Chapter 32 — HIGH-PILED COMBUSTIBLE STORAGE

Section 3205

California Fire Code (Title 24, Part 9) · 2022 edition · updated 2026-09-10 · California

CBSC: official editions, supplements and errata

Italicized text is a California amendment to the model code, as printed in the official publication.

3205.1 Storage layout plan maintenance. The approved

storage layout shall be verified and evaluated annually in accordance with Section 3201.3.2. Modifications or changes to the provisions of the approved storage layout shall not be made without the prior approval of the fire code official.

Exceptions & meaning →

3205.2 Rack structures. The structural integrity of racks

shall be maintained.

Exceptions & meaning →

3205.3 Ignition sources. Clearance from ignition sources

shall be provided in accordance with Section 305.

Exceptions & meaning →

3205.4 Smoking. Smoking shall be prohibited. Approved

“No Smoking” signs shall be conspicuously posted in accordance with Section 310.

Exceptions & meaning →

3205.5 Aisle maintenance. When restocking is not being

conducted, aisles shall be kept clear of storage, waste material and debris. Fire department access doors, aisles and exit doors shall not be obstructed. During restocking operations using manual stocking methods, a minimum unobstructed aisle width of 24 inches (610 mm) shall be maintained in 48-inch (1219 mm) or smaller aisles, and a minimum unobstructed aisle width of one-half of the required aisle width shall be maintained in aisles greater than 48 inches (1219 mm). During mechanical stocking operations, a minimum unobstructed aisle width of 44 inches (1118 mm) shall be maintained in accordance with Section 3206.10.

Exception: In high-piled single- and double-row rack storage of combustible materials protected by automatic sprinkler systems designed and installed in accordance with the requirements of NFPA 13 governing the use of K25.2 (360) sprinklers, displays and wing stacks not exceeding 48 inches (1219 mm) in height provided that they do not obstruct or reduce the clear width of the aisle to less than 48 inches (1219 mm).

Exceptions & meaning →

3205.6 Pile dimension and height limitations.

Pile dimensions and height limitations shall comply with Section 3207.3.

Exceptions & meaning →

3205.7 Designation of storage heights. Where required by

the fire code official, a visual method of indicating the maximum allowable storage height shall be provided.

Exceptions & meaning →

3205.8 Arrays. Arrays shall comply with Section 3207.4.

Exceptions & meaning →

3205.9 Flue spaces. Flue spaces shall comply with Section

3208.3.

Exceptions & meaning →