DEFINITIONS
ANCILLARY FACILITY is any area used in conjunction with or for the operation of a pool such as public dressing rooms, lockers, shower or bathroom areas, drinking foun- tains, equipment room, pool deck area, pool enclosure or building space that is intended to be used by pool users.
BACKWASH is the process of reversing the flow of water through the filter to thoroughly clean the filter media and/or elements and remove the debris from the contents of the filter vessel.
CANTILEVERED DECKING is the part of the deck which extends over a top edge of a pool or spa.
CLEAN POOL WATER is pool water that is free of dirt, oils, scum, algae, floating materials or visible organic and inorganic materials that would pollute the water.
CLEAR POOL WATER is pool water that is free from cloudiness and is transparent.
COPING is a slip-resistant cap installed on the top edge of a pool or spa.
CORROSION RESISTANT is capable of maintaining origi- nal surface characteristics under the prolonged influence of the use environment.
DECK is an area surrounding a pool which is specifically constructed or installed for use by pool users.
EFFECTIVE PARTICLE SIZE is the theoretical size of a sieve in mm that will pass 10 percent by weight of sand.
ENFORCING AGENT is the health officer, director of envi- ronmental health, registered environmental health specialist or environmental health specialist trainee.
EQUIPMENT AREA is an area where the recirculation sys- tem and all related appurtenances are located.
HANDHOLD is a structure located at or above the water line around the perimeter of the pool wall that allows a pool user to hold onto the poolside for support.
INLET is a fitting or fixture through which recirculated water enters the pool.
LADDER is a series of vertically separate treads or rungs either connected by vertical rail members or independently fastened to an adjacent vertical pool wall.
LIVING UNIT is any building or portion thereof that con- tains living facilities including provisions for sleeping.
MAIN DRAIN is a submerged suction outlet typically located at the bottom of a pool that conducts water to a recir- culating pump.
MEDICAL POOL is a special-purpose pool used by a State- recognized medical institution engaged in the healing arts under the direct supervision of licensed medical personnel for treatment of the infirm.
OUTLET is a fitting or fixture through which recirculated water is removed from the pool which may or may not be con- nected to the pump.
PERFORMANCE STANDARD is a standard that is accred- ited and published. Products compliant with a standard may be listed by any authorized nationally recognized testing lab- oratory.
PERIMETER OVERFLOW SYSTEM is a system which includes perimeter-type overflow gutters, surge basin or sim- ilar surface water collective system components and their interconnecting piping.
PERMISSIBLE EXPOSURE LIMIT is the maximum amount or concentration of a chemical that a worker may be exposed to under United States Occupational Safety and Health Administration regulations.
POOL OR PUBLIC POOL is an artificial basin, chamber or tank constructed or prefabricated with impermeable surfaces that is used, or intended to be used, for public swimming, div- ing or recreational activities but does not include individual therapeutic tubs or baths where the main purpose is the
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
PUBLIC POOLS
cleaning of the body. Any manmade lake or swimming lagoon with a sand beach or sand bottom is not a public pool.
POOL OPERATOR or OPERATOR is a person who is responsible for maintaining compliance with all require- ments relating to pool operation, maintenance and safety of pool users.
POOL USER is a person using a pool and ancillary facilities for the purpose of water activities such as diving, swimming or wading.
RADIUS OF CURVATURE is the radius arc which denotes the curved surface from the point of departure from the springline of the pool to the pool bottom.
READILY ACCESSIBLE is capable of being reached easily for cleaning, repair, replacement or inspection without the necessity of removing a panel, door or similar obstruction and without requiring a person to climb over or remove obstacles or to use devices such as portable ladders.
READILY DISASSEMBLED means capable of being taken apart by hand or by using only simple tools such as a screw- driver, pliers or open-end wrench.
RECESSED STEPS are a series of vertically spaced cavities in the pool wall creating riser and tread areas for pool ingress and egress.
RECIRCULATION SYSTEM is the system of hydraulic components designed to remove, filter, disinfect and return water to the pool.
RIM FLOW GUTTER is a perimeter overflow system in which the overflow rim is at the same elevation with the deck.
SKIMMER EQUALIZER LINE is a submerged suction out- let located below the waterline and connected to the body of a skimmer that prevents air from being drawn into the pump if the water level drops below the skimmer weir or the skimmer is blocked by debris. A skimmer equalizer line is not a main drain.
SLIP RESISTANT is a rough finish that is not abrasive to the bare foot.
SPA POOL OR SPA is a pool that incorporates a water jet system, an aeration system or a combination of the two sys- tems used in conjunction with heated water.
SPECIAL PURPOSE POOL is a pool constructed exclu- sively for a specific purpose, such as instruction, diving, com- petition or medical treatment.
SPLASH ZONE is the maximum distance the water from a spray ground can project horizontally.
SPRAY GROUND is a pool with no standing water in the splash zone and consists of a surge basin with a recirculation system from which water is directed through water features for contact with pool users.
SPRINGLINE is the point from which the pool wall breaks from vertical and begins its arc in the radius of curvature.
STAIRS are a series of two or more steps.
STEP is a riser and tread.
SUCTION OUTLET is any outlet that is connected to the pump through which water is removed from the pool.
SURGE BASIN is a reservoir or surge trench open to the atmosphere that receives water via gravity flow from the main drain, spray ground or perimeter overflow system and from which the recirculation system operates.
TEMPERED WATER is water between 100°F and 110°F.
TURNOVER TIME is the maximum time allowed to circu- late one complete volume of the pool water through the recir- culation system.
UNIFORMITY COEFFICIENT is the ratio of the theoreti- cal size of a sieve in mm that will pass 60 percent of the sand to the theoretical size of a sieve in mm that will pass 10 per- cent of the sand.
WADING POOL is a pool intended to be used for wading by small children and having a maximum water depth of 18 inches (457 mm) at the deepest point.
WATER FEATURE means an interactive device or struc- ture through which water is directed to the pool user such as a water fountain, water spray, dancing water jet, waterfall, dumping bucket or shooting water cannon.
WATERLINE shall be defined as one of the following:
1. Skimmer system. The waterline shall be the midpoint of the operating range of the skimmers.
2. Overflow system. The waterline shall be the top edge of the overflow rim.
PLAN REVIEW, PERMITS, CONSTRUCTION AND FIELD INSPECTIONS
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Building Code (Title 24, Part 2)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix G — FLOOD-RESISTANT
- Appendix L — EARTHQUAKE RECORDING
- Appendix M — TSUNAMI-GENERATED
- Chapter 1 — SCOPE AND ADMINISTRATION
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11A — HOUSING ACCESSIBILITY
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
- Chapter 12 — INTERIOR ENVIRONMENT
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 22 — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
▸Chapter 31B — PUBLIC POOLS
Overview- Section 3101B
- Section 3102B
- Section 3103B
- Section 3104B
- Section 3105B
- Section 3106B
- Section 3107B
- Section 3108B
- Section 3109B
- Section 3110B
- Section 3111B
- Section 3112B
- Section 3113B
- Section 3114B
- Section 3115B
- Section 3116B
- Section 3117B
- Section 3118B
- Section 3119B
- Section 3120B
- Section 3121B
- Section 3122B
- Section 3123B
- Section 3124B
- Section 3125B
- Section 3126B
- Section 3127B
- Section 3128B
- Section 3129B
- Section 3130B
- Section 3131B
- Section 3132B
- Section 3133B
- Section 3134B
- Section 3135B
- Section 3136B
- Section 3137B
- Section 3138B
- Section 3139B
- Section 3140B
- Section 3141B
- Section 3142B
- Section 3143B
- Section 3144B
- Section 3145B
- Section 3146B
- Section 3147B
- Section 3148B
- Section 3149B
- Section 3150B
- Section 3151B
- Section 3152B
- Section 3153B
- Section 3154B
- Section 3155B
- Section 3156B
- Section 3157B
- Section 3158B
- Section 3159B
- Section 3160B
- Section 3161B
- Section 3162B
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U – AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix F — RODENTPROOFING
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — EMERGENCY HOUSING