SEC. 99.08.100. BASIC PROVISION.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Chapter 8 of the California Green Building Code is not adopted, and, in lieu, Division 8, Article 9, Chapter IX of the Los Angeles Municipal Code is added as provided in this article.

WORKSHEET (WS-1)

BASELINE WATER USE (Amended by Ord. No. 186,488, Eff. 12/27/19.)

BASE
LIN E WATER USE
CALC ULATION T
ABL E
FIXTURE TYPE FLOW RATE DURATION DAILY OCCUPANTS GALLONS
USES PER DAY
BASE
LIN E WATER USE
CALC ULATION T
ABL E
FIXTURE TYPE FLOW RATE DURATION DAILY
USES
OCCUPANTS GALLONS
PER DAY
Showerheads,
residential
1.8 gpm @
80 psi
x 8 min. x 1 x Note 1a =
Showerheads,
nonresidential
1.8 gpm @
80 psi
x 5 min. x 1 x =
Lavatory faucets,
residential
1.2 gpm @
60 psi
x 0.25 min. x 3 x =
Lavatory faucets
nonresidential/public
uses
0.5 gpm @
60 psi
x 0.25 min x 3 x =
Kitchen faucets 1.8 gpm @
60 psi
x 4 min. x 1 x Note 1b =
Wash fountains 1.8 gpm/20
[rim space (in)
@ 60 psi]
x x x =
Metering faucets 0.25
gallons/cycle
x 0.25 min. x 3 x =
Metering faucets for
wash fountains
0.20
gal/cycle/20
[rim space (in.)
@ 60 psi]
x 0.25 min. x x =
Water Closets 1.28
gallons/flush
x 1 flush x 1 male2
3 females
x =
Urinals 0.125
gallons/flush
x 1 flush x 2 males x =
Total dai ly ba seline water use ( BW U) =
  1. Refer to Table A, Chapter 4 of the California Plumbing Code, for occupant load factors.
  • a. Shower use by occupants depends on the type of use of a building or portion of a building, e.g. total occupant load for a health club, but only a fraction of the occupants in an office building as determined by the anticipated number of users.

  • b. Kitchen faucet use is determined by occupant load of the area served by the fixture.

  1. The daily use number shall be increased to three if urinals are not installed in the room.

WORKSHEET (WS-2)

BASELINE WATER USE

20-PERCENT
RED UCTION WATE
R US E CALCUL
ATIO N TABLE
FIXTURE TYPE
FLOW RATE
20-PERCENT
RED DURATION
UCTION WATE
R US DAILY
USES
E CALCUL
ATIO OCCUPANTS
N TABLE
GALLONS
PER DAY
FIXTURE TYPE FLOW RATE DURATION DAILY
USES
OCCUPANTS GALLONS
PER DAY
Showerheads,
residential
x 8 min. x 1 x Note 1a =
Showerheads,
nonresidential
x 5 min. x 1
Lavatory faucets,
residential
x 0.25 min. x 3 x =
Lavatory faucets x 0.25 min x 3 x =
nonresidential/public
uses
Kitchen faucets x 4 min. x 1 x Note 1b =
Wash fountains x x x =
Metering faucets x 0.25 min. x 3 =
Metering faucets for
wash fountains
x 0.25 min. x x =
Water Closets x 1 flush x 1 male2
3 females
x =
Urinals x 1 flush x 2 males x =
Urinals
Nonwater supplied
0.0 gal/ flush x 1 flush x 2 males x = 0
Pro posed water use (BW U) =
20% Redu ction __________ ____( BWU from WS -1) x 0 .80 = ______ _____ __ Allowable w ater use
____% Redu ction __________ ____( BWU from W S-1) x 0.____ = ___ ______ ___ Allowable water use
  1. For occupancies, refer to Table A, Chapter 4, California Plumbing Code, for occupant load factors.
  • a. Shower use by occupants depends on the type of use of a building or portion of a building, e.g., total occupant load for a health club, but only a fraction of the occupants in an office building as determined by the anticipated number of users.

  • b. Kitchen faucet use is determined by the occupant load of the area served by the fixture.

  1. Includes single and dual flush water closets with an effective flush of 1.28 gallons or less.
  • Single flush toilets - The effective flush volume shall not exceed 1.28 gallons (4.8 liters). The effective flush volume is the average flush volume when tested in accordance with ASME A112.19.2.

Dual flush toilets - The effective flush volume shall not exceed 1.28 gallons (4.8 liters). The effective flush volume is defined as the composite, average flush volume of two reduced flushes and one full flush. Flush volumes will be tested in accordance with ASME A112.19.2 and ASME A112.19.14.

  1. The daily use number shall be increased to three if urinals are not installed in the room.

  2. Where complying faucets are unavailable, aerators rated at 35 gpm or other means may be used to achieve reduction.

DIVISION 11

APPENDIX A4 RESIDENTIAL VOLUNTARY MEASURES

(Amended by Ord. No. 182,849, Eff. 1/3/14.)

Section

99.11.101 Scope. 99.11.102 General. 99.11.602