Appendix AZ — EMERGENCY HOUSING
Section AZ110
California Residential Code (Title 24, Part 2.5) · 2022 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
AZ110.1 Drinking water.¶
Potable drinking water shall be provided for all occupants of emergency housing.
AZ110.2 Kitchens.¶
Where occupants of dependent units are permitted or required to cook for themselves, a separate area shall be equipped and maintained as a common use kitchen. Refrigerated storage shall be provided for safe storage of food.
AZ110.3 Toilet and bathing facilities.¶
When dependent units are used as emergency housing, the emergency housing site shall be provided with one toilet and one bathing facility for every 15 occupants of each gender. The enforcing agency may permit different types and ratios of toilet and bathing facilities. The approval shall be based upon a finding that the type and ratio of toilet and bathing facilities are sufficient to process the anticipated volume of sewage and waste water, while maintaining sanitary conditions for the occupants of the emergency housing.
Bathing facilities shall be provided with heating equip- ment which shall be capable of maintaining a temperature of 70 degrees F (21.0 degrees Celsius) within such facilities.
APPENDIX AZ-4 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
APPENDIX AZ—EMERGENCY HOUSING
Lavatories with running water shall be installed and maintained in the toilet facilities or adjacent to the toilet facilities.
AZ110.4 Garbage, waste and rubbish disposal.¶
All garbage, kitchen waste and rubbish shall be deposited in approved covered receptacles, which shall be emptied when filled and the contents shall be disposed of in a sanitary manner accept- able to the enforcing agency.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
APPENDIX AZ-6 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
ALTERNATE MATERIALS
(see MATERIALS) . . . . . . . . . . . . . . . . . . . .R104.11 ANCHOR BOLTS . . . . . . . . . . . . . . . . . . . . . R403.1.6 APPEAL
Board of . . . . . . . . . . . . . . . . . . . . . . . . 1.8.8, R112.1 Right of . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8.8, R112 APPLIANCE
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 APPLICATION
Plywood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.3 APPROVED
Agent (definition). . . . . . . . . . . . . . . . . . . . . . . . R202 Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Source (definition). . . . . . . . . . . . . . . . . . . . . . . R202 AREA
Flue (appliances) . . . . . . . . . . . . . . . . . . . . R1003.14 Flue masonry . . . . . . . . . . . . . . . . . . . . . . . R1003.15 Room, minimum . . . . . . . . . . . . . . . . . . . . . . . . R304 AREA WELLS . . . . . . . . . . . . . . . . . . . . . . . . . . R310.4 ASPHALT SHINGLES . . . . . . . . . . . . . . . . . . . . R905.2 ATTIC
Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R807 Habitable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R326 AUTOMATIC FIRE SPRINKLER SYSTEMS . . . R313
B
BACKFLOW, DRAINAGE
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BACKWATER VALVE
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BASEMENT WALL
Definition. . . . . . . . . . . . . . . . . . . . . . .R202, N1101.6 BATH, TOILET AND SHOWER SPACES . . . . . . R307 BATHROOM
Exhaust fan. . . . . . . . . . . . . . . . . . . . . . . . . R303.3.1 Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BATHTUB
Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R307.2 Space required . . . . . . . . . . . . . . . . . . . . . . . . R307.1 BEAM SUPPORTS . . . . . . . . . . . . . . . . . . . . . R606.14 BEARING
Of joists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R502.6 BOILER
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILDING
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Drain, definition. . . . . . . . . . . . . . . . . . . . . . . . . R202 Existing, definition. . . . . . . . . . . . . . . . . . . . . . . R202
| � | A | |
|---|---|---|
| ° ° |
° ° |
ACCESS (TO) |
| ° | ° | Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 To attic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R807 |
| ° | ° | To crawl space . . . . . . . . . . . . . . . . . . . . . . . . R408.4 ACCESSIBILITY . . . . . . . . . . . . . . . . . . . . . . . . . .R320 |
| ACCESSORY DWELLING UNIT. . . . . . . . . . . . . .R202 | ||
| ° | ° | AUTHORITY TO ENFORCE AUTOMATIC FIRE SPRINKLER SYSTEMS. . . . . . . . . . 1.8.9.1, R313.2 ACCESSORY STRUCTURE |
| ° | ° | Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 ADDRESS (SITE) . . . . . . . . . . . . . . . . . . . . . . . . .R319 |
| ADMINISTRATION, CALIFORNIA Chapter 1, Division 1 |
||
| General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 | ||
| Dept. of Housing and Community Development. . 1.8 | ||
| Office of the State Fire Marshal . . . . . . . . . . . . . 1.11 | ||
| ADMINISTRATION, DIVISION II. . . . . . . . . . Chapter 1 | ||
| Applicability. . . . . . . . . . . . . . . . . . . . . . . . . . . . .R102 | ||
| Authority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R104 | ||
| Board of appeals . . . . . . . . . . . . . . . . . . . . . . . .R112 | ||
| Certificate of occupancy . . . . . . . . . . . . . . . . . . .R110 | ||
| Construction documents. . . . . . . . . . . . . . . . . . .R106 | ||
| Department of building safety. . . . . . . . . . . . . . .R103 | ||
| Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R104.6 | ||
| Fees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R106 | ||
| General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R101 | ||
| Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R109 | ||
| Permits . . . . . . . . . . . . . . . . . . . . . . . R105,R105.5.1 | ||
| Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R101.3 | ||
| Service utilities . . . . . . . . . . . . . . . . . . . . . . . . . .R111 | ||
| Stop work order . . . . . . . . . . . . . . . . . . . . . . . . .R114 | ||
| Temporary structures and uses . . . . . . . . . . . . .R107 | ||
| Violations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R113 | ||
| AGING-IN-PLACE DESIGN AND FALL PREVENTION_ . . . . . . . . . . . . . . . . R327_ |
||
| Doorbell buttons . . . . . . . . . . . . . . . . . . . . . .R327.1.4 | ||
| Electrical receptacle outlet, switch and control heights . . . . . . . . . . . . . . . . . .R327.1.2 |
||
| Interior doors . . . . . . . . . . . . . . . . . . . . . . . .R327.1.3 | ||
| Reinforcement for grab bars. . . . . . . . . . . . .R327.1.1 | ||
| AIR | ||
| ° | ° | Combustion . . . . . . . . . . . . . . . . . . . . . . . Chapter 17 |
| ° | ° | Combustion air, definition . . . . . . . . . . . . . . . . . .R202 ALLOWABLE SPANS |
| Of floor joists. . . . . . . . . . . . . . . . . .R502.3, R505.3.2 | ||
| Of headers . . . . . . . . . . . . . . . . . . . . R602.7, R603.6 | ||
| Of rafters and ceiling joists . . . . . . . .R802.4, R802.5, R804.3.1, R804.3.2 |
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
| Sewer, definition . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILDING OFFICIAL |
CARPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . R309.2 CEILING |
° | ||||
|---|---|---|---|---|---|---|
| ° | ° | Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILDING PLANNING Accessibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . R320 |
Finishes . . . . . . . . . . . . . . . . . . . . . . . . R302.9, R805 Height. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R305 CERTIFICATE OF OCCUPANCY . . . . . . . . . . . . R110 |
° | ° | |
| Automatic fire sprinkler systems . . . . . . . . . . . . R313 | CHANGE OF OCCUPANCY | |||||
| Carbon monoxide alarms. . . . . . . . . . . . . . . . . . R315 | Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | |||||
| Ceiling height . . . . . . . . . . . . . . . . . . . . . . . . . . . R305 | CHASES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R606.8 | ° | ° | |||
| Design criteria . . . . . . . . . . . . . . . . . . . . . . . . . . R301 | CHIMNEYS | |||||
| Elevators and platform lifts . . . . . . . . . . . . . . . . R321 | And fireplaces . . . . . . . . . . . . . . . . . . . . . Chapter 10 | |||||
| Emergency escape . . . . . . . . . . . . . . . . . . . . . . R310 | Caps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.9.1 | |||||
| Energy Storage Systems . . . . . . . . . . . . . . . . . . R328 | Clearance. . . . . . . . . . . . . . . . . . . . . . . . . . R1003.18 | |||||
| Exterior wall . . . . . . . . . . . . . . . . . . . . . . . . . . R302.1 | Corbeling . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.5 | |||||
| Fire-resistant construction . . . . . . . . . . . . . . . . . R302 | Crickets . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.20 | |||||
| Flood-resistant construction. . . . . . . . . . . . . . . . R322 | Design (masonry). . . . . . . . . . . . . . . . . . . . . R1003.1 | |||||
| Foam plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . R316 | Factory-built . . . . . . . . . . . . . . . . . . . . . . . . . . . R1005 | |||||
| Garages and carports . . . . . . . . . . . . . . . . . . . . R309 | Fireblocking . . . . . . . . . . . . . . . . . . . . . . . . R1003.19 | |||||
| Glazing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R308 | Flue area . . . . . . . . . . . . . . . . . .R1003.14, R1003.15 | |||||
| Guardrails_or Guards_ . . . . . . . . . . . . . . . . . . . . . R312 | Flue lining. . . . . . . . . . . . . . . . . . . . . . . . . . R1003.11 | |||||
| Handrails . . . . . . . . . . . . . . . . . . .R311.7.8, R311.8.3 Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . R302.10 |
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.8 Multiple flues_ . . . . . . . . . . . . . . . . . . . . . . . R1003.13_ |
° | ° | |||
| Landing . . . . . . . . . . . . . R311.3, R311.3.1, R311.3.2 | Rain caps . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.9.3 | |||||
| Light, ventilation and heating . . . . . . . . . . . . . . . R303 | Spark arrestors. . . . . . . . . . . . . . . . . . . . . . R1003.9.2 | |||||
| Means of egress . . . . . . . . . . . . . . . . . . . . . . . . R311 | Termination . . . . . . . . . . . . . . . . . . . . . . . . . R1003.9 | |||||
| Mezzanines . . . . . . . . . . . . . . . . . . . . . . . . . . . . R325 | Wall thickness . . . . . . . . . . . . . . . . . . . . . . R1003.10 | |||||
| Minimum room area. . . . . . . . . . . . . . . . . . . . . . R304 | CHILD CARE | |||||
| Planning. . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 3 Plumbing fixture clearances. . . . . . . . . . . . . . . . R307 |
Defined. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 CLAY |
° | ° | |||
| Protection of wood against decay . . . . . . . . . . . R317 | Tiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.3 | |||||
| Ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.8 | CLEANOUT | |||||
| Sanitation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R306 | Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | |||||
| Site address. . . . . . . . . . . . . . . . . . . . . . . . . . . . R319 | Masonry chimney. . . . . . . . . . . . . . . . . . . . R1003.17 | ° | ° | |||
| Smoke alarms . . . . . . . . . . . . . . . . . . . . . . . . . . R314 | CLEARANCE | |||||
| Solar energy systems . . . . . . . . . . . . . . . . . . . . R324 Stairways . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7 Stationary storage battery systems . . . . . . . . . . R328 |
For chimneys . . . . . . . . . . . . . . . . . . . . . . . R1003.18 CLIMATE ZONE_ . . . .R202, R702.7.2, Table R702.7(5)_ COLUMNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R407 |
° ° ° ° |
° ° ° ° |
|||
| ° | ° | Storm shelters . . . . . . . . . . . . . . . . . . . . . . . . . . R323 Termite protection . . . . . . . . . . . . . . . . . . . . . . . R318 |
COMBUSTIBLEMATERIAL Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 |
| Sewer, definition . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILDING OFFICIAL |
CARPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . R309.2 CEILING |
° | ||||
|---|---|---|---|---|---|---|
| ° ° |
° ° |
Toilet, bath and shower spaces . . . . . . . . . . . . . R307 BUILDING THERMAL ENVELOPE Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILDING-INTEGRATED PHOTOVOLTAIC ROOF PANEL As roof covering. . . . . . . . . . . . . . . . . . . . . . R324.5.2 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 BUILT-UP ROOFING (see ROOFING) |
COMBUSTION AIR Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 COMMON VENT Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 CONCRETE Capillary break . . . . . . . . . . . . . . . . . . . . . R506.2.3.1 Compressive strength . . . . . . . . . . . . . . . . . . R402.2 Floors (on ground) . . . . . . . . . . . . . . . . . . . . . . . R506 |
° ° |
° ° |
|
| Tile (roof) . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.3 | ||||||
| ° | ° | C CARBON MONOXIDE ALARMS . . . . . . . . . . . . . R315 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 |
Weathering. . . . . . . . . . . . .Figure R301.2(1), R402.2 CONDITIONED FLOOR AREA . . . . . . . . . . . . . . R202 CONDITIONED SPACE . . . . . . . . . . . . . . . . . . . . R202 |
° ° |
° ° |
INDEX-2 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
DESIGN CRITERIA . . . . . . . . . . . . . . . . . . . . . . . R301
| Alternative provisions . . . . . . . . . . . . . . . . . R301.1.1 | ||
|---|---|---|
| Application . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.1 | ||
| Climatic and geographic . . . . . . . . . . . . . . . . . R301.2 | ||
| Dead load . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.4 | ||
| Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.6 | ||
| Engineered design . . . . . . . . . . . . . . . . . . . R301.1.3 | ||
| Live load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.5 | ||
| Nominal sizes . . . . . . . . . . . . . . . . . . . . . . . . . R301.8 | ||
| Roof load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.6 | ||
| Seismic . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.2.2 | ||
| Snow loads . . . . . . . . . . . . . . . . . . . . . . . . . R301.2.3 | ||
| Story height. . . . . . . . . . . . . . . . . . . . . . . . . . . R301.3 | ||
| Sunrooms . . . . . . . . . . . . . . . . . . . . . . . R301.2.1.1.1 | ||
| Wind . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.2.1 | ||
| DOORS | ° | ° |
| Egress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.2 | ° | ° |
| Exterior . . . . . . . . . . . . . . . . . . . . . . . . .R311.3, R609 DRAFT HOOD |
° | ° |
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| DRAFTSTOPPING . . . . . . . . . . . . . R302.12, R502.12 DRAINAGE |
° | ° |
| Foundation . . . . . . . . . . . . . . . . . . . . . . . . . . . . R405 | ° | ° |
| Inspection and tests . . . . . . . . . . . . . . . . . . . . .P2503 | ||
| Site drainage. . . . . . . . . . . . . . . . . . . . . . . . . . . R300 DUCTS |
° | ° |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ° | ° |
| Dwelling-garage wall and ceiling penetration . . . . . . . . . . . . . . . . . . R302.5.2 System, definition . . . . . . . . . . . . . . . . . . . . . . . R202 DWELLING |
° ° |
° ° |
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 DWELLING UNIT |
° | ° |
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Live/work unit defined . . . . . . . . . . . . . . . . . . . . R202 |
° | ° |
| Separation. . . . . . . . . . . . . . . . . . . . . R302.2, R302.3 | ° ° |
° ° |
E
ELEVATORS AND PLATFORM LIFTS . . . . . . . R321 EMERGENCY ESCAPE AND
RESCUE OPENINGS . . . . . . . . . . . . . . . . . . . . R310 Area wells . . . . . . . . . . . . . . . . . . . . . . . . . . R310.3.2 At additions . . . . . . . . . . . . . . . . . . . . . . . . . . . R310.6 At existing basements. . . . . . . . . . . . . . . . . . . R310.7 Bars, grilles, covers and screens . . . . . . . . R310.4.4 Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . R310.2 Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R310.3 Replacement window sill height . . . . . . . . . . . R310.5
sting basements. . . . . . . . . . . . . . . . . . . R310.7 Bars, grilles, covers and screens . . . . . . . . R310.4.4 Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . R310.2 Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R310.3 Replacement window sill height . . . . . . . . . . . R310.5
| � | CONNECTOR Vent, definition . . . . . . . . . . . . . . . . . . . . . . . . . .R202 |
|---|---|
| ° | Vent, definition . . . . . . . . . . . . . . . . . . . . . . . . . .R202 CONSTRUCTION |
| Cavity wall masonry . . . . . . . . . . . . . . . . . . . . . .R608 | |
| Flood-resistant . . . . . . . . . . . . . . . . . . . . . . . . . .R322 | |
| Floors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 5 | |
| Footings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R403 | |
| Foundation material . . . . . . . . . . . . . . . . . . . . . .R402 | |
| Foundation walls. . . . . . . . . . . . . . . . . . . . . . . . .R404 | |
| Foundations . . . . . . . . . . . . . . . . . . . . . . . . Chapter 4 | |
| Masonry . . . . . . . . . . . . . . .R606, R607, R608, R610 | |
| Pollutant control . . . . . . . . . . . . . . . . . . . . . . . . .R340 | |
| Roofs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 8 | |
| Steel framing . . . . . . . . . . . . . . . . R505, R603, R804 | |
| Walls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 6 | |
| Waste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R334.1 | |
| Wood framing . . . . . . . . . . . . . . . . R502, R602, R802 | |
| ° ° ° |
CONSTRUCTION DOCUMENTS . . . . . . . . . . . . .R106 CONTINUOUS AIR BARRIER . . . . . . . . . . . . . . .R202 CONTINUOUS WASTE |
| ° | Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 COURT |
|---|---|
| ° | Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 COVERING |
| Exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R703 | |
| Interior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R702 | |
| Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 9 | |
| Wall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 7 | |
| ° | CRAWL SPACE . . . . . . . . . . . . . . . . . . . . . . . . . .R408 Wall (definition). . . . . . . . . . . . . . . . . . . . . . . . . .R202 |
| ° | CROSS CONNECTION Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 |
D
| DAMPER, VOLUME Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
|---|---|---|
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| DAMPROOFING . . . . . . . . . . . . . . . . . . . . . . . . . .R406 | ||
| DAY-CARE | ||
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| Large family day-care homes . . . . . . . . . . . . . . .R336 | ||
| DECAY | ||
| Protection against. . . . . . . . . . . . . . . . . . . . . . . .R317 | ||
| DECK | ||
| Supported by exterior wall . . . . . . . . . . . . . . . . .R507 | ||
| ° | ° | Wood/plastic composite boards . . . . . . . . . .R507.2.2 DEFINITIONS |
| ° | ° | Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 Mechanical system . . . . . . . . . . . . . . . . . . . . . . .R202 |
| Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 |
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
| Under decks and porches . . . . . . . . . . . . . . R310.2.4 | ||
|---|---|---|
| Where required . . . . . . . . . . . . . . . . . . . . . . . R310.1 | ||
| ° | ° | EMERGENCY HOUSING_ . . . . . . . . . . . . . Appendix AZ_ ENERGY ANALYSIS, ANNUAL |
| ° | ° | Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 ENERGY COST |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| ° ° |
° ° |
Energy Rating Index . . . . . . . . . . . . . . . . . . . . . R202 ENERGY STORAGE SYSTEMS . . . . . . . . . . . . . R328 |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Documentation and labeling . . . . . . . . . . . . R328.11 | ||
| Electric vehicle use . . . . . . . . . . . . . . . . . . . R328.10 | ||
| Figure: ESS vehicle impact protection. . . . . R328.8.1 | ||
| Fire detection . . . . . . . . . . . . . . . . . . . . . . . . . R328.7 | ||
| Protection from vehicle impact. . . . . . . . . . . . R328.8 | ||
| Toxic and highly toxic gas . . . . . . . . . . . . . . R328.12 | ||
| Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . R328.9 | ||
| ENTRY_ . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8.5_, R104.6 | ||
| ENVELOPE, BUILDING THERMAL | ||
| ° | ° | Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 EXTERIOR |
| Balconies and elevated walking surfaces . . R106.1.6 | ||
| Covering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703 | ||
| Insulation_and_ finish systems. . . . . . . . . . . . . R703.9 | ||
| Lath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.7.1 | ||
| Plaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.7 | ||
| EXTERIOR WALL | ||
| Construction. . . . . . . . . . . . . . . . . . . . . . . . . . R302.1 | ||
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| ° | ° | Fire-resistance rating . . . . . . . . . . . . . . . . . . . R302.1 |
| F |
Minimum Water Meter
Pressure Loss. . . . . . . . . . . . . . . Table R313.3.5.2
| Shutoff valve prohibited_ . . . . . . . . . . . . . . R313.3.3.2_ FIREBLOCKING |
° | ° |
|---|---|---|
| Barrier between stories . . . . . . . . . .R302.11, R602.8 | ||
| Chimney. . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.19 | ||
| Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . R1001.12 | ||
| FIREPLACES . . . . . . . . . . . . . . . . . . . . . . . Chapter 10 | ||
| Clearance. . . . . . . . . . . . . . . . . . . . . . . . . . R1001.11 | ||
| Corbeling . . . . . . . . . . . . . . . . . . . . . . . . . . . R1001.8 Factory-built . . . . . . . . . . . . . . . . . . . . . . . . . . . R1004 |
° | ° |
| Fireblocking . . . . . . . . . . . . . . . . . . . . . . . . R1001.12 | ||
| Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1001.5 | ||
| FIRE-RESISTANT CONSTRUCTION. . . . . . . . . . R302 | ||
| Draftstopping . . . . . . . . . . . . . . . . . . . . . . . . . R302.1 | ||
| Dwelling-garage fire separation . . . . . . . . . . . R302.6 | ||
| Dwelling-garage opening and penetration . . . R302.5 | ||
| Exterior walls . . . . . . . . . . . . . . . . . . . . . . . . . R302.1 | ||
| Fireblocking . . . . . . . . . . . . . . . . . . . . . . . . . R302.11 | ||
| Floors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R302.13 | ||
| Foam plastics. . . . . . . . . . . . . . . . . . . . . . . . . R302.8 | ||
| Insulation . . . . . . . . . . . . . . . . . . . .R302.10, R302.14 | ||
| Penetrations. . . . . . . . . . . . . . . . . . . . . . . . . . R302.4 | ||
| Townhouse separation. . . . . . . . . . . . . . . . . . R302.2 | ||
| Two-family dwellings . . . . . . . . . . . . . . . . . . . R302.3 | ||
| Under-stair protection. . . . . . . . . . . . . . . . . . . R302.7 | ||
| Wall and ceiling finishes. . . . . . . . . . . . . . . . . R302.9 | ||
| FIRE-SEPARATION DISTANCE | ||
| Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Exterior walls and wall projections . . . . . . . . . R302.1 | ||
| Ground-mounted photovoltaic systems . . . . . R324.7 FIXTURE UNIT |
° | ° |
| Drainage, definition . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Water supply, definition . . . . . . . . . . . . . . . . . . . R202 | ||
| FIXTURES | ||
| Clearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . R307.1 | ||
| Plumbing fixture, definition. . . . . . . . . . . . . . . . . R202 FLAME SPREAD INDEX . . . . . . . . . .R302.9, R302.10 |
° | ° |
| FLASHING . . . . . . . . R703.4, R703.8.5, R903.2, R905 FLOOD PROTECTION PLAN |
° | ° |
| Areas protected by the facilities of Central Valley . . . . . . . . . . . . . . . . .Appendix AY |
||
| FLOOD-RESISTANT CONSTRUCTION | ||
| General and structural . . . . . . . . . . . .R301.2.4, R322 FLOORS |
° | ° |
| Bathtub and shower . . . . . . . . . . . . . . . . . . . . R307.2 | ° | ° |
| Concrete (on ground). . . . . . . . . . . . . . . . . . . . . R506 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . R301, R501.2 |
° | ° |
| Steel framing . . . . . . . . . . . . . . . . . . . . . . . . . . . R505 | ||
| Treated-wood (on ground) . . . . . . . . . . . . . . . . . R504 | ||
| Wood framing. . . . . . . . . . . . . . . . . . . . . . . . . . . R502 |
| � | � | F |
|---|---|---|
| ° | FACTORY BUILT | |
| ° | ° | Chimneys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1005 |
| Fireplace stoves. . . . . . . . . . . . . . . . . . . . . . R1005.3 | ||
| Fireplaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1004 | ||
| ° | ° | FASTENING . . . . . . . . . . . . . . . . . . . . Table R602.3(1) FEES, PERMIT . . . . . . . . . . . . . . . . . . . . . . . . . . . R108 |
| ° ° |
° ° |
FENESTRATION Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 |
| ° | ° | Vertical defined . . . . . . . . . . . . . . . . . . . . . . . . . R202 FENESTRATION, SITE-BUILT |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| FINISHES |
| Under decks and porches . . . . . . . . . . . . . . R310.2.4 | ||
|---|---|---|
| Flame spread and smoke density . . . . . . . . . R302.9 | ||
| For ceilings . . . . . . . . . . . . . . . . . . . . . . . . . . . . R805 | ||
| Interior . . . . . . . . . . . . . . . . . . . . R302.9, R315, R702 | ||
| ° | ° | FIRE SPRINKLER SYSTEM . . . . . . . . . . . . . . . . R313 |
| Ceiling configurations . . . . . . . . . . . . . R313.3.4.1.1, R313.3.4.1.2, R313.3.4.1.3 |
||
| ° | Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . R313.3.4.1 |
INDEX-4 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
HAND SHOWER (see SHOWER) HANDRAILS . . . . . . . . . . . . . . . . . R311.7.8, R311.8.3
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 HEADERS
SIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R610.8 Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R603.6 Wood. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R602.7 HEARTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1001.9
Extension . . . . . . . . . . . . . . . . . . R1001.9, R1001.10 HEATED SLAB
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 HEATERS
Masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1002 HEATING
Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . R303.10 HEIGHT
Ceiling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R305 HIGH-EFFICACY LAMPS
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 HISTORIC BUILDING
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 HOLLOW-UNIT MASONRY (see MASONRY) HORIZONTAL
Pipe, definition . . . . . . . . . . . . . . . . . . . . . . . . . R202
| FLUE | |
|---|---|
| Area . . . . . . . . . . . . . . . . . . . . . R1003.14, R1003.15 | |
| Lining . . . . . . . . . . . . . . . . . . . . R1003.11, R1003.12 | |
| Multiple . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.13 | |
| ° ° ° |
FOAM PLASTICS . . . . . . . . . . . . . . . . . . . . . . . . .R316 FOOTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R403 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .R403 FOUNDATIONS. . . . . . . . . . . . . . . . . . . . . . . Chapter 4 |
| Cripple walls . . . . . . . R602.9, R602.10.9, R602.11.2 | |
| Frost protection. . . . . . . . . . . . . . . . . . . . . R403.1.4.1 | |
| ° | Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . .R109.1.1 Walls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R404 |
| FRAME | |
| ° | Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . .R109.1.4 |
INDIRECTLY CONDITIONED SPACE
(see CONDITIONED SPACE)
| INDIVIDUAL | ||
|---|---|---|
| Sewage disposal systems. . . . . . . . . . . R202, P2602 INFILTRATION |
° ° |
° ° |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ° | ° |
| INFLATABLE AMUSEMENT DEVICE | ||
| _ Defined. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202_ | ||
| INLET | ||
| To masonry chimneys. . . . . . . . . . . . . . . . . R1003.16 | ||
| INSPECTION | ||
| On-site_ . . . . . . . . . . . . . . . . . . . . . . . . . 1.8.4,_R109.1 | ° | ° |
| INSTALLATION | ||
| Of flue liners . . . . . . . . . . . . . . . . . . . . . . . . R1003.12 | ° | ° |
| INSULATING SHEATHING | ° | ° |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| INSULATION | ° | ° |
| Above-deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . R906 | ||
| Air-impermeable . . . . . . . . . . . . . . . . . . . . . . . . R202 Flame spread . . . . . . . . . . . . . . . . . . . . . . . . R302.10 Foam plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . R316 INTERIOR |
° ° ° ° |
° ° ° ° |
| Lath. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.2.3 |
| G GARAGES AND CARPORTS. . . . . . . . . . . . . . . .R309 | ||
|---|---|---|
| GARAGES AND CARPORTS. . . . . . . . . . . . . . . .R309 | ||
| Electric vehicle charging infrastructure. . . . . . R309.8 | ||
| ° | ° | Protection of Energy Storage Systems. . . . . . R328.8 GIRDERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R502.5 |
| ° | ° | GLASS MAT GYPSUM PANEL . . . . . . . . . . . . . .R202 GLAZING |
| Aggregate area. . . . . . . . . . . . . . . . . . . . . . . . R303.1 | ||
| Greenhouses, glass in . . . . . . . . . . . . . . . . .R308.6.6 | ||
| Protection of openings . . . . . . . . . . . . . . . R301.2.1.2 | ||
| Required glazed openings . . . . . . . . . . . . . . . R303.9 | ||
| Safety glazing and hazardous locations . . . . . . .R308 | ||
| Site-built . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R308.5 | ||
| Skylights and sloped. . . . . . . . . . . . . . .R202, R308.6 | ||
| GRADE | ||
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| Of lumber . . . . . . . . . . R502.1.1, R602.1.1, R802.1.1 | ||
| Plane, definition . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| ° ° ° |
° ° ° |
Slope of piping, definition . . . . . . . . . . . . . . . . . .R202 GROUND Floors (on ground) . . . . . . . . . . . . . . . . . R504, R506 GUARDSOR GUARDRAIL . . . . . . . . . . . . . . . . .R312 |
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| Exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R507.10 | ||
| GYPSUM | ||
| Wallboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.3 | ||
| GYPSUM SHEATHING . . . . . . . . . . . . . . . . . . . . .R202 | ||
| GYPSUM WALLBOARD. . . . . . . . . . . . . . . . . . . .R202 | ||
| H | ||
| HABITABLE ATTIC. . . . . . . . . . . . . . . . . . . . . . . .R326 | ||
| HABITABLE SPACE | ||
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| HALLWAYS. . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.6 |
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
Figure R301.2(3) Wind speed map . . . . . . . . . . . . . . .Figure R301.2(2) LOADS
Horizontal load . . . . . . . . . . . . . . . Appendix AE123.1 LUMBER
Grade . . . . . . . . . . . . . R502.1.1, R602.1.1, R802.1.1
M
MANUFACTURED HOME
Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Provisions. . . . . . . . . . . . . . . . . . . . . . . .Appendix AE MASONRY
Anchorage . . . . . . . . . . . . . . . . . . . . . . . . . . R606.11 Cavity wall . . . . . . . . . . . . . . . . . . . . . . . . . . R606.13 Chases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R606.8 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R606 Hollow unit . . . . . . . . R202, R606.3.2.2, R606.13.1.2 Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . R109.1.4 Seismic requirements. . . . . . . . . . . . . . . . . . R606.12 Solid, definition. . . . . . . . . . . . . . . . . . . . . . . . . . R202 Veneer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.8 Veneer attachment. . . . . . . . . . . . . . . . . . . . . R703.3 MATERIALS
Alternate. . . . . . . . . . . . . . . . . . . . . . . 1.8.7, R104.11 Combustible . . . . . . . . . .R202, R1001.11, R1001.12,
R1003.18, R1003.19 For flue liners . . . . . . . . . . . . . . . . . . . . . . . R1003.11 For hearth extension . . . . . . . . . . . . . . . . . . R1001.9 For siding . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.5 MEANS OF EGRESS . . . . . . . . . . . . . . . . . . . . . . R311
Attachment of landings, decks,
balconies and stairs . . . . . . . . . . . . . . . . . . R311.5 Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.2 Floors and landings at exterior doors. . . . . . . R311.3 Hallways. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.6 Ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.8 Stairways . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7 Vertical egress . . . . . . . . . . . . . . . . . . . . . . . . R311.4 MECHANICAL
Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . R109.1.2
INDEX
LOAD
Additional . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.8 Dead load. . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.4 Definition, dead and live. . . . . . . . . . . . . . . . . . . R202 Live load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.5 Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.6 Seismic risk map . . . . . . . . . . . Figure R301.2.2.1(1),
Figure R301.2.2.1(2), Figure R301.2.2.1(3), Figure R301.2.2.1(4), Figure R301.2.2.1(5),
Figure R301.2.2.1(6) Snow load map . . . . . . . . . . . . . . . Figure R301.2(1),
| Other finishes. . . . . . . . . . . . . . . . . . . . . . . . . R702.5 | |
|---|---|
| Plaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.2 | |
| ° ° |
Wall covering . . . . . . . . . . . . . . . . . . . . . . . Chapter 7 INTERMODAL SHIPPING CONTAINER . . . . . . . . . . . . . . . . . . . . R202, R301.2 |
| ° | J JOIST |
| ° | Bearing . . . . . . . . . . . . . . . . . . . .R502.6, R606.6.3.1 |
| K | |
| KITCHEN | |
| ° ° |
Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 L LABELED |
| ° ° ° ° |
Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 LABELING Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 Garage doors. . . . . . . . . . . . . . . . . . . . . . . . R609.4.1 LANDINGS . . . . . . . . . . . R311.3, R311.3.1, R311.3.2, |
| R311.7.6, R311.8.2 | |
| LATERAL SUPPORT. . . . R502.7, R606.6.4, R607.5.2 | |
| LATH | |
| Exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.7.1 | |
| ° | Interior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.2.3 LAVATORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . P2711 |
| ° | Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R307 LIABILITY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R104.8 |
| LIGHT, VENTILATION AND HEATING . . . . . . . . R303 | |
| LIGHTING | |
| Adjoining rooms . . . . . . . . . . . . . . . . . . . . . . . R303.2 | |
| ° | Bathrooms . . . . . . . . . . . . . . . . . . . . . . . . . . . R303.3 Exterior stairs. . . . . . . . . . . . . . . . . . . . . . . . . R303.8 |
| Habitable rooms. . . . . . . . . . . . . . . . . . . . . . . R303.1 | |
| ° ° |
Interior stairs . . . . . . . . . . . . . . . . . . . . . . . . . R303.7 Required glazed openings . . . . . . . . . . . . . . . R303.9 LIMITED-DENSITY OWNER-BUILT RURAL DWELLINGS |
| Alternative provisions. . . . . . . . . . . . . . . . R301.1.1.1 | |
| Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | |
| LINING | |
| Flue . . . . . . . . . . . . . . . . . . . . . .R1003.11, R1003.12 | |
| ° | LINTEL . . . . . . . .R606.10, R608.8, R703.8.3, R1001.7 LISTED AND LISTING |
| ° | Definition applied to building and mechanical provisions . . . . . . . . . . . . . . . . . . R202 LIVE/WORK UNIT . . . . . . . . . . . . . . . . . . . . . . . . R202 |
| Accessibility . . . . . . . . . . . . . . . . . . . . . . . . . . R320.2 |
INDEX-6 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
PIERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R606.7
Masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . R404.1.9 PLANNING
Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 3 PLANS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R106 PLASTER
Exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.7 Interior. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.2 PLATFORM LIFTS AND ELEVATORS . . . . . . . R321 PLENUM
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 PLUMBING
Fixture clearances. . . . . . . . . . . . . . . . . . . . . . . R307 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . R109.1.2 Requirements and definitions . . . . . . . . . . . . . . R202 System, definition . . . . . . . . . . . . . . . . . . . . . . . R202 PLYWOOD
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.5 Materials, walls . . . . . . . . . . . . . . . . . . . . . . . . . R604 POTABLE WATER
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 PRECAST CONCRETE
Footings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R403.4 Foundation material . . . . . . . . . . . . . . . . . . R402.3.1 Foundation walls. . . . . . . . . . . . . . . . . . . . . . . R404.5 PRIVATE
Sewage disposal system . . . . . . . . . . . . Appendix AI PROPOSED DESIGN (ENERGY) . . . . . . . . . . . . R202 PROTECTION
Against decay and termites. . . . . . . . . . . R317, R318 Against radon . . . . . . . . . . . . . . . . . . . . Appendix AF PURLINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . R802.4.5 PURPOSE . . . . . . . . . . . . . . . . . . . . . . .R1.1.2, R101.3 PUSH-FIT FITTING . . . . . . . . . . . . . . . . . . . . . . . R202
R
RADON
Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix AF RAFTERS
Grade of lumber . . . . . . . . . . . . . . . . . . . . . . . R802.1 Spans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R802.1.1,
Tables R802.4.1(1) – R802.4.1(8) READILY ACCESSIBLE
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 REPAIR
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 RESISTANT SIDING MATERIAL (see MATERIALS) RIDGE BOARD . . . . . . . . . . . . . . . . . . . . . . . . .R802.4
| MEMBRANE Penetration . . . . . . . . . . . . . . . . . . . . . . . . . .R302.4.2 | |
|---|---|
| Penetration . . . . . . . . . . . . . . . . . . . . . . . . . .R302.4.2 | |
| Polyethylene . . . . . . . . . . . . . . . . R504.2.2, R506.2.3 | |
| Waterproofing . . . . . . . . . . . . . . . . . . . . . . . . . R406.2 | |
| Water-resistive . . . . . . . . . . . . . . . . . . . . . . . . R703.2 | |
| ° | METAL Roof panels . . . . . . . . . . . . . . . . . . . . . . . . . R905.10 |
| ° | Roof shingles . . . . . . . . . . . . . . . . . . . . . . . . . R905.4 METHODS |
| Water distribution pipe sizing . . . . . . . . Appendix AP | |
| MEZZANINES . . . . . . . . . . . . . . . . . . . . . . . . . . . .R325 | |
| MODIFICATIONS . . . . . . . . . . . . . . . . . . . . . . R104.10 | |
| MOISTURE CONTENT, BUILDING MATERIALS_ . . . . . . . . . . . . .R109.1.4.1_ |
|
| MOISTURE CONTROL . . . . . . . . . . . . . . . . . . . R702.7 | |
| MORTAR | |
| ° ° ° |
Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R606.3.1 MULTIPLE Flues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1003.13 |
| N NONCOMBUSTIBLE MATERIAL | |
|---|---|
| NONCOMBUSTIBLE MATERIAL | |
| ° ° |
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 NOTCHING Steel joists . . . . . . . . . . . . . . . . .R505.2.5, R505.3.5, |
| R804.2.5, R804.3.3 | |
| Steel studs . . . . . . . . . . . . . . . . . R603.2.6, R603.3.4 | |
| Wood joists . . . . . . . . . . . . . . . . . . .R502.8, R802.7.1 | |
| Wood studs. . . . . . . . . . . . . . . . . . . . . . . . . . . R602.6 | |
| Wood top plates . . . . . . . . . . . . . . . . . . . . . .R602.6.1 |
O
| OCCUPIED SPACE | ||
|---|---|---|
| ° | ° | Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 OPENING |
| ° ° |
° ° |
Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . R302.5 P PARAPETS . . . . . . . . . . . . . . . . . . R302.2.2, R606.4.4 |
| PARTICLEBOARD | ||
| Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R503.3 | ||
| Walls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R605 | ||
| PENETRATIONS. . . . . . . . . . . . . . . . . R302.4, R302.5 | ||
| PERMITS_. . . . . . . . . . . . . . . . . . 1.8.4,_R105,R105.5.1 | ||
| PHOTOVOLTAIC PANEL SYSTEMS. . . . . . . . . .R907 | ||
| Ground-mounted definition . . . . . . . . . . . . . . . . .R202 | ||
| PHOTOVOLTAIC SUPPORT STRUCTURE, ELEVATED_ . . . . R202, R324.8, R324.8.1, R324.8.2_ |
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
| ROOF Coverings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905 | ||
|---|---|---|
| Coverings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905 | ||
| Coverings fire hazard severity zones. . . . . . R902.1.1 | ||
| Drainage . . . . . . . . . . . . . . . . . . . . . . . . . . . . R903.4 | ||
| Fire classification . . . . . . . . . . . . . . . . . . . . . . . . R902 | ||
| Flashing . . . . . . . . . . . . . . . . . R703.4, R903.2, R905 | ||
| Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R904 | ||
| Reroofing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R908 | ||
| Rooftop-mounted solar energy systems . . . . R324.3, | ||
| R324.6 | ||
| Steel framing . . . . . . . . . . . . . . . . . . . . . . . . . . . R804 | ||
| Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . R806.1 | ||
| Vents in the WUI . . . . . . . . . . . . . . . . . . . . . R806.1.1 | ||
| Wood framing . . . . . . . . . . . . . . . . . . . . . . . . . . R802 | ||
| ROOF ASSEMBLY | ||
| ° | ° | Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 ROOF-CEILING CONSTRUCTION (see CONSTRUCTION) |
| ROOFING | ||
| Built-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.9 | ||
| Liquid-applied coating . . . . . . . . . . . . . . . . . R905.15 | ||
| Modified bitumen . . . . . . . . . . . . . . . . . . . . . R905.11 | ||
| Sprayed polyurethane foam. . . . . . . . . . . . . R905.14 | ||
| Thermoplastic single-ply . . . . . . . . . . . . . . . R905.13 | ||
| Thermoset single-ply . . . . . . . . . . . . . . . . . . R905.12 | ||
| ROOM | ||
| ° ° |
° ° |
Area, height and dimensions . . . . . . . . . .R304, R305 Minimum Sizes . . . . . . . . . . . . . . . . . . . . . . . . . R304 |
| S SANITATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . R306 | |
|---|---|
| SANITATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . R306 | |
| SEISMIC RISK MAP. . . . . . . . . . . . . Figure R301.2(2), | |
| Figure R301.2(3) SEPTIC TANK |
|
| ° | Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 SEWER, BUILDING |
| ° | Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 SHAKES |
| Wood . . . . . . . . . . . . . . . . . . R702.6, R703.6, R905.8 | |
| SHINGLE | |
| Asphalt shingles. . . . . . . . . . . . . . . . . . . . . . . R905.2 | |
| Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.4 | |
| Slate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.6 | |
| Wood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.7 | |
| SHOWER | |
| ° ° ° |
Compartment . . . . . . . . . . . . . . . . . . . . . . . . . R307.2 Finishes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R307.2 Space required . . . . . . . . . . . . . . . . . . . . . . . R307.1 SHUTOFF VALVE (see VALVES) |
| Shutoff valves prohibited_ . . . . . . . . . . . . . R313.3.3.2_ |
SIDING Exterior coverings . . . . . . . . . . . . . . . . . . . . . . . R703
| Exterior coverings . . . . . . . . . . . . . . . . . . . . . . . R703 | ||
|---|---|---|
| Insulated defined . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| SITE | ° | ° |
| Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R319 | ||
| Preparation. . . . . . . . . . . . . .R408.5, R504.2, R506.2 | ||
| SIZE | ||
| Of rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R304 | ° | ° |
| SKYLIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . R308.6 | ° | ° |
| SLATE SHINGLES . . . . . . . . . . . . . . . . . . . . . . R905.6 | ||
| SLEEPING UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| SMOKE ALARMS. . . . . . . . . . . . . . . . . . . . . . . . . R314 | ||
| SMOKE-DEVELOPED INDEX . . . . . .R302.9, R302.10 | ||
| SNOW LOAD MAP. . . . . . . . . . . . . . Figure R301.2(3), | ||
| Figure R301.2(4) SOFFIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R704 |
° | ° |
| Fiber-cement . . . . . . . . . . . . . . . .R704.2.2, R704.3.2 | ||
| Hardboard . . . . . . . . . . . . . . . . . .R704.2.3, R704.3.3 | ||
| Vinyl . . . . . . . . . . . . . . . . . . . . . . .R704.2.1, R704.3.1 | ||
| Wood . . . . . . . . . . . . . . . . . . . . . .R704.2.4, R704.3.4 | ||
| SOILS | ||
| Collapsible (definition) . . . . . . . . . . . . . . . . . . . . R202 | ||
| Compressible (definition) . . . . . . . . . . . . . . . . . . R202 | ||
| Expansive (definition). . . . . . . . . . . . . . . . . . . . . R202 | ||
| SOLAR ENERGY SYSTEMS . . . . . . . . . . . . . . . . R324 Building-integrated photovoltaic systems. . . . R324.5 |
° | ° |
| Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Ground-mounted photovoltaic systems . . . . . R324.7 | ||
| Photovoltaic systems . . . . . . . . . . . . . . . . . . . R324.3 | ||
| Roof access and pathways . . . . . . . . . . . . . . R324.6 | ||
| Rooftop-mounted photovoltaic systems. . . . . R324.3 | ||
| Solar thermal systems . . . . . . . . . . . . . . . . . . . . R202 SOLAR HEAT GAIN COEFFICIENT (SHGC) Defined. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 |
° ° ° |
° ° ° |
| SPANS | ° | ° |
| Steel (allowable). . . . . . . . . . . . R505.3.2, R804.3.2.1 | ||
| Wood (allowable) . . . . . . . . . . . . . . . .R502.3, R802.5 SPRINKLER (see FIRE SPRINKLER SYSTEMS) |
° | ° |
| STAIRWAYS. . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7 | ||
| Alternating tread devices . . . . . . . . . . . . . . R311.7.11 | ||
| Bulkhead enclosure . . . . . . . . . . . . . . . . R311.7.10.2 | ||
| Handrails . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.8 | ||
| Headroom . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.2 | ||
| Illumination. . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.9 | ||
| Landings for . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.6 | ||
| Nosings . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.5.3 | ||
| Ship’s ladders. . . . . . . . . . . . . . . . . . . . . . . R311.7.12 | ||
| Spiral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.10 | ||
| Treads and risers . . . . . . . . . . . R311.7.5, R311.7.5.4 | ||
| Vertical rise . . . . . . . . . . . . . . . . . . . . . . . . . R311.7.3 | ||
| Walking surface slope . . . . . . . . . . . . . . . . . R311.7.7 |
INDEX-8 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
| Walkline . . . . . . . . . . . . . . . . . . . . . . . . . . . .R311.7.4 | ||
|---|---|---|
| Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R311.7.1 | ||
| Winder treads . . . . . . . . . . . . . . . . . . . . .R311.7.5.2.1 | ||
| STANDARD REFERENCE DESIGN | ||
| ° ° |
° ° |
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 STANDARDS . . . . . . . . . . . Chapter 44, Appendix AG STATIONARY ENGINE GENERATORS . . . . . . .R329 |
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| STATIONARY FUEL CELL POWER SYSTEMS . . . . . . . . . . . . . . . . . . . . . .R330 |
||
| Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 | ||
| STEEL | ||
| Fireplace units . . . . . . . . . . . . . . . . . . . . . .R1001.5.1 | ||
| ° | ° | Floor construction . . . . . . . . . . . . . . . . . . . . . . . .R505 Roof-ceiling construction . . . . . . . . . . . . . . . . . .R804 |
| Walls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R603 | ||
| STOP WORK ORDER. . . . . . . . . . . . . . . . . . . . . .R114 | ||
| STORM SHELTERS . . . . . . . . . . . . . . R106.1.5, R323 | ||
| STORY | ||
| ° ° |
° ° |
Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 STRAWBALE CONSTRUCTION . . . . . . Appendix AS STRUCTURAL INSULATED PANEL (SIP) . . . . .R610 |
| STUDS | ||
| Spacing. . . . . . . . . . . . . . . . . . . . . . . . . . . . .R602.3.1 | ||
| Steel . . . . . . . . . . . . . . . . . . . . . . . . . R603.2, R603.3 | ||
| ° | ° | Wood . . . . . . . . . . . . . . . . . . . . . . . . R602.2, R602.3 SUNROOMS . . . . . . . . . . . . . . R301.2.1.1.1, R303.9.1 |
| ° | ° | Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 SUPPORT |
| ° | ° | Of decks . . . . . . . . . . . . . . . . . . . . . . . . . . R507.9.1.2 Of floor joists. . . . . . . . . . . . . . . . . .R502.6, R505.3.2 |
| ° ° ° |
° ° ° |
Of masonry chimneys. . . . . . . . . .R1003.2, R1003.3, R1003.4 SWIMMING POOLS, SPAS AND HOT TUBS . . . . . . . . . . . . . . . . . . . . . . Appendix_AX_ |
TIES
| Veneer . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.8.4 | ||
|---|---|---|
| TILE | ||
| Shingles (clay and concrete). . . . . . . . . . . . . . R905.3 TODDLER |
° | ° |
| _ Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202_ | ||
| TOILET, BATH AND SHOWER SPACES. . . . . . R307 | ||
| TOWNHOUSE | ||
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Parapet construction. . . . . . . . . . . . . . . . . . R302.2.5 | ||
| Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R101.2 | ||
| Separation. . . . . . . . . . . . . . . . . . . . . . . . . . . . R302.2 | ||
| Structural independence. . . . . . . . . . . . . . . R302.2.6 TRAP |
° | ° |
| Arm, definition. . . . . . . . . . . . . . . . . . . . . . . . . . R202 TRUSSES |
° ° |
° ° |
| Steel . . . . . . . . . . . . . . . . . . . . . . R505.1.3, R804.3.6 | ||
| Wood. . . . . . . . . . . . . . . . . . . . . . . R502.11, R802.10 | ||
| TWO-FAMILY DWELLINGS . . . . . . . . . . . . . . . R302.3 U UNDER FLOOR |
° ° |
° ° |
| Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R408 UNDER-STAIR PROTECTION . . . . . . . . . . . . . R302.7 |
° ° |
° ° |
| UNVENTED ATTIC ASSEMBLIES . . . . . . . . . . R806.5 | ° |
T
TANK
Septic, definition . . . . . . . . . . . . . . . . . . . . . . . . .R202 TEMPORARY STRUCTURES . . . . . . . . . . . . . . .R107 TERMINATION
Of chimneys . . . . . . . . . . . . . . . . . . . . . . . . . R1003.9 TERMITES
Infestation probability map . . . . . . . . . Figure R318.4 Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R318 THERMAL ISOLATION
Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R202 THERMAL RESISTANCE (see R -VALUE) THICKNESS
Of chimney walls . . . . . . . . . . . . . . . . . . . . R1003.10
INDEX
VAPOR RETARDERS. . . . . . . . . . . . . . . . . . . . R702.7
| Capillary break . . . . . . . . . . . . . . . . . . . . . R506.2.3.1 | ||
|---|---|---|
| Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Under floor . . . . . . . . . . . . . . . . . . . . . . . . . . . R408.8 | ||
| VENEER | ||
| Masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R703.7 | ||
| VENT | ||
| Plumbing system, definition . . . . . . . . . . . . . . . R202 VENTILATION |
° ° |
° ° |
| Adjoining rooms . . . . . . . . . . . . . . . . . . . . . . . R303.2 | ||
| Bathroom and kitchen. . . . . . . . . . . . . . . . . . . R303.3 | ||
| Habitable rooms . . . . . . . . . . . . . . . . . . . . . . . R303.1 | ° | ° |
| Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R806 | ||
| Under floor . . . . . . . . . . . . . . . . . . . . . . . . . . . R408.1 | ||
| VENTING (MECHANICAL) | ° | ° |
| Chimney and vent connectors . . . . . . . . . . . . R1006 Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R1006 VERTICAL |
° ° ° |
° ° ° |
| Pipe, definition . . . . . . . . . . . . . . . . . . . . . . . . . R202 | ° | ° |
| VIOLATIONS | ||
| And penalties . . . . . . . . . . . . . . . . . . . . . . . . . . R113 | ||
| VISIBLE TRANSMITTANCE (VT) Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202 |
° ° |
° ° |
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
INDEX
W
Standards of quality . . . . . . . . . . . . . . . . . . . . R337.3 Vents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R337.6 WIND
Design criteria . . . . . . . . . . . . . . . . . . . . . . . . R301.2 Speed maps. . . . . . . . . . . . . . . . . Figure R301.2(5)A,
Figure R301.2(5)B WINDOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R609
EERO replacement sill height . . . . . . . . . . . . R310.5 Fall protection. . . . . . . . . . . . . . . . . . . . . . . . . R312.2 Opening limiting devices . . . . . . . . . . . . . . . R312.2.2 WOOD
Floor construction. . . . . . . . . . . . . . . . . . . . . . . . R502 Foundation walls . . . . . . . . . . . . . . . . . . . . . . R404.2 Protection against decay . . . . . . . . . . . . . . . . . . R317 Roof-ceiling construction . . . . . . . . . . . . . . . . . . R802 Shakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.8 Shingles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R905.7 Trusses . . . . . . . . . . . . . . . . . . . . .R502.11, R802.10 Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R602
Y
YARD
Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R202
| � | � | WALLBOARD Gypsum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.3 |
|---|---|---|
| Gypsum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R702.3 | ||
| WALLS | ||
| Above-grade, defined . . . . . . . . . . . . . . . . . . . . R202 | ||
| Basement, defined. . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| ° | ° | Bathtub compartments. . . . . . . . . . . . . . . . . . R307.2 |
| Bracing, steel . . . . . . . . . . . . . . . . . . . . . . . . . R603.9 | ||
| Bracing, wood . . . . . . . . . . . . . . . . . . . . . . . R602.10 | ||
| Construction. . . . . . . . . . . . . . . . . . . . . . . . Chapter 6 | ||
| Covering . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 7 | ||
| Crawl space, defined . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Cripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R602.9 | ||
| Deflection. . . . . . . . . . . . . . . . . . . . . . . . . . . . R301.7 | ||
| Exterior, defined. . . . . . . . . . . . . . . . . . . . . . . . . R202 | ||
| Exterior covering . . . . . . . . . . . . . . . . . . . . . . . . R703 | ||
| Finishes . . . . . . . . . . . . . . . . . . . . . . . . R307.2, R702 | ||
| Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . R1001.5 | ||
| Foundation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . R404 | ||
| ° | ° | Insulating concrete form . . . . . . . . . R608.3, R608.4, R608.5.3 Steel framing . . . . . . . . . . . . . . . . . . . . . . . . . . . R603 |
| Structural insulated panels (SIP) . . . . . . . . . . . . R610 | ||
| Thickness, masonry chimneys. . . . . . . . . . R1003.10 | ||
| Wood framing . . . . . . . . . . . . . . . . . . . . . . . . . . R602 | ||
| WUI: Exterior wall assembly, defined . . . . . . . . . . . . . . . . . . . . . . R202, R337.2 |
||
| ° ° |
° ° |
WUI: Exterior wall covering, _defined . . . . . . . . . . . . . . . . . . . . . . R202, R337._2 WASTE Construction waste . . . . . . . . . . . . . . . . . . . . . . R334 |
| ° | ° | Continuous, definition . . . . . . . . . . . . . . . . . . . . R202 WATER |
| Distribution system, definition . . . . . . . . . . . . . . R202 | ||
| ° | ° | Heater, definition . . . . . . . . . . . . . . . . . . . . . . . . R202 Supply system, definition . . . . . . . . . . . . . . . . . . R202 |
| ° ° |
° ° |
WATER CLOSET Clearances for . . . . . . . . . . . . . . . . . . . . . . . . R307.1 WATERPROOFING |
| ° | And dampproofing . . . . . . . . . . . . . . . . . . . . . . . R406 WILDLAND-URBAN INTERFACE |
|
| Accessory buildings and miscellaneous structures . . . . . . . . . . . . . R337.10 |
||
| Definitions . . . . . . . . . . . . . . . . . . . . . . R202, R337.2 | ||
| Decking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R337.9 | ||
| Exterior covering . . . . . . . . . . . . . . . . . . . . . . R337.7 | ||
| Exterior windows, skylights and doors. . . . . . R337.8 | ||
| Ignition-resistant construction . . . . . . . . . . . . R337.4 | ||
| Materials and construction methods for exterior wildfire exposure . . . . . . . . . . . . . . . . R337 |
||
| Roofing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R337.5 |
INDEX-10 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
HISTORY NOTE APPENDIX
California Code of Regulations, Title 24, Part 2.5
HISTORY:
For prior code history, see the History Note Appendix to the California Residential Code, 2019 Triennial Edition, effective January 1, 2020.
- (BSC 06/21, CEC 03/21, HCD 06/21, SFM 05/21)— Adoption by reference of the 2021 International Residential Code with necessary amendments to become the 2022 California Residential Code, and repeal of the 2018 edition of the International Residential Code ; effective on January 1, 2023.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
HIST-2 2022 CALIFORNIA RESIDENTIAL CODE
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
Authored by code experts, these useful tools are “must-have” guides to the many important changes in the 2022 California Codes. Key changes are identified then followed by in-depth, expert discussion of how the change affects real world application. A full-color photo, table or illustration is included for each change to further clarify application.
Significant Changes to the California Building Code, 2022 Edition Search #5521S22
Significant Changes to the California Residential Code, 2022 Edition Search #5526S22
Significant Changes to the California Fire Code, 2022 Edition Search #5592S22
Significant Changes to the California Energy Code, 2022 Edition Search #5523S22
2021 Code and Commentary The complete I-Code followed by corresponding commentary after each section
Each title includes the complete code text, including tables and figures, followed by in-depth insight after each code section. Gain a better understanding of the intent of the code and learn to apply or enforce it effectively.
2021 IBC Code and Commentary Search #3010S21
2021 IRC Code and Commentary Search #3110S21
2021 IFC Code and Commentary Search #3410S21
2021 IEBC Code and Commentary Search #3560S21
2021 I-Code Essentials A straightforward, focused approach to code fundamentals using non-code language
A user-friendly, concise approach that facilitates understanding of the essential code provisions. These invaluable companion guides contain detailed full-color illustrations to enhance comprehension, references to corresponding code sections, and a glossary of code and construction terms that clarify their meaning in the context of the code.
Building Code Essentials: Based on the 2021 IBC Search #4031S21
Residential Code Essentials: Based on the 2021 IRC Search #4131S21
Fire Code Essentials: Based on the 2021 IFC Search #4431S21
Existing Building Code Essentials: Based on the 2021 IEBC Search #4552S21
2021 I-Code Study Companions The ideal learning tool for exam prep or everyday application
These comprehensive study guides provide practical learning assignments helpful for independent study or instructor-led programs in the workplace, college courses, or vocational training programs. Each book is organized into study sessions with clear learning objectives, key points for review, code text and commentary applicable to the specific topic, and hundreds of illustrations. A helpful practice quiz at the end of each session allows you to measure your progress along the way.
2021 International Building Code Study Companion Search #4017S21
2021 International Residential Code Study Companion Search #4117S21
2021 International Fire Code Study Companion Search #4407S21
2021 Permit Technician Study Companion Search #4027S21
2021 Special Inspection Study Companion Search #4032S21
Browse the latest code tools at shop.iccsafe.org
22-21299
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
Copyright © 2022 by, or licensed to, International Code Council, Inc. (ALL RIGHTS RESERVED); licensed to California Building Standards Commission pursuant to License Agreement. No further reproductions is authorized. Any unauthorized reproduction or distribution is a violation of the federal copyright act and the license agreement, and subject to civil and criminal penalties thereunder.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Residential Code (Title 24, Part 2.5)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix AF — RADON CONTROL
- Appendix AI — PRIVATE SEWAGE
- Appendix AJ — EXISTING
- Appendix AK — SOUND
- Appendix AO — AUTOMATIC
- Appendix AR — LIGHT STRAW-CLAY
- Appendix AS — STRAWBALE
- Appendix AU — COB CONSTRUCTION
- Appendix AV — BOARD
- Appendix AW — 3D-PRINTED BUILDING
- Chapter 1 — SCOPE AND APPLICATION
- Chapter 3 — BUILDING PLANNING
- Chapter 4 — FOUNDATIONS
- Chapter 5 — FLOORS
- Chapter 6 — WALL CONSTRUCTION
- Chapter 7 — WALL COVERING
- Chapter 8 — ROOF-CEILING CONSTRUCTION
- Chapter 9 — ROOF ASSEMBLIES
- Chapter 10 — CHIMNEYS AND FIREPLACES
- Chapter 44 — REFERENCED STANDARDS
- Appendix AH — PATIO COVERS
- Appendix AL — PERMIT FEES
- Appendix AQ — TINY HOUSES
- Appendix AT — SOLAR-READY PROVISIONS—DETACHED ONE- AND
- Appendix AX — SWIMMING POOL SAFETY ACT
- Appendix AY — AREAS PROTECTED BY THE FACILITIES