SEC. 92.0402. GENERAL.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
(Amended by Ord. No. 158,169, Eff 8/3/83.)
(a) Definition. A device consisting of a power driven endless belt provided with steps or platforms and handholds attached to it for the vertical transportation of personnel.
(b) Installation and Limitation of Use. The installation of new manlifts is hereby prohibited, and any presently existing manlifts shall be removed from use not later than May 23, 1984 unless expressly excepted in this section.
EXCEPTIONS: The installation of manlifts in flour mills is not prohibited. The requirement of removal from use not later than May 23, 1984 is not applicable to flour mills, borax silos, parking structures, or electric generating stations, provided that any manlift in such facility is completely enclosed by a fence, and access gates thereto are locked so as to prevent unauthorized and untrained personnel from using the device, and provided further that the City has authority to enter the premises in order to insure that the fence and locked gates are provided and properly maintained. (Amended by Ord. No. 182,846, Eff. 1/3/14.)
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
- Division 67
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
- Division 94
- Division 95
▸Division 96
Overview- SEC. 91.9602. SCOPE.
- SEC. 91.9603. DEFINITIONS.
- SEC. 91.9604. ANALYSIS AND DESIGN.
- SEC. 91.9605. MATERIALS OF CONSTRUCTION.
- SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9701. TITLE.
- SEC. 91.9702. PURPOSE.
- SEC. 91.9703. SCOPE.
- SEC. 91.9704. DEFINITIONS.
- SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
- SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
- SEC. 91.9707. RECORD MAINTENANCE.
- SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
- SEC. 91.9709. NONCOMPLIANCE FEE.
- SEC. 91.9710. SUBMITTAL FEES.
- SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
- SEC. 91.9712. SEVERABILITY.
- Article 1.2
- Article 1.5
- Article 1.5 — , DIVISION 1
- Article 1.5 — , DIVISION 2
- Article 1.5 — , DIVISION 3
- Article 1.5 — , DIVISION 4
- Article 1.5 — , DIVISION 5
- Article 1.5 — , DIVISION 6
- Article 1.5 — , DIVISION 7
- Article 1.5 — , DIVISION 8
- Article 1.5 — , DIVISION 9
- Article 2
- Part 2
▸Part 3
Overview- SEC. 92.0135. POWERS OF DEPARTMENT AND BOARD.
- SEC. 92.0136. APPEALS.
- SEC. 92.0137. EXPIRATION OF PERMIT AND PLAN CHECK.
- SEC. 92.0138. SCOPE OF PERMITS.
- SEC. 92.0139. NON-RESPONSIBILITY OF CITY.
- SEC. 92.0140. PROCEDURE FOR REVOCATION OR SUSPENSION.
- SEC. 92.0141. ALTERNATE MATERIALS AND METHODS OF CONSTRUCTION.
- SEC. 92.0201. RESERVED.
- SEC. 92.0202. GENERAL.
- SEC. 92.0204. RESERVED.
- SEC. 92.0205. RETROACTIVE PROVISIONS.
- SEC. 92.0206. MECHANICAL LOCKS AND ELECTRIC CONTACTS.
- SEC. 92.0207. ADDITIONAL REQUIREMENTS.
- SEC. 92.0302. PRIVATE RESIDENCE INCLINED ELEVATORS.
- SEC. 92.0304. PRIVATE RESIDENCE ELEVATORS.
- SEC. 92.0312. NAMEPLATE.
- SEC. 92.0313. MAINTENANCE.
- SEC. 92.0401. SCOPE.
- SEC. 92.0402. GENERAL.
- Article 3
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D