Chapter 12-3 — RELEASING SYSTEMS FOR SECURITY BARS IN DWELLINGS
Section 12-3-6 — SECURE ATTACHMENT TEST
2025 California Referenced Standards Code (Title 24, Part 12) · 2025 edition · updated 2026-07-29 · California
12-3-6.1 Two samples of the system shall be subjected to the following test sequence.
12-3-6.2 The system, when in the closed position, shall resist 50-pound (22 N) force without opening, loosening in the test fixture or damaging the releasing assembly. The force shall be applied on the exterior side of the test fixture in a location that is most likely to move or damage the system. The force shall be gradually applied perpendicular to the opening and held for a period of 1 minute. A 3 / 8 -inch (10 mm) diameter rope looped through the security bars, or similar arrangement, shall be used to apply the force.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Referenced Standards Code (Title 24, Part 12)
- Chapter 12-1 — ADMINISTRATION
-
▸ Chapter 12-3 — RELEASING SYSTEMS FOR SECURITY BARS IN DWELLINGS
Overview- Section 12-3-1 — SCOPE
- Section 12-3-2 — GENERAL
- Section 12-3-3 — ASSEMBLY
- Section 12-3-4 — MATERIALS
- Section 12-3-5 — TEST SETUP AND SAMPLE PREPARATION
- Section 12-3-6 — SECURE ATTACHMENT TEST
- Section 12-3-7 — OPERATION TEST
- Section 12-3-8 — MANUAL ACTUATION TEST
- Section 12-3-9 — ENDURANCE TEST
- Section 12-3-10 — ENVIRONMENTAL EXPOSURE TEST
- Section 12-3-11 — ABUSE TEST
- Section 12-3-12 — MARKINGS
- Section 12-3-13 — INSTRUCTION MANUAL
- Chapter 12-4A — LABORATORY ANIMAL QUARTERS STANDARDS
- Chapter 12-7A — MATERIALS AND CONSTRUCTION METHODS
- Chapter 12-11A and 11B — BUILDING AND FACILITY ACCESS SPECIFIC…
- Chapter 12-13 — STANDARDS FOR INSULATING MATERIAL
- Chapter 12-31C — RADIATION SHIELDING STANDARDS
- Chapter 12-71 — AIR FILTERS