Chapter 29 — MANUFACTURE OF ORGANIC COATINGS
2908 Raw Materials in Process Areas — 2025 California Fire Code
California Fire Code (Title 24, Part 9) · 2025 edition · updated 2026-09-25 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Fire Code (Title 24, Part 9) § 2908 · Effective January 1, 2026 · Official source: Building Standards Commission
2908.1 Nitrocellulose quantity.¶
The amount of nitrocellulose brought into the operating area shall not exceed the amount required for a work shift. Nitrocellulose spillage shall be promptly swept up and disposed of properly.
2908.2 Organic peroxides quantity.¶
Organic peroxides brought into the operating area shall be in the original shipping container. When in the operating area, the organic peroxide shall not be placed in locations exposed to ignition sources, heat or mechanical shocks.