feet in depth is provided at all exterior walls.

SEC. 99.11.602.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Section A4.602 of the CALGreen Code is adopted with amendments to read as follows:

TABLE A4.602

RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST

{'{'} Click here for a printable PDF version of this table {'}'}

FEATURE OR MEASURE LEVELS VERIFICATION S
APPLICA
Mandatory
NT TO SELECT E
MEASURES
Prerequi
LECTIVE
sites and
ENFORCI
VER
Enforcing
NG AGENCY TO
IFICATION ME
Installer or
SPECIFY
THOD
Third

electi

ves 1
Agency
____

Designer
____
Party
Tier 1 Tier 2 All All ____
All
FEATURE OR MEASURE APPLICA LEVELS
NT TO SELECT E
MEASURES
LECTIVE ENFORCI
VER
VERIFICATION
NG AGENCY TO
IFICATION ME
S
SPECIFY
THOD
Mandatory Prerequi
electi
sites and
ves 1
Enforcing
Agency
____
Installer or
Designer
____
Third
Party
____
Tier 1 Tier 2 All All All
PLANNING AND DESIGN
Site Selection
A4.103.1A site which complies with at least one of
the following characteristics is selected:
1. An infill site is selected.
2. A greyfield site is selected.
3. An EPA-recognized Brownfield site is selected.
A4.103.2Facilitate community connectivity by one
of the following methods:
1. Locate project within a 1/4-mile true walking
distance of at least 4 basic services;
2. Locate project within 1/2-mile true walking
distance of at least 7 basic services;
3. Other methods increasing access to additional
resources.
Site Preservation
A4.104.1An individual with oversight responsibility
for the project has participated in an educational
program promoting environmentally friendly design
or development and has provided training or
instruction to appropriate entities.
Deconstruction and Reuse of Existing Materials
A4.105.2Existing buildings are disassembled for
reuse or recycling of building materials. The
proposed structure utilizes at least one of the
following materials which can be easily reused:
1. Light fixtures
2. Plumbing fixtures
3. Doors and trim
4. Masonry (reused for flatwork)
5. Electrical devices
6 Ali
. ppances
7. Foundations or portions of foundations
Site Development
4.106.2A plan is developed and implemented to X

manage storm water drainage during construction.
4.106.3Construction plans shall indicate how site
grading or a drainage system will manage all surface
water flows to keep water from entering buildings.
X

4.106.4.1Provide capability for electric vehicle
charging in one- and two-family dwellings and in
townhouses with attached private garages in
accordance with Section 4.106.4.1.
X
4.106.4.2Provide capability for electric vehicle
charging for multi-family dwellings and
X
hotels/motels in accordance with Sections
4.106.4.2.1 or 4.106.4.2.2 as applicable.
4.106.4.3Provide capability for electric vehicle
charging for existing parking lots or new parking
lots for existing residential buildings in accordance
with Section 4.106.4.3 as applicable.
X
4.106.5Roofing materials shall have a minimum 3-
year aged solar reflectance and thermal emittance or
a minimum 3-year aged Solar Reflectance Index
(SRI) equal to or greater than the values specified in
LAMC Table 4.106.5.
X
4.106.7Reduce nonroof heat islands for 25% of
sidewalks, patios, driveways or other paved areas by
using one or more of the methods listed.
X
A4.106.1Reserved.
A4.106.2.1Soil analysis is performed by a licensed
design professional and the findings utilized in the
structural design of the building.
A4.106.2.2Soil disturbance and erosion are
minimized by at least one of the following:
1. Natural drainage patterns are evaluated and
erosion controls are implemented to minimize
erosion during construction and after occupancy.
2. Site access is accomplished by minimizing the
amount of cut and fill needed to install access
roads and driveways.
3. Underground construction activities are
coordinated to utilize the same trench, minimize
the amount of time the disturbed soil is exposed
and the soil is replaced using accepted
compaction methods.

A4.106.2.3Topsoil shall be protected or saved for
reuse as specified in this section.
Tier 1. Displaced topsoil shall be stockpiled for
reuse in a designated area and covered or protected
X2 X2
from erosion.
Tier 2. The construction area shall be identified and
delineated by fencing or flagging to limit
construction activity to the construction area.
X2

A4.106.3Post-construction landscape designs
accomplish one or more of the following:
1. Areas disrupted during construction are restored
to be consistent with native vegetation species
and patterns.
2. Utilize at least 75% native California or drought
tolerant plant and tree species appropriate for the
climate zone region.
A4.106.4Permeable paving is utilized for the
parking, walking or patio surfaces in compliance
with the following:
Tier 1. Not less than 20% of the total parking,
walking or patio surfaces shall be permeable.
Tier 2. Not less than 30% of the total parking,
walking or patio surfaces shall be permeable.
X2 X2
A4.106.5Roofing materials shall have a minimum
3-year aged solar reflectance and thermal emittance
or a minimum Solar Reflectance Index (SRI) equal
to or greater than the values specified in LAMC
Tables A4.106.5.1(1) and A4.106.5.1(2) for low-rise
residential buildings and LAMC Tables
A4.106.5.1(3) and A4.106.5.1(4) for high-rise
residential buildings.
Low-Rise Residential
Tier 1 roof covering shall meet or exceed the values
contained in LAMC Table A4.106.5.1(1).
Tier 2 roof covering shall meet or exceed the values
contained in LAMC Table A4.106.5.1(2).
High-Rise Residential, Hotels and Motels
Tier 1 roof covering shall meet or exceed the values
contained in LAMC Table A4.106.5.1(3).
X2
X2
X2
Tier 2 roof covering shall meet or exceed the values
contained in LAMC Table A4.106.5.1(4).
X2
A4.106.6Install a vegetated roof for at least 50% of
the roof area. Vegetated roofs shall comply with
requirements for roof gardens and landscaped roofs
in the_California Building Code_, Chapters 15 and 16.
A4.106.7Reduce nonroof heat islands for 50% of
sidewalks, patios, driveways or other paved areas by
using one or more of the methods listed.
A4.106.8.1Tier 1 and Tier 2 for one- and two-family
dwellings and townhouses with attached private
garages. Install a dedicated 208/240-volt branch
circuit, including an overcurrent protective device
X2 X2
rated at 40 amperes minimum per dwelling unit.
A4.106.8.2Provide capability for future electric
vehicle charging in new multi-family dwellings,
hotels and motels, as specified.
Tier 1. 35 percent of the total number of parking
spaces shall be electric vehicle (EV ready) with low
power Level 2 EV charging receptacles. For projects
with 20 or more dwelling units, sleeping units or
guest rooms, 10 percent of the total number of
parking spaces shall be equipped with Level 2
EVSE.
Tier 2. 40 percent of the total parking spaces shall be
electric vehicle (EV ready) with low power Level 2
EV charging receptacles. For projects with 20 or
more dwelling units, sleeping units or guest rooms,
15 percent of the total number of parking spaces
shall be equipped with Level 2 EVSE.
See LAMC Subdivision 99.04.106.4.2 for additional
requirements related to EVCS for multi-family
dwellings and "R" occupancies other than one- and
X2 X2
two-family dwellings.
A4.106.9Provide bicycle parking facilities as noted
below or meet a local ordinance, whichever is more
stringent. Number of bicycle parking spaces may be
reduced, as approved by the enforcing agency, due
to building site characteristics, including but not
limited to, isolation from other development.
1. Provide short-term bicycle parking, per
CALGreen Section A4.106.9.1.
2. Provide long-term bicycle parking for multi-
family buildings, per CALGreen Section
A4.106.9.2.
3. Provide long-term bicycle parking for hotel and
motel buildings, per CALGreen Section
A4.106.9.3.
**A4.106.10 [HR]**Outdoor lighting systems shall be
designed and installed to comply with:
1. The minimum requirements in the_California_
_Energy Code_for Lighting Zones 1-4; and
2. Backlight, Uplight and Glare (BUG) ratings as
defined in IES TM-15-11; and
3. Allowable BUG ratings not exceeding those
shown in CALGreen Table A4.106.10; or
Comply with a lawfully enacted local ordinance,
whichever is more stringent.
Innovative Concepts and Local Environmental
Conditions
A4.108.1Items in this section are necessary to
address innovative concepts or local environmental
conditions.
Item 1
Item 2
Item 3
ENERGY EFFICIENCY
General
4.201.1Building meets or exceeds the requirements
of the_California Building Energy Efficiency_
X
X2
X2
Standards.3
Performance Approach for Newly Constructed
Buildings
A4.203.1.1Hourly Source Energy Rating
(EDR1). EDR1 ratings for building design shall be
computed by Energy Compliant software and shall
reduce the EDR1 required by the software by the
compliance margins specified in Table A4.203.1.1.
X2
X2
A4.203.1.2Prerequisite options. In addition, a
minimum of two of the efficiency measures
specified in Sections A4.203.1.2.1 through
A4.203.1.2.8 will be required to be met.
• Roof deck insulation or ducts in conditioned
space.
• High-performance walls.
• Compact hot water distribution system.
• Drain water heat recovery.
• High performance vertical fenestration.
• Heat pump water heater demand management.
• Battery storage system controls.
• Heat pump space and water heating.
X2
X2
A4.203.1.3Consultation with local electric service
provider. Local jurisdictions considering adoption of
reduced EDR targets based on using solar
photovoltaic (PV) systems larger than required by
the_California Energy Code_shall consult with the
local electric service provider to ensure that that PV
system sizing required to comply with the EDR
targets will be acceptable to the local electric service
provider.
X2
Performance Approach for Additions
A4.204.1.1Tier 1. If only one mechanical system is
added or modified, the Energy Budget is no greater
than 95% of the Title 24, Part 6, Energy Budget for
the Standard Design Building. If two or more
mechanical systems are added or modified, the
Energy Budget is no greater than 90% of the Title
24, Part 6, Energy Budget for the Standard Design
Building.
X2
A4.204.1.2Tier 2. If only one mechanical system is
added or modified, the Energy Budget is no greater
than 90% of the Title 24, Part 6, Energy Budget for
the Standard Design Building. If two or more
mechanical systems are added or modified, the
Energy Budget is no greater than 85% of the Title
24, Part 6, Energy Budget for the Standard Design
Building.
X2
Renewable Energy
4.211.4Buildings shall comply with the following:
1. All one- and two-family dwellings shall comply
with Section 110.10(b)1A, 110.10(b)2,
110.10(b)3, 110.10(b)4, 110.10(c), 110.10(d) and
110.10(e) of the_California Energy Code_(Title
24, Part 6).
2. All buildings, other than one- and two-family
dwellings, shall comply with Section 110.10(b)
through 110.10(d) of the_California Energy Code_
X

(Title 24, Part 6).
WATER EFFICIENCY AND CONSERVATION
Indoor Water Use
4.303.1Plumbing fixtures (water closets and urinals)
and fittings (faucets and showerheads) installed in
residential buildings shall comply with the
prescriptive requirements of CALGreen Sections
4.303.1.1 through 4.303.1.4.4.
X
4.303.2Plumbing fixtures and fittings required in
CALGreen Section 4.303.1 shall be installed in
accordance with the_California Plumbing Code_, and
shall meet the applicable referenced standards.
X
4.303.3Multi-family dwellings not exceeding three
X
stories and containing 50 units or less shall install a
separate meter or sub-meter within each individual
dwelling unit and within common areas, such as
recreation and laundry rooms.
4.303.4A 20% reduction in the overall use of
potable water within the building shall be provided,
as specified.
X
A4.303.1Kitchen faucets. The maximum flow rate
of kitchen faucets shall not exceed 1.5 gallons per
minute at 60 psi. Kitchen faucets may temporarily
increase the flow above the maximum rate, but not
to exceed 2.2 gallons per minute at 60 psi, and must
default to a maximum flow rate of 1.5 gallons per
minute at 60 psi.
**Note:**Where complying faucets are available,
aerators or other means may be used to achieve
reduction.
A4.303.2Alternate water source for nonpotable
applications. Alternate nonpotable water sources are
used for indoor potable water reduction. Alternate
nonpotable water sources shall be installed in
accordance with the_California Plumbing Code_.
A4.303.3Install at least one qualified ENERGY
STAR dishwasher or clothes washer.
A4.303.4Nonwater urinals or waterless toilets are
installed.
A4.303.5Hot water recirculation systems. One- and
two-family dwellings shall be equipped with a
demand hot water recirculation system, as defined in
Chapter 2 of this Code. The demand hot water
recirculation system shall be installed in accordance
with the_California Plumbing Code_,California
Energy Code, and the manufacturer's installation
instructions.
Outdoor Water Use
4.304.1After December 1, 2015, new residential
developments with an aggregate landscape area
equal to or greater than 500 square feet shall comply
with one of the following options:
1. A local water efficient landscape ordinance or
the current California Department of Water
Resources' Model Water Efficient Landscape
Ordinance (MWELO), whichever is more
stringent; or
2. Projects with aggregate landscape areas less
than 2,500 square feet may comply with the
MWELO's Appendix D Prescriptive Compliance
Option.
X
4.304.3A landscape water meter provided by the
City of Los Angeles Department of Water and Power
shall be installed for landscape irrigation.
X
43044Lk hll b illd ll blil X
**..**ocs sa e nstae on a pucy
accessible exterior faucets and hose bibs.
4.304.5For one- and two-family dwellings, any
permanently installed outdoor in-ground swimming
pool or spa shall be equipped with a cover having a
X

manual or power-operated reel system.
Standards.3
A43041Rainwater catchment sstems An
**..**y.
approved rainwater catchment system is designed
and installed to use rainwater generated by at least
65% of the available roof area. Rainwater catchment
systems shall be designed and installed in
accordance with the_California Plumbing Code_.
A4.304.2Potable water elimination. When
landscaping is provided and as allowed by local
ordinance, a water efficient landscape irrigation
design that eliminates the use of potable water
beyond the initial requirements for plant installation
and establishment should be provided Methods used
.
to accomplish the requirements of this section must
be designed to the requirements of the_California_
_Building Standards Code_and shall include, but not
be limited to, the following:
1. Use of captured rainwater.
2. Use of recycled water.
3. Water treated for irrigation purposes and
conveyed by a water district or public entity.
4. Use of graywater.
A4.304.3For new water service connections,
landscaped irrigated areas less than 5,000 square feet
shall be provided with separate sub-meters or
metering devices for outdoor potable water use.
WATER REUSE SYSTEMS
4.305.1Waste piping shall be arranged to permit the
discharge from the clothes washer, bathtub, showers,
and bathroom/restroom wash basins to be used for a
future graywater irrigation system.
X
4.305.2When City-recycled water is available for
use within 200 feet of the property line, 100% of
water for water closets, urinals, floor drains, and
process cooling and heating in that building shall
come from City-recycled water.
X
4.305.3Cooling towers shall comply with LAMC
Section 99.04.305.3.1 or 99.04.305.3.2.
X
4.305.4Where groundwater is being extracted and
discharged, a system for onsite reuse of the
groundwater shall be developed and constructed.
X
A4.305.1Graywater. Alternative plumbing piping
installed to permit the discharge from the clothes
washer or other fixtures and used for irrigation in
compliance with the Los Angeles Plumbing Code.
A4.305.2Recycled water piping is installed.
A4.305.3Recycled water is used for landscape
irrigation.
Innovative Concepts and Local Environmental
Conditions
A4.306.1Items in this section are necessary to
address innovative concepts or local environmental
conditions.
Item 1
Item 2
Item 3
MATERIAL CONSERVATION AND
RESOURCE EFFICIENCY
Foundation Systems
A4.403.2Cement use in foundation mix design is
reduced.
Tier 1. Not less than a 20% reduction in cement use. X2
Tier 2. Not less than a 25% reduction in cement use. X2
Efficient Framing Techniques
A4.404.1Beams and headers and trimmers are the
minimum size to adequately support the load.
A4.404.2Building dimensions and layouts are
designed to minimize waste.
A4.404.3Use premanufactured building systems to

eliminate solid sawn lumber whenever possible.
A4.404.4Material lists are included in the plans
which specify material quantity and provide
direction for on-site cuts.
Material Sources
A4.405.1One or more of the following building
materials, that do not require additional resources for
finishing are used:
1. Exterior trim not requiring paint or stain.
2 Windows not requiring paint or stain
. .
3. Siding or exterior wall coverings which do not
require paint or stain.

A4.405.2Floors that do not require additional
coverings are used including but not limited to
stained, natural or stamped concrete floors.
A4.405.3Post-consumer or pre-consumer recycled
content value (RCV) materials are used on the
project.
Tier 1. Not less than a 10% recycled content value.
X2
Tier 2. Not less than a 15% recycled content value. X2
A4.405.4Renewable source building products are
used.
Enhanced Durability and Reduced Maintenance
4.406.1Annular spaces around pipes, electric cables,
conduits or other openings in plates at exterior walls
shall be protected against the passage of rodents by
closing such openings with cement mortar, concrete
masonry or similar method acceptable to the
X
enforcing agency.
Water Resistance and Moisture Management
4.407.3Provide flashing details on the building
plans and comply with accepted industry standards
or manufacturer's instructions.
X
4.407.4Protect building materials delivered to the
construction site from rain and other sources of
X
moisture.
A4.407.1Install foundation and landscape drains.
A4.407.2Install gutter and downspout systems to
route water at least 5 feet away from the foundation
or connect to landscape drains which discharge to a
dry well, sump, bioswale, rainwater capture system
or other approved on-site location.
A4.407.6Exterior doors to the dwelling are
protected to prevent water intrusion.
A4.407.7A permanent overhang or awning at least 2
feet in depth is provided.
Construction Waste Reduction, Disposal and
Recycling
4.408.1Comply with Section 66.32 et seq. of the X
Los Angeles Municipal Code.
A4.408.1Construction waste generated at the site is
diverted to recycle or salvage in compliance with
one of the following:

1. Tier 1 at least a 65% reduction. Any mixed
recyclables that are sent to mixed-waste recycling
facilities shall include a qualified third party
verified facility average diversion rate.
Verification of diversion rates shall meet
minimum certification eligibility guidelines,
acceptable to the local enforcing agency.
2. Tier 2 at least a 75% reduction with a third-
party verification.
X2 X2
**Exception:**Equivalent waste reduction methods
are developed by working with local agencies.

Building Maintenance and Operation
4.410.1An operation and maintenance manual shall X
be provided to the building occupant or owner.
4.410.2Where 5 or more multi-family dwelling
units are constructed on a building site, provide
readily accessible areas that serve all buildings on
the site and is identified for the depositing, storage
and collection of non-hazardous materials for
recycling, including (at a minimum) paper,
corrugated cardboard, glass, plastics, organic waste,
and metals or meet a lawfully enacted local
X
recycling ordinance, if more restrictive. See
exception for rural jurisdictions.
Innovative Concepts and Local Environmental
Conditions
A4.411.1Items in this section are necessary to
address innovative concepts or local environmental
conditions.
Item 1
Item 2
Item 3
ENVIRONMENTAL QUALITY
Fireplaces
4.503.1Any installed gas fireplace shall be a direct-
vent sealed-combustion type. Any installed
woodstove or pellet stove shall comply with U.S.
EPA New Source Performance Standards (NSPS)
emission limits as applicable, and shall have a
permanent label indicating they are certified to meet
the emission limits. Woodstoves, pellet stoves and
fireplaces shall also comply with applicable local
ordinances.
X
Pollutant Control
4.504.1Duct openings and other related air
distribution component openings shall be covered
during construction.
X
4.504.2.1Adhesives, sealants and caulks shall be
compliant with VOC and other toxic compound
limits
X
4.504.2.2Paints, stains and other coatings shall be
compliant with VOC limits.
X
4.504.2.3Aerosol paints and coatings shall be
compliant with product weighted MIR limits for
ROC and other toxic compounds.
X
4.504.2.4Documentation shall be provided to verify
that compliant VOC limit finish materials have been
used.
X
4.504.3Carpet and carpet systems shall be
compliant with VOC limits.
X
4.504.480% of floor area receiving resilient flooring
shall comply with specified VOC criteria.
4.504.5Particleboard, medium density fiberboard
(MDF) and hardwood plywood used in interior
finish systems shall comply with low formaldehyde
X
emission standards.
A4.504.1Use composite wood products made with
either California Air Resources Board approved no-
added formaldehyde (NAF) resins or ultra-low
emitting formaldehyde (ULEF) resins.
A4.504.2Install VOC compliant resilient flooring
systems.
Tier 1. At least 90% of the resilient flooring installed
shall comply.
Tier 2. At least 100% of the resilient flooring
installed shall comply.
X2 X2
A4.504.3Thermal insulation installed in the
building shall meet the following requirements:
Tier 1. Install thermal insulation in compliance with
VOC limits..
Tier 2. Install insulation which contains No-Added
X2 X2
Formaldehyde (NAF) and is in compliance with Tier
1.
Interior Moisture Control
4.505.2Vapor retarder and capillary break is X
1. Exterior trim not requiring paint or stain.
2 Windows not requiring paint or stain

installed at slab-on-grade foundations.
4.505.3Moisture content of building materials used
in wall and floor framing is checked before
enclosure.
X
Indoor Air Quality and Exhaust
4.506.1Return air filters with a value greater than
MERV 6 shall be installed on HVAC systems.
Pressure drop across the filter shall not exceed 0.1
inches water column.
**A4.506.2 [HR]**Provide filters on return air openings
rated MERV 6 or higher during construction when it
is necessary to use HVAC equipment.
A4.506.3Direct-vent appliances shall be used when
equipment is located in conditioned space; or the
equipment must be installed in an isolated
mechanical room.
Environmental Comfort
**4.507.2.**Duct systems are sized, designed, and
equipment is selected using the following methods:
1. Establish heat loss and heat gain values
according to ANSI/ACCA 2 Manual J-2011 or
equivalent.
2. Size duct systems according to ANSI/ACCA 1
Manual D-2014 or equivalent.
3. Select heating and cooling equipment according
to ANSI/ACCA 3 Manual S-2014 or equivalent.
X
Outdoor Air QualityReserved
Innovative Concepts and Local Environmental
Conditions
A4.509.1Items in this section are necessary to
address innovative concepts or local environmental
conditions.
Item 1
Item 2
Item 3
Installer and Special Inspector Qualifications
Qualifications
702.1HVAC system installers are trained and
certified in the proper installation of HVAC systems.
X
702.2Special inspectors employed by the enforcing
agency must be qualified and able to demonstrate
competence in the discipline they are inspecting.
X
Verifications
703.1Verification of compliance with this code may
include construction documents, plans,
specifications, builder or installer certification,
inspection reports, or other methods acceptable to
the enforcing agency which show substantial
conformance.
X
  1. Green building measures listed in this table may be mandatory if adopted by a city, county, or city and county as specified in CALGreen Section 101.7.

  2. Required prerequisite for this Tier.

  3. These measures are currently required elsewhere in statute or in regulation.

DIVISION 12

APPENDIX A5 NONRESIDENTIAL VOLUNTARY MEASURES

(Amended by Ord. No. 182,849, Eff. 1/3/14.)