Chapter 12-3 — RELEASING SYSTEMS FOR SECURITY BARS IN DWELLINGS
12-3-6 Secure Attachment Test — 2025 California Referenced Standards Code
California Referenced Standards Code (Title 24, Part 12) · 2025 edition · updated 2026-09-25 · California
Cite as: 2025 California Referenced Standards Code (Title 24, Part 12) § 12-3-6 · Effective January 1, 2026 · Official source: Building Standards Commission
12-3-6.1 Two samples of the system shall be subjected to the following test sequence.
12-3-6.2 The system, when in the closed position, shall resist 50-pound (22 N) force without opening, loosening in the test fixture or damaging the releasing assembly. The force shall be applied on the exterior side of the test fixture in a location that is most likely to move or damage the system. The force shall be gradually applied perpendicular to the opening and held for a period of 1 minute. A 3 / 8 -inch (10 mm) diameter rope looped through the security bars, or similar arrangement, shall be used to apply the force.
Get a plain-English answer with a citation back to this text.
Ask AI about this code