Section A4.602

California Green Building Standards Code (Title 24, Part 11) · 2019 edition · updated 2026-09-12 · California

RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued

FEATURE OR MEASURE LEVELS
APPLICANT TO SELECT ELECTIVE MEASURES
VERIFICATIONS
ENFORCING AGENCY TO SPECIFY
VERIFICATION METHOD
FEATURE OR MEASURE Mandatory Prerequisites and electives1 Prerequisites and electives1 Enforcing
Agency

All
Installer or
Designer

All
Third
party

All
FEATURE OR MEASURE Mandatory Tier 1 Tier 2 Tier 2 Tier 2 Tier 2
A4.106.2.1Soil analysis is performed by a licensed design
professional and the findings utilized in the structural design of the
building.
A4.106.2.2Soil disturbance and erosion are minimized by at least
one of the following:
1. Natural drainage patterns are evaluated and erosion controls are
implemented to minimize erosion during construction and after
occupancy.
2. Site access is accomplished by minimizing the amount of cut and
fill needed to install access roads and driveways.
3. Underground construction activities are coordinated to utilize the
same trench, minimize the amount of time the disturbed soil is
exposed and the soil is replaced using accepted compaction
methods.










A4.106.2.3 Topsoil shall be protected or saved for reuse as specified
in this section.
**Tier 1.**Displaced topsoil shall be stockpiled for reuse in a
designated area and covered or protected from erosion.
**Tier 2.**The construction area shall be identified and delineated by
fencing or flagging to limit construction activity to the construction
area.
2 2
2
A4.106.3Postconstruction landscape designs accomplish one or
more of the following:
1. Areas disrupted during construction are restored to be consistent
with native vegetation species and patterns.
2. Utilize at least 75 percent native California or drought tolerant
plant and tree species appropriate for the climate zone region.





A4.106.4Permeable paving is utilized for the parking, walking or
patio surfaces in compliance with the following:
Tier 1. Not less than 20 percent of the total parking, walking or
patio surfaces shall be permeable.
Tier 2. Not less than 30 percent of the total parking, walking or
patio surfaces shall be permeable.
2 2


A4.106.5Roofing materials shall have a minimum 3-year aged solar
reflectance and thermal emittance or a minimum Solar Reflectance
Index (SRI) equal to or greater than the values specified in the
applicable tables.
Low-rise Residential
Tier 1 roof covering shall meet or exceed the values contained in
Table A4.106.5.1(1).
Tier 2 roof covering shall meet or exceed the values contained in
Table A4.106.5.1(2).
High-rise Residential, Hotels and Motels
Tier 1 roof covering shall meet or exceed the values contained in
Table A4.106.5.1(3).
Tier 2 roof covering shall meet or exceed the values contained in
Table A4.106.5.1(4).
2
2
2
2









continued

116 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE

Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.