ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D107.1 One- or two-family dwelling residential develop-¶
ments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads.
Exceptions:
- Where there are more than 30 dwelling units accessed from a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1,
APPENDIX D—FIRE APPARATUS ACCESS ROADS
903.3.1.2 or 903.3.1.3, access from two directions shall not be required. 2. The number of dwelling units accessed from a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official.
D107.2 Remoteness. Where two fire apparatus access roads¶
are required, they shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the property or area to be served, measured in a straight line between accesses.