8-807.1 Existing wood diaphragms or walls. Existing wood diaphragms or walls of straight or diagonal sheathing shall be assigned shear resistance values appropriate with the fasteners and materials functioning in conjunction with the sheathing. The structural survey shall determine fastener details and spacings and verify a load path through floor construction. Shear values of Tables 8-8-A and 8-8-B.
8-807.2 Wood lath and plaster. Wood lath and plaster walls and ceilings may be utilized using the shear values referenced in Section 8-807.1.
8-807.3 Existing wood framing. Existing wood framing members may be assigned allowable stresses consistent with codes in effect at the time of construction. Existing or new replacement wood framing may be of archaic types originally used if properly researched, such as balloon and single wall. Wood joints such as dovetail and mortise and tenon types may be used structurally, provided they are well made. Lumber selected for use and type need not bear grade marks, and greater or lesser species such as low-level pine and fir, boxwood and indigenous hardwoods and other variations may be used for specific conditions where they were or would have been used.
Wood fasteners such as square or cut nails may be used with a maximum increase of 50 percent over wire nails for shear.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — 2025 California Historical Building Code (Title 24, Part 8)
- Chapter 8-1 — ADMINISTRATION
- Chapter 8-2 — DEFINITIONS
- Chapter 8-3 — USE AND OCCUPANCY
- Chapter 8-4 — FIRE PROTECTION
- Chapter 8-5 — MEANS OF EGRESS
- Chapter 8-6 — ACCESSIBILITY
- Chapter 8-7 — STRUCTURAL REGULATIONS
-
▸ Chapter 8-8 — ARCHAIC MATERIALS AND METHODS OF CONSTRUCTION
Overview- Section 8-801 — PURPOSE, INTENT AND SCOPE
- Section 8-802 — GENERAL ENGINEERING APPROACHES
- Section 8-803 — NONSTRUCTURAL ARCHAIC MATERIALS
- Section 8-804 — ALLOWABLE CONDITIONS FOR SPECIFIC MATERIALS
- Section 8-805 — MASONRY
- Section 8-806 — ADOBE
- Section 8-807 — WOOD
- Section 8-808 — CONCRETE
- Section 8-809 — STEEL AND IRON
- Section 8-810 — HOLLOW CLAY TILE
- Section 8-811 — VENEERS
- Section 8-812 — GLASS AND GLAZING
- Chapter 8-9 — MECHANICAL, PLUMBING AND ELECTRICAL REQUIREMENTS
- Chapter 8-10 — QUALIFIED HISTORICAL DISTRICTS, SITES AND OPEN …