California Green Building Standards Code (Title 24, Part 11) · 2019 edition · updated 2026-09-12 · California

RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued

FEATURE OR MEASURE LEVELS
APPLICANT TO SELECT ELECTIVE MEASURES
VERIFICATIONS
ENFORCING AGENCY TO SPECIFY
VERIFICATION METHOD
FEATURE OR MEASURE Mandatory Prerequisites and electives1 Prerequisites and electives1 Enforcing
Agency

All
Installer or
Designer

All
Third
party

All
FEATURE OR MEASURE Mandatory Tier 1 Tier 2 Tier 2 Tier 2 Tier 2
4.504.3Carpet and carpet systems shall be compliant with VOC
limits.
4.504.480 percent of floor area receiving resilient flooring shall
comply with specified VOC criteria.
4.504.5Particleboard, medium density fiberboard (MDF) and
hardwood plywood used in interior finish systems shall comply with
low formaldehyde emission standards.
A4.504.1Use composite wood products made with either California
Air Resources Board approved no-added formaldehyde (NAF) resins
or ultra-low emitting formaldehyde (ULEF) resins.
A4.504.2Install VOC compliant resilient flooring systems.
Tier 1. At least 90 percent of the resilient flooring installed shall
comply.
**Tier 2.**At least 100 percent of the resilient flooring installed shall
comply.
2 2
A4.504.3Thermal insulation installed in the building shall meet the
following requirements:
Tier 1. Install thermal insulation in compliance with VOC limits.
Tier 2. Install insulation which contains No-Added Formaldehyde
(NAF) and is in compliance with Tier 1.
2 2
Interior Moisture Control
4.505.2Vapor retarder and capillary break is installed at slab-on-
grade foundations.
4.505.3 Moisture content of building materials used in wall and floor
framing is checked before enclosure.
Indoor Air Quality and Exhaust
4.506.1 Each bathroom shall be provided with the following:
1. ENERGY STAR fans ducted to terminate outside the building.
2. Fans must be controlled by a humidity control (separate or built-
in); OR functioning as a component of a whole-house ventilation
system.
3. Humidity controls with manual or automatic means of
adjustment, capable of adjustment between a relative humidity
range of≤ 50 percent to a maximum of 80 percent.
A4.506.1 Reserved.
A4.506.2 [HR] Provide filters on return air openings rated MERV 8
or higher during construction when it is necessary to use HVAC
equipment.
A4.506.3 Direct-vent appliances shall be used when equipment is
located in conditioned space; or the equipment must be installed in an
isolated mechanical room.

continued

Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.

100735044

RESIDENTIAL VOLUNTARY MEASURES

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — California Green Building Standards Code (Title 24, Part 11)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.