SEC. 91.9409. INFORMATION REQUIRED ON PLANS.
Los Angeles Building Code — LAMC Chapter IX · 2026-08 edition · updated 2026-09-09 · Los Angeles
(Added by Ord. No. 171,258, Eff. 8/30/96.)
91.9409.1. General. The licensed engineer or architect responsible for the seismic analysis of the building shall record the information required by this section on the approved plans. The plans shall accurately reflect the results of the engineering investigation and design and show all pertinent dimensions and sizes for plan review and construction. The plans shall show existing framing construction, diaphragm construction, proposed primary, alternate and secondary anchors, proposed shear
walls and collectors for the base and below. All structural elements that are part of the design including existing nailing, anchors, ties, and collectors, shall be shown on the plans. The plans shall indicate existing construction that has not been exposed and needs verification at the time of construction.
91.9409.2. Building Elevations. Elevations showing the existing conditions shall be drawn to scale. Elevations shall show roof and floor heights, dimensions of openings, location and extent of existing damage, and proposed repair and strengthening.
91.9409.3. Shear Walls. Plans shall include all information pertinent to shear walls, including typical wall panel thickness, length, and the location and size of all anchors.
91.9409.4. Details. Details shall include the existing lateral bracing systems to be utilized including work required for the lateral and vertical load systems and new anchors and the method of development of anchor forces into the diaphragm framing.
91.9409.5. Engineer’s or Architect’s Statement. (Amended by Ord. No. 185,587, Eff. 7/16/18.) The responsible engineer or architect shall state on the approved plans the following:
- "I am responsible for designing the strengthening for this building's base level and below in compliance with the minimum regulations of Division 94, Article 1, Chapter IX of the LAMC; and either I or someone under my responsible charge has performed the pre-design investigation."
or when applicable:
- "The Registered Deputy Inspector, required as a condition of the use of structural design stresses requiring continuous inspection, will be responsible to me as required by LAMC Section 91.1704."
TABLE 94-A VALUES FOR EXISTING MATERIALS
| Existing Materials or Configuration of Materials1 | Allowable Values |
|---|---|
| 1. Plain or reinforced concrete footings | f'c= 2000 psi (13.8 MPa) unless otherwise shown by tests. |
| 2. Douglas fir wood | Allowable stress same as No. 2 D.F. |
| 3. Reinforcing steel | fs= 0.4_Fy_, maximum 16 ksi (110 MPa). |
| 4. Structural steel | _fb =0.6_Fy, maximum 22 ksi (152 MPa). |
| 5. Anchor bolts | Current code values. |
| 6. Wood structural panels/diagonal sheathing | Current code values. |
1 Material must be sound and in good condition.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — Los Angeles Building Code — LAMC Chapter IX
- Chapter IX
- Chapter IX — BUILDING REGULATIONS
- Division 1
- Division 2
- Division 3
- Division 4
- Division 5
- Division 6
- Division 7
- Division 8
- Division 9
- Division 10
- Division 11
- Division 12
- Division 13
- Division 14
- Division 15
- Division 16
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 22
- Division 23
- Division 24
- Division 25
- Division 26
- Division 27
- Division 28
- Division 29
- Division 30
- Division 31
- Division 32
- Division 33
- Division 34
- Division 35
- Division 61
- Division 62
- Division 63
- Division 67
- Division 70
- Division 71
- Division 72
- Division 82
- Division 83
- Division 85
- Division 88
- Division 89
- Division 90
- Division 91
- Division 92
- Division 93
▸Division 94
- Division 95
- Division 96
- Division 5 — REGISTRATION
- Division 16A
- Division 17
- Division 18
- Division 19
- Division 20
- Division 21
- Division 17
- Division 18
- Division C
- Division D