Section 91.5.900 Basic Provisions.

SEC. 91.5.900. BASIC PROVISIONS.

(Amended by Ord. No. 186,488, Eff. 12/27/19.)

Chapter 9 of the CRC is hereby adopted by reference except as amended or modified herein. Section R902.2 of the 2019 California Residential Code is not adopted.

91.5.902.2. Fire-retardant-treated Shingles and Shakes. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 for use on Class A, B or C roofs. Fire-retardant-treated wood shakes and shingles shall comply with ICC-ES EG107 and with the weathering requirements contained in California Health and Safety Code Section 13132.7(j). Each bundle shall bear labels from an ICBO accredited quality control agency identifying their roof-covering classification and indicating their compliance with ICC-ES EG107 and with the weathering requirements contained in California Health and Safety Code Section 13132.7(j).

No wood shake or shingle roof covering is permitted as provided by LAMC Subsection 91.1505.1.

ARTICLE 1.5, DIVISION 10

[CHIMNEYS AND FIREPLACES]

Section 91.5.1000 Basic Provisions.

SEC. 91.5.1000. BASIC PROVISIONS.

Chapter 10 of the CRC is hereby adopted by reference with the following exceptions, modifications and additions.

91.5.1001.3.1. Vertical Reinforcing. (Amended by Ord. No. 186,488, Eff. 12/27/19.) For chimneys up to 40 inches (1016 mm) wide, four No. 4 continuous vertical bars adequately anchored into the concrete foundation shall be placed between wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance with CRC Section R606. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches (1016 mm) in width or fraction thereof.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Los Angeles Building Code — LAMC Chapter IX
Los Angeles Building Code — LAMC Chapter IX
  1. Chapter IX
  2. Chapter IX — BUILDING REGULATIONS
  3. Division 1
  4. Division 2
  5. Division 3
  6. Division 4
  7. Division 5
  8. Division 6
  9. Division 7
  10. Division 8
  11. Division 9
  12. Division 10
  13. Division 11
  14. Division 12
  15. Division 13
  16. Division 14
  17. Division 15
  18. Division 16
  19. Division 17
  20. Division 18
  21. Division 19
  22. Division 20
  23. Division 21
  24. Division 22
  25. Division 23
  26. Division 24
  27. Division 25
  28. Division 26
  29. Division 27
  30. Division 28
  31. Division 29
  32. Division 30
  33. Division 31
  34. Division 32
  35. Division 33
  36. Division 34
  37. Division 35
  38. Division 61
  39. Division 62
  40. Division 63
  41. Division 67
  42. Division 70
  43. Division 71
  44. Division 72
  45. Division 82
  46. Division 83
  47. Division 85
  48. Division 88
  49. Division 89
  50. Division 90
  51. Division 91
  52. Division 92
  53. Division 93
  54. Division 94
  55. Division 95
  56. Division 96
  57. Division 5 — REGISTRATION
  58. Division 16A
  59. Division 17
  60. Division 18
  61. Division 19
  62. Division 20
  63. Division 21
  64. Division 17
  65. Division 18
  66. Division C
  67. Division D

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.