Chapter 8-8 — ARCHAIC MATERIALS AND METHODS OF CONSTRUCTION

Section 8-812 — GLASS AND GLAZING

2025 California Historical Building Code (Title 24, Part 8) · 2025 edition · updated 2026-07-29 · California

8-812.1 Glazing subject to human impact. Historical glazing material located in areas subject to human impact may be approved subject to the concurrence of the enforcing agency when alternative protective measures are provided. These measures may include, but not be limited to, additional glazing panels, protective film, protective guards or systems, and devices or signs which would provide adequate public safety.

8-812.2 Glazing in fire-rated systems. See Section 8-402.3.

TABLE8-8A—STRENGTH VALUES FOR EXISTING MATERIALS

EXISTING MATERIALS OR CONFIGURATIONS OF MATERIALS1 STRENGTH LEVEL CAPACITY
x14.594 for N/m
1. Horizontal diaphragms2
1.1. Roofs with straight sheathing and roofing applied directly to the sheathing
1.2. Roofs with diagonal sheathing and roofing applied directly to the sheathing
1.3. Floors with straight tongue-and-groove sheathing
1.4. Floors with straight sheathing and finished wood flooring with board edges
offset or perpendicular
1.5. Floors with diagonal sheathing and finished
300 lbs per foot for seismic shear
750 lbs per foot for seismic shear
300 lbs per foot for seismic shear
1,500 lbs per foot for seismic shear
1,800 lbs per foot for seismic shear
2. Crosswalls2,3
2.1. Plaster on wood or metal lath
2.2. Plaster on gypsum lath
2.3. Gypsum wallboard, unblocked edges
2.4. Gypsum wallboard, blocked edges
Per side: 600 lbs per foot for seismic shear
550 lbs per foot for seismic shear
200 lbs per foot for seismic shear
400 lbs per foot for seismic shear
3. Existing footings, wood framing, structural steel and reinforcing steel
3.1. Plain concrete footings
3.2. Douglas fir wood
3.3. Reinforcing steel
3.4. Structural steel
fc = 1,500 psi (10.34 MPa) unless otherwise shown by
tests3
Allowable stress same as D.F. No. 13
_ft _= 40,000 lbs per square inch (124.1 N/mm2) maximum
ft= 33,000 lbs per square inch (137.9 N/mm2) maximum
1. Material must be sound and in good condition.
2. Shear values of these materials may be combined, except the total combined value shall not exceed 900 pounds per foot (13,140 N/m).
3. Stresses given may be increased for combinations of loads as specified in the regular code.

on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

ARCHAIC MATERIALS AND METHODS OF CONSTRUCTION

TABLE 8-8B—STRENGTH VALUES OF NEW MATERIALS USED IN CONNECTION WITH EXISTING CONSTRUCTION

NEW MATERIALS OR CONFIGURATIONS OF MATERIALS STRENGTH LEVEL CAPACITY1
1. Horizontal diaphragms2
1.1. 15/32 inch minimum plywood sheathing fastened directly over existing straight
sheathing with edges of plywood located on center of individual sheathing
boards and fastened with minimum #8x 11/4 inch wood screws or nails with
helical threads 0.13 inch min. diameter and 11/4 inch min. length at 4 inch
centers all panel edges and 12 inch centers each way in field
1.2. Same plywood and attachments as 1.1 fastened directly over existing diago-
nal sheathing
1.3. 3/8 inch plywood sheathing fastened directly over existing straight or diagonal
sheathing with ends and edges on centers of individual sheathing boards and
fastened with #6 wood screws or nails with helical threads 0.13 inch min.
diameter and 11/4 inch min. length at 6 inch centers tall panel edges and 12
inch centers each way in field
1,500 lbs per foot
1,800 lbs per foot
900 lbs per foot
2. Shear walls:
Plywood sheathing applied directly over wood studs. No value shall be given to
plywood applied over existing plaster or wood sheathing
100 percent of the value specified in the regular code for
shear walls
3. Crosswalls: (special procedure only)
3.1. Plywood sheathing applied directly over wood studs. No value shall be given
to plywood applied over existing plaster or wood sheathing
3.2. Drywall or plaster applied directly over wood studs
3.3. Drywall or plaster applied to sheathing over existing wood studs
133 percent of the value specified in the regular code for
shear walls
100 percent of the value specified in the regular code
50 percent of the value specified in the regular code
4. Tension bolts
a. Bolts extending entirely through unreinforced masonry walls secured with
bearing plates on far side of a three-wythe minimum wall with at least 30
square inches (19 350 mm2) of area4,5
b. All thread rod extending to the exterior face of the wall installed in adhesive9
5,400 lbs (24 010 N) per bolt6
2,700 lbs (12 009 N) per bolt for two-wythe walls6
3,600 lbs (16 014 N) per bolt
5. Shear bolts
Bolts embedded a minimum of 8 inches (203 mm) into unreinforced masonry
walls and centered in a 21/2-inch-diameter (63.5 mm) hole filled with dry-pack or
nonshrink grout. Through bolts with first 8 inches (203 mm) as noted above and
embedded all thread rod as noted in Item 4.b5,7,9
1/2 inch (12.7 mm) diameter = 1,050 lbs (4671 N)6
5/8 inch (15.9 mm) diameter = 1,500 lbs (6672 N)6
3/4 inch (19 mm) diameter = 2,250 lbs (10 008 N)6
6. Infilled walls
Reinforced masonry infilled openings in existing unreinforced masonry walls.
Provide keys or dowels to match reinforcing.
Same as values specified for unreinforced masonry walls
7. Reinforced masonry
Masonry piers and walls reinforced per the regular code
Same as values specified in the regular code8
8. Reinforced concrete
Concrete footings, walls and piers reinforced as specified in the regular code
and designed for tributary loads
Same as values specified in the regular code8
1. Values are for strength level loads as defined in regular code standards.
2. Values may be adjusted for other fasteners when approved by the enforcing authority.
3. In addition to existing sheathing value.
4. Bolts to be1/2-inch (12.7 mm) minimum diameter.
5. Other bolt sizes, values and installation methods may be used provided a testing program is conducted in accordance with regular code standards. Bolt spacing shall not
exceed 6 feet (1830 mm) on center and shall not be less than 12 inches (305 mm) on center.
6. Other masonry based on tests or other substantiated data.
7. Embedded bolts to be tested as specified in regular code standards.
8. Stresses given may be increased for combinations of loads as specified in the regular code.
9. Adhesives shall be approved by the enforcing agency and installed in accordance with the manufacturer’s recommendations. All drilling dust shall be removed from drilled
holes prior to installation.