Skip to content

Chapter 8-8 — ARCHAIC MATERIALS AND METHODS OF CONSTRUCTION

Section 8-809 — STEEL AND IRON

2025 California Historical Building Code (Title 24, Part 8) · 2025 edition · updated 2026-07-29 · California

The hand-built, untested use of wrought or black iron, the use of cast iron or grey iron, and the myriad of joining methods that are not specifically allowed by code may be used wherever applicable and wherever they have proven their worth under the considerable span of years involved with most qualified historical buildings or structures. Uplift capacity should be evaluated and strengthened where necessary. Fixed conditions or midheight lateral loads on cast iron columns that could cause failure should be taken into account. Existing structural wrought, forged steel or grey iron may be assigned the maximum working stress prevalent at the time of original construction.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — 2025 California Historical Building Code (Title 24, Part 8)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.