SEC. 92.0302. PRIVATE RESIDENCE INCLINED ELEVATORS.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
(Amended by Ord. No. 185,587, Eff. 7/16/18.)
All inclined elevators in private residences shall comply with the provisions of ASME A 17.1 and this article. Part 5, Section 5.4 of ASME A 17.1-2004 is adopted by reference, with the following exceptions and modifications: ASME Sections 5.3.1.7.7, 5.3.1.18.4, 5.3.1.18.5 and 5.4.8 are not adopted.
(a) Suspension Means. Suspension means shall comply with Part 5, Section 5.3.1.12 of ASME A 17.1-2004.
(b) Machine and Controls. Machine and controls shall be located as follows:
Machines, controls and disconcerting means shall not be mounted on cars, and shall be located outside of the hoistway in spaces dedicated to the elevator equipment.
The machine room shall have a head clearance of at least seven feet, and shall be provided with permanent electric lighting and a duplex receptacle rated at not less than 15A at 120V.
Required workspace clearance for elevator control and/or machinery spaces shall be located entirely within the interior of the building.
(c) Maintenance. The owner shall develop, implement, and maintain a written maintenance program for Private Residence Inclined Elevators in accordance with the manufacturer's recommendations. The maintenance shall be performed by a registered Journey-Level Elevator Mechanic as required by LAMC Section 92.0119. A log of all repairs and maintenance shall be kept at the location.
SEC. 92.0303. PRIVATE RESIDENCE VERTICAL PLATFORM LIFTS.
(Title and Section Amended by Ord. No. 182,846, Eff. 1/3/14.)
Part 5 of ASME A18.1-2003 is adopted by reference, with the following exceptions: Rule 5.1.4.1 and Rule 5.10.9.1 are not adopted.
92.0303.1. Private Residence Inclined Platform Lifts. Part 6 of ASME A18.1-2003 is adopted by reference, with the following exceptions: Rule 6.1.6.1 and Rule 6.10.6.1 are not adopted.
92.0303.2. Private Residence Inclined Stairway Chairlifts. Part 7 of ASME A18.1-2003 is adopted by reference, with the following exceptions: Rule 7.1.3 and Rule 7.10.3.1 are not adopted.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
- Division 67
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
- Division 94
- Division 95
▸Division 96
Overview- SEC. 91.9602. SCOPE.
- SEC. 91.9603. DEFINITIONS.
- SEC. 91.9604. ANALYSIS AND DESIGN.
- SEC. 91.9605. MATERIALS OF CONSTRUCTION.
- SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9701. TITLE.
- SEC. 91.9702. PURPOSE.
- SEC. 91.9703. SCOPE.
- SEC. 91.9704. DEFINITIONS.
- SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
- SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
- SEC. 91.9707. RECORD MAINTENANCE.
- SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
- SEC. 91.9709. NONCOMPLIANCE FEE.
- SEC. 91.9710. SUBMITTAL FEES.
- SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
- SEC. 91.9712. SEVERABILITY.
- Article 1.2
- Article 1.5
- Article 1.5 — , DIVISION 1
- Article 1.5 — , DIVISION 2
- Article 1.5 — , DIVISION 3
- Article 1.5 — , DIVISION 4
- Article 1.5 — , DIVISION 5
- Article 1.5 — , DIVISION 6
- Article 1.5 — , DIVISION 7
- Article 1.5 — , DIVISION 8
- Article 1.5 — , DIVISION 9
- Article 2
- Part 2
▸Part 3
Overview- SEC. 92.0135. POWERS OF DEPARTMENT AND BOARD.
- SEC. 92.0136. APPEALS.
- SEC. 92.0137. EXPIRATION OF PERMIT AND PLAN CHECK.
- SEC. 92.0138. SCOPE OF PERMITS.
- SEC. 92.0139. NON-RESPONSIBILITY OF CITY.
- SEC. 92.0140. PROCEDURE FOR REVOCATION OR SUSPENSION.
- SEC. 92.0141. ALTERNATE MATERIALS AND METHODS OF CONSTRUCTION.
- SEC. 92.0201. RESERVED.
- SEC. 92.0202. GENERAL.
- SEC. 92.0204. RESERVED.
- SEC. 92.0205. RETROACTIVE PROVISIONS.
- SEC. 92.0206. MECHANICAL LOCKS AND ELECTRIC CONTACTS.
- SEC. 92.0207. ADDITIONAL REQUIREMENTS.
- SEC. 92.0302. PRIVATE RESIDENCE INCLINED ELEVATORS.
- SEC. 92.0304. PRIVATE RESIDENCE ELEVATORS.
- SEC. 92.0312. NAMEPLATE.
- SEC. 92.0313. MAINTENANCE.
- SEC. 92.0401. SCOPE.
- SEC. 92.0402. GENERAL.
- Article 3
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D