Section R906
California Residential Code (Title 24, Part 2.5) · 2022 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
R906.1 General.¶
Where above-deck thermal insulation is installed, such insulation shall be covered with an approved roof covering and shall comply with NFPA 276 or UL 1256.
R906.2 Material standards.¶
Above-deck thermal insulation board shall comply with the standards in Table R906.2.
TABLE R905.16.6 CLASSIFICATION OF PHOTOVOLTAIC SHINGLES
| MAXIMUM ULTIMATE DESIGN WIND SPEED, V, FROM FIGURE R301.2(2) (mph) ult |
MAXIMUM BASIC WIND SPEED, V, FROM TABLE R301.2.1.3 (mph) ASD |
UL 7103 SHINGLE CLASSIFICATION |
|---|---|---|
| 110 | 85 | A, D or F |
| 116 | 90 | A, D or F |
| 129 | 100 | A, D or F |
| 142 | 110 | F |
| 155 | 120 | F |
| 168 | 130 | F |
| 181 | 140 | F |
| 194 | 150 | F |
For SI: 1 mile per hour = 1.609 kph.
9-16 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
| TABLE MATERIAL STANDARDS | R906.2 FOR ROOF INSULATION |
|---|---|
| Cellular glass board | ASTM C552 |
| Composite boards | ASTM C1289, Type III, IV, V or VI |
| Expanded polystyrene | ASTM C578 |
| Extruded polystyrene board | ASTM C578 |
| Fiber-reinforced gypsum board | ASTM C1278 |
| Glass-faced gypsum board | ASTM C1177 |
| Mineral wool board | ASTM C726 |
| Perlite board | ASTM C728 |
| Polyisocyanurate board | ASTM C1289, Type I or II |
| Wood fiberboard | ASTM C208 |
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Residential Code (Title 24, Part 2.5)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix AF — RADON CONTROL
- Appendix AI — PRIVATE SEWAGE
- Appendix AJ — EXISTING
- Appendix AK — SOUND
- Appendix AO — AUTOMATIC
- Appendix AR — LIGHT STRAW-CLAY
- Appendix AS — STRAWBALE
- Appendix AU — COB CONSTRUCTION
- Appendix AV — BOARD
- Appendix AW — 3D-PRINTED BUILDING
- Chapter 1 — SCOPE AND APPLICATION
- Chapter 3 — BUILDING PLANNING
- Chapter 4 — FOUNDATIONS
- Chapter 5 — FLOORS
- Chapter 6 — WALL CONSTRUCTION
- Chapter 7 — WALL COVERING
- Chapter 8 — ROOF-CEILING CONSTRUCTION
▸Chapter 9 — ROOF ASSEMBLIES
- Chapter 10 — CHIMNEYS AND FIREPLACES
- Chapter 44 — REFERENCED STANDARDS
- Appendix AH — PATIO COVERS
- Appendix AL — PERMIT FEES
- Appendix AQ — TINY HOUSES
- Appendix AT — SOLAR-READY PROVISIONS—DETACHED ONE- AND
- Appendix AX — SWIMMING POOL SAFETY ACT
- Appendix AY — AREAS PROTECTED BY THE FACILITIES
- Appendix AZ — EMERGENCY HOUSING