Chapter 12 — INTERIOR ENVIRONMENT
Section 1231 — [BSCC]
California Building Code (Title 24, Part 2) · 2019 edition · updated 2026-09-12 · California
Italicized text is a California amendment to the model code, as printed in the official publication.
1231.1 Definitions.¶
BOARD OF STATE & COMMUNITY CORRECTIONS means the Board of State & Community Corrections, which acts by and through its executive officer, deputy directors and field representatives.
LIVING AREAS means those areas of a facility utilized for the day-to-day housing and activities of inmates. These areas do not include special-use cells such as sobering, safety and holding or staging cells normally located in receiving areas.
LOCAL DETENTION FACILITY is any city, county, city and county, or regional jail, camp, court holding facility or other correctional facility, whether publicly or privately operated, and court holding facility used for the confine- ment of adults or of both adults and minors, but does not include that portion of a facility for the confinement of both adults and minors which is devoted only to the confinement of minors. The types of local detention facilities are as fol- lows:
Court holding facility means a local detention facility constructed within a court building after January 1, 1978, used for the confinement of persons solely for the purpose of a court appearance for a period not to exceed 12 hours.
Temporary holding facility means a local detention facil- ity constructed after January 1, 1978, used for the confine- ment of persons for 24 hours or less pending release, transfer to another facility or appearance in court.
Type I facility means a local detention facility used for the detention of persons usually pending arraignment for not more than 96 hours, excluding holidays, after book- ing. Such a Type I facility may also detain persons on court order either for their own safe-keeping or sen- tenced to a city jail as an inmate worker, and may house
INTERIOR ENVIRONMENT
inmate workers sentenced to the county jail provided such placement in the facility is made on a voluntary basis on the part of the inmate. As used in this section, an inmate worker is defined as a person assigned to perform designated tasks outside of his or her cell or dormitory, pursuant to the written policy of the facility, for a mini- mum of four hours each day on a five-day scheduled work week.
TYPE II FACILITY means a local detention facility used for the detention of persons pending arraignment, after arraign- ment, during trial and upon a sentence of commitment.
TYPE III FACILITY means a local detention facility used only for the detention of convicted and sentenced persons.
TYPE IV FACILITY means a local detention facility or por- tion thereof designated for the housing of inmates eligible, under Penal Code Section 1208, for work/education furlough and/or other programs involving inmate access into the com- munity.
RATED CAPACITY means the number of inmate occupants for which a facility’s single-and double-occupancy cells or dormitories, except those dedicated for medical or disci- plinary isolation housing, were planned and designed in con- formity to the standards and requirements contained herein and in Title 15, C.C.R.
1231.2 Design criteria for required spaces.¶
1231.2.1 Reception and booking. Facilities where book- ing and housing occur shall have the following space and equipment:
1. Weapons locker as specified in Section 1231.3.12.
2. A cell or room for the confinement of inmates pend- ing their booking, complying with Section 1231.2.2.
3. A sobering cell as described in Section 1231.2.4 if intoxicated, inmates who may pose a danger to themselves or others are held. For those facilities that accept male and female intoxicated inmates two sobering cells shall be provided.
4. Access to a shower within the secure portion of the facility.
5. Provide access to a secure vault or storage space for inmate valuables.
6. A safety cell or cells as described in Section 1231.2.5 if the program statement identifies the need for such a cell.
7. Telephones which are accessible to the inmates.
8. Unobstructed access to hot and cold running water for staff use.
1231.2.2 Temporary holding cell or room. A temporary holding cell or room shall:
1. Contain a minimum of 10 square feet (0.93 m 2 ) of floor area per inmate;
2. Be limited to no more than 16 inmates;
3. Be no smaller than 40 square feet (3.7 m 2 ) and have a clear ceiling height of 8 feet (2438 mm) or more;
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
INTERIOR ENVIRONMENT
4. Contain seating to accommodate all inmates as required in Section 1231.3;
5. Contain a toilet, wash basin and drinking fountain as specified in Section 1231.3;
6. Maximize visual supervision of inmates by staff; and
7. When located in a temporary holding facility, the cell or room shall be equipped with a bunk if inmates are to be held longer than 12 hours.
1231.2.3 Temporary staging cell or room. A temporary staging cell or room shall:
1. Be constructed for the purpose of holding inmates who have been classified and segregated in accor- dance with Sections 1050 and 1053 of Title 15, Divi- sion 1, California Code of Regulations.
2. Be limited to holding inmates up to four hours.
3. Be limited to no more than 80 inmates.
4. Contain a minimum of 10 square feet (0.93 m 2 ) of floor area per inmate and a clear ceiling height of 8 feet (2438 mm) or more.
5. Be no smaller than 160 square feet (14.9 m 2 ).
6. Contain seating to accommodate all inmates as required in Section 1231.3.
7. Contain toilet, wash basin and drinking fountain as specified in Section 1231.3.
8. Maximize visual supervision of inmates by staff.
1231.2.4 Sobering cell. A sobering cell shall:
1. Contain a minimum of 20 square feet (1.9 m 2 ) of floor area per inmate;
2. Be limited to eight inmates;
3. Be no smaller than 60 square feet (5.6 m 2 ) and have a clear ceiling height of 8 feet (2438 mm) or more;
4. Contain a toilet, wash basin and drinking fountain as specified in Section 1231.3;
5. Have padded partitions located next to toilet fixture in such a manner that they provide support to the user;
6. Maximize visual supervision of inmates by staff;
7. Be padded on the floor as specified in Section 1231.3; and,
8. Have accessible a shower in the secure portion of the facility.
1231.2.5 Safety cell. A safety cell shall:
1. Contain a minimum of 48 square feet (4.5 m 2 ) of floor area with no one floor dimension being less than 6 feet (1829 mm) and a clear ceiling height of 8 feet (2438 mm) or more;
2. Be limited to one inmate;
3. Contain a flushing ring toilet, capable of accepting solid waste, mounted flush with the floor, the con- trols for which must be located outside of the cell;
4. Be padded as specified in Section 1231.3;
5. Be equipped with a variable intensity, security-type lighting fixture which is inaccessible to the inmate
occupant, control of which is located outside of the cell;
6. Provide one or more vertical view panels not more than 4 inches (102 mm) wide nor less than 24 inches (610 mm) long which shall provide a view of the entire room;
7. Provide a food pass with lockable shutter, no more than 4 inches (102 mm) high, and located between 26 inches (660 mm) and 32 inches (813 mm) as mea- sured from the bottom of the food pass to the floor; and,
8. Any wall or ceiling mounted devices must be inac- cessible to the inmate occupant.
1231.2.6 Single-occupancy cells. Single-occupancy cells shall:
1. Have a maximum capacity of one inmate;
2. Contain a minimum of 60 square feet (5.6 m 2 ) of floor area in Type I facilities and 70 square feet (6.5 m 2 ) of floor area in Type II and Type III facilities;
3. Have a minimum clear ceiling height of 8 feet (2438 mm) and a minimum width of 6 feet (1829 mm);
4. Contain a toilet, wash basin and drinking fountain as specified in Section 1231.3; and
5. Contain a bunk, desk and seat as specified in Section 1231.3.
Exception: A Type I facility does not require a desk and seat.
1231.2.7 Double-occupancy cells. Double-occupancy cells shall:
1. Have a maximum capacity of two inmates;
2. Contain a minimum of 60 square feet (5.6 m 2 ) of floor area in Type I facilities and 70 square feet (6.5 m 2 ) of floor area in Type II and Type III facilities;
3. Have a minimum clear ceiling height of 8 feet (2438 mm) and a minimum width of 6 feet (1829 mm);
4. Contain a toilet, wash basin and drinking fountain as specified in Section 1231.3; and
5. Contain two bunks, and at least one desk and seat as specified in Section 1231.3.
Exception: A Type I facility does not require a desk and seat.
1231.2.8 Dormitories. Dormitories shall:
1. Contain a minimum of 50 square feet (4.7 m 2 ) of floor area per inmate for a single-bed unit; a mini- mum of 70 square feet (7 m 2 ) for a double-bed unit; and a minimum of 90 square feet (9.3 m 2 ) for triple- bed unit and have a minimum ceiling height of 8 feet (2438 mm);
2. Be designed for no more than 64 inmates and no fewer than four inmates;
3. Provide access to water closets separate from the wash basin and drinking fountains as specified in Section 1231.3; and
738 2019 CALIFORNIA BUILDING CODE
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
4. In other than Type I facilities, provide storage space for personal items and clothing for each occupant.
1231.2.9 Dayrooms.
Dayrooms or dayroom space shall:
1. Contain 35 square feet (3.3 m 2 ) of floor area per inmate in width in front of cells/rooms;
2. Contain tables and seating to accommodate the maximum number of inmates;
3. Provide access to water closets, wash basins and drinking fountains as specified in Section 1231.3;
4. Provide access to a shower or showers as specified in Section 1231.3; and
5. Be provided to all inmates in Type II and Type III facilities (except those housed in special-use cells) and to inmate workers in Type I facilities.
Dayroom space as described in this section may be a part of a single occupancy cell used for administrative segregation or a dormitory, in which case the floor area of the cell or a dormitory must be increased by the square footage required for the dayroom.
1231.2.10 Exercise area. An outdoor exercise area or areas must be provided in every Type II and Type III facil- ity. The minimum clear height must be 15 feet (4572 mm) and the minimum number of square feet of surface area will be computed by multiplying 80 percent of maximum rated population by 50 square feet (4.7 m 2 ) and dividing the result by the number of one-hour exercise periods per day.
The exercise area must contain or provide free access to a toilet, wash basin, and drinking fountain as provided in Section 1231.3.
There must be at least one exercise area of not less than 600 square feet (55.7 m 2 ). The design shall facilitate secu- rity and supervision appropriate to the level of custody.
Type IV facilities shall have an outdoor recreation area or access to community recreation facilities.
1231.2.11 Correctional program/multipurpose space. An area for correctional programming must be provided in every Type II and Type III facility. The program area and furnishings shall be designed to meet the needs specified by the facility’s program statement.
Type IV facilities shall have multipurpose space for games and activities, dining, visiting, TV meetings and quiet space for study and reading, such that activities do not conflict with each other.
1231.2.12 Medical examination room. There must be a minimum of one suitably equipped medical examination room in every facility which provides on-site health care. The examination room shall be designed in consultation with the responsible physician/health authority. Such a medical examination room shall:
1. Be located within the security area and provide for privacy of the inmates;
INTERIOR ENVIRONMENT
2. Provide not less than 100 square feet (9.3 m 2 ) of floor space with no single dimension less than 7 feet (2134 mm);
3. Provide hot and cold running water;
4. Provide lockable storage for medical supplies;
5. Provide an examination table;
6. Provide adequate lighting; and
7. Any room where medical procedures are provided must be equipped with hot and cold running water
1231.2.13 Pharmaceutical storage space. Provide lock- able storage space for medical supplies and pharmaceuti- cal preparations as referenced by Title 15, California Code of Regulations, Section 1216.
1231.2.14 Medical care housing. There shall be some means to provide medical care and housing of ill and/or infirm inmates. When the program statement for a Type II or Type III facility indicates that medical care housing is needed, such housing must provide lockable storage space for medical instruments and must be located within the security area of the facility accessible to both female and male inmates, but not in the living area of either. The medical care housing unit shall be designed in consulta- tion with the health authority. Medical/mental health areas may contain other than single occupancy cells.
If negative pressure isolation rooms are being planned, they shall be designed to recognized industry standards.
1231.2.15 Reserved.
1231.2.16 Commissary. In all Type II, III and IV facilities, except where community access is available, there shall be provisions made for inmates to purchase items (such as candy, toilet articles, stationery supplies, books, newspa- pers and magazines, etc.). An area shall be provided for the secure storage of the stock for such inmate canteen items.
1231.2.17 Dining facilities. In all Type II, III and IV facil- ities which serve meals, dining areas shall be provided which will allow groups of inmates to dine together. Such dining areas shall not contain toilets, wash basins or showers in the same room without appropriate visual bar- rier. Wherever the facility contains a central dining room or rooms, it shall contain a minimum of 15 square feet (1.4 m 2 ) of floor space and sufficient tables and seating for each inmate being fed.
1231.2.18 Visiting space. Space shall be provided in all Types I, II, III and IV facilities for in-person visiting.
1231.2.19 Safety equipment storage. A secure area shall be provided for the storage of safety equipment such as fire extinguishers, self-contained breathing apparatus, wire and barcutters, emergency lights, etc.
1231.2.20 Janitors’ closet. In Type II facilities, at least one securely lockable janitors’ closet with sufficient area for the storage of cleaning implements and supplies must be pro- vided within the security areas of the facility. A mop sink shall also be available within the security area of the facil- ity. In court holding, temporary holding, Types I, III and IV facilities, the closet need not be in the security area.
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
INTERIOR ENVIRONMENT
TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
| TYPE I | TYPE II | TYPE III | TYPE IV | COURT HOLDING |
TEMPORARY HOLDING |
|
|---|---|---|---|---|---|---|
| Reception/booking | x | x | * | * | * | |
| Temporary holding cells or room | x | x | * | * | x | x |
| Detoxification cell | * | x | ||||
| Safety cell | * | * | ||||
| Single-occupancy cell | x | x | * | |||
| Dormitories | * | x | x | x | ||
| Day room | * | x | x | |||
| Exercise area | x | x | x1 | |||
| Shower area/delousing room | x | x | * | |||
| Program/multipurpose space | x | x | x | |||
| Medical exam room2 | x | x | ||||
| Pharmaceutical storage space | x | x | x | x | * | |
| Medical care housing | * | * | ||||
| Hair care space | x | x | ||||
| Commissary3 | x | x3 | ||||
| Dining facility4 | * | x | x | * | ||
| Visiting space | x | x | x | x | ||
| Attorney interview rooms | x | x | x | x | x | |
| Confidential interview rooms | x | * | ||||
| Safety equipment storage | x | x2 | x | x | x | x |
| Janitor closet | x | x | x | x | x | x |
| Storage rooms | x | x5 | x | x | x | x |
| Audio/video-monitoring systems | x | x | x6 | * | x | x |
| Laundry facility | x | x7 | ||||
| Fire-detection alarm system | x | x | x | x | x | x |
| Emergency | x | x | x | x | x | x |
x - Required.
* - Required when program statement identifies need. 1. Not required if community recreation facilities are available. 2. Not required if the inmate population is less than 25. 3. Not required if community access is available. 4. Not required if meals are served in day room. 5. Must be securely lockable and located within the security area. 6. Required in areas housing prisoners of higher than minimum security. 7. Not required if community access is permitted.
1231.2.21 Storage rooms. One or more storage rooms shall be provided to accommodate a minimum of 80 cubic feet (2.3 m 3 ) of storage area per inmate for inmate cloth- ing and personal property, institutional clothing, bedding and supplies. Court holding, temporary holding and Type I facilities may be excluded from the storage space requirement for personal and institutional clothing unless clothing is issued.
1231.2.22 Audio monitoring system. In court holding, temporary holding, Type I, Type II and Type II facilities there shall be an inmate- or sound-actuated audio moni- toring system in temporary holding cells or rooms, tempo- rary staging cells or rooms, sobering cells, safety cells, single and double occupancy cells, dormitories, day-
rooms, exercise areas and correctional program/multipur- pose space, which is capable of alerting personnel who can respond immediately.
1231.2.23 Laundry facilities. In Type IV facilities, provi- sion shall be made for washing and drying personal cloth- ing by machines, either in the facility or in the community, if access is permitted for same.
1231.2.24 Emergency power. There shall be a source of emergency power in all detention facilities capable of pro- viding minimal lighting in all housing units, activities areas, corridors, stairs and central control points, and to maintain fire and life safety, security, communications and alarm systems. Such an emergency power source shall conform to the requirements specified in Title 24, Part 3,
740 2019 CALIFORNIA BUILDING CODE
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
Article 700, California Electrical Code, California Code of Regulations.
1231.2.25 Confidential interview rooms. There must be a minimum of one suitably furnished interview room for confidential interviews in every facility which provides on- site health care. The interview room shall be designed in consultation with responsible custodial staff and health care staff. Such an interview room shall:
1. Be located within the security area accessible to both female and male inmates; and
2. Provide not less than 70 square feet (6.5 m 2 ) of floor space with no single dimension less than 6 feet (1829 mm).
1231.2.26 Attorney interview space. All facilities except Type IV facilities shall include attorney interview areas which provide for confidential consultation with inmates.
Exception: The design of court holding and temporary holding facilities shall include the following required spaces from Sections 1231.2.2, 1231.2.19, 1231.2.20, 1231.2.21, 1231.2.22, 1231.2.24 and 1231.2.26.
1231.3 Design criteria for furnishings and equipment.¶
Fur- nishings and equipment shall be as follows:
1231.3.1 Toilets/urinals.
1. Toilets/urinals must be provided in single-occu- pancy cells and double-occupancy cells.
2. In dormitories, toilets/urinals must be provided in a ratio to inmates of 1:10.
3. Toilets/urinals must be accessible to the occupants of day-rooms and exercise areas.
4. In temporary holding cells and temporary staging cells toilets/urinals must be provided in a ratio to inmates of 1:16.
5. In sobering cells toilets/urinals must be provided in a ratio to inmates of 1:8.
6. One urinal or 2 feet (610 mm) of urinal trough may be substituted for each toilet up to one third of the total number of toilets required, except in those facilities or portions thereof used for females.
7. Toilet areas shall provide modesty for inmates with staff being able to visually supervise.
1231.3.2 Wash basins.
1. Wash basins must be provided in single occupancy cells and double occupancy cells.
2. In dormitories, wash basins must be provided in a ratio to inmates of 1:10.
3. Wash basins must be accessible to the occupants of day-rooms and exercise areas.
4. In temporary holding cells and temporary staging cells, wash basins must be provided in a ratio to inmates of 1:16.
5. In sobering cells, wash basins must be provided in a ratio to inmates of 1:8.
INTERIOR ENVIRONMENT
6. Wash basins must be provided with hot and cold or tempered water.
7. Two feet (610 mm) of wash basin trough may be substituted for each basin required.
1231.3.3 Drinking fountains. There must be a minimum of one drinking fountain in every single-occupancy cell, double-occupancy cell, dormitory, temporary holding cell, temporary staging cell, sobering cell, and be accessible to the occupants of day rooms and exercise areas. Additional drinking fountains shall be located in other areas of the facility so that drinking water will be available to inmates and staff. Such drinking fountains must meet the following minimum health requirements:
1. The drinking fountain bubbler shall be on an angle which prevents waste water from flowing over the drinking fountain bubbler.
2. Water flow shall be actuated by mechanical means.
1231.3.4 Showers must be available to all inmates on a ratio of at least one shower to every 20 inmates or fraction thereof and must provide hot and cold water or tempered water. Shower stalls/shower areas must be designed and constructed of materials which are impervious to water and soap so they may be easily cleaned. Shower areas shall provide modesty for inmates with staff being able to visually supervise.
ilable to all inmates on a_ ratio of at least one shower to every 20 inmates or fraction thereof and must provide hot and cold water or tempered water. Shower stalls/shower areas must be designed and constructed of materials which are impervious to water and soap so they may be easily cleaned. Shower areas shall provide modesty for inmates with staff being able to visually supervise.
1231.3.5 Beds must be elevated off the floor, have a solid bottom, and a sleeping surface of at least 30 inches (762 mm) wide and 76 inches (1930 mm) long. Multiple beds must have a minimum of 21 inches (533 mm) between bed pans. Except in minimum security areas, beds must be securely fastened to the floor or the wall.
1231.3.6 Lighting. Lighting in housing units, dayrooms and activity areas must be sufficient to permit easy read- ing by a person with normal vision, and shall not be less than 20 footcandles (215.2 lux) at desk level and in the grooming area. Lighting shall be centrally controlled and/ or occupant controlled in housing cells or rooms. Night lighting in these areas shall be sufficient to give good visi- bility for purposes of supervision. In minimum-security areas, lighting may be supplied by ordinary lighting fix- tures, and in areas of higher security, light fixtures must be of secure design.
1231.3.7 Windows. In housing areas of higher than mini- mum security, exterior windows which are constantly acces- sible to inmates for escape must be designed and constructed so that if broken out, the net area accessible for escape is no greater than 5 inches (127 mm) in one dimension.
1231.3.8 Cell padding. In sobering cells, the floor and partition shall be padded. In safety cells, padding must cover the entire floor, doors, and walls and everything on them to a clear height of 8 feet (2438 mm).
All such padded cells must be equipped with a tamper- resistant fire sprinkler as approved by the State Fire Mar- shal. All padding must be:
1. Approved for use by the State Fire Marshal;
2. Nonporous to facilitate cleaning;
Copyright © 2019 ICC. ALL RIGHTS RESERVED. Accessed by Kevin Day (kevin.day@dgs.ca.gov), (California Building Standards Commission) Order Number #100735044 on Jul 24, 2019 03:54 PM (PDT) pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Single user only, copying and networking prohibited. ANY UNAUTHORIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
100735044
INTERIOR ENVIRONMENT
3. At least 1 /2-inch (12.7 mm) thick; 4. Of a unitary or laminated construction to prevent its destruction by teeth, hand tearing or small metal objects;
5. Firmly bonded to all padded surfaces to prevent tearing or ripping; and
6. Without any exposed seams susceptible to tearing or ripping.
1231.3.9 Mirrors. A mirror of a material appropriate to the level of security must be provided near each wash basin specified in these regulations.
1231.3.10 Seating. In temporary holding and temporary staging cells, seating must be securely fixed to the floor and/or wall. When bench seating is used, 18 inches (457 mm) of bench is seating for one person.
1231.3.11 Table/seat. In single- and double-occupancy cells, a table and seat for the purpose of writing and din- ing shall be provided.
Exception: A Type I facility does not require a table and a seat.
1231.3.12 Weapons locker. A secure weapons locker shall be located outside the security perimeter of the facility. Such weapons lockers shall be equipped with individual compartments, each with an individual locking device. Weapons lockers are required in temporary and court holding facilities and in all facilities of higher than mini- mum security.
Exception: The design of court holding and tempo- rary holding facilities shall include the design criteria for furnishings and equipment from Sections 1231.3.1, 1231.3.2, 1231.3.3, 1231.3.6, 1231.3.10 and 1231.3.12.
1231.4 Enclosure of vertical openings.¶
Elevator shafts, vent shafts and other vertical openings shall be enclosed, and the enclosure shall be as set forth in Chapter 7.
1231.5 Fire-extinguishing systems.¶
Automatic fire-extin- guishing systems, standpipes and basement pipe inlets shall be installed when and as required by Chapter 9.
1231.6 Existing Group I occupancies.¶
Existing buildings housing existing protective social-care homes or facilities established prior to the effective date of these regulations may have their use continued if they conform, or are made to conform, to the following provisions.
1231.6.1 Use of floors. The use of floor levels in buildings of Type III, IV or V nonfire-rated construction may be as follows:
Nonambulatory—first floor only;
Ambulatory—not higher than the third-floor level, pro- vided walls and partitions are constructed of materials equal in fire- resistive quality to that of wood lath and plaster in good repair and all walls are firestopped at each floor level.
1231.6.2 Enclosure of exits and vertical openings. Except for two-story structures housing ambulatory guests, all interior stairs shall be enclosed in accordance with Chap- ter 10. In lieu of stairway enclosures, floor separations or smoke barriers may be provided in such a manner that fire and smoke will not spread rapidly to floors above or oth- erwise impair exit facilities. In these instances, floor sepa- rations or smoke barriers shall have a fire resistance equal to not less than 1 /2-inch (12.7 mm) gypsum wall board on each side of wood studs with openings protected by not less than a 1 3 /4-inch (44 mm) solid bonded wood- core door of the self-closing type. All other vertical open- ings shall be enclosed in accordance with the provisions of Chapter 7.
1231.6.3 Exit access. Each floor or portion thereof of buildings used for the housing of existing protective social-care homes or facilities shall have access to not less than two exits in such a manner as to furnish egress from the building or structure in the event of an emer- gency substantially equivalent to the provisions of Chapter 10.
1231.6.4 Corridor openings. Openings from rooms to interior corridors shall be protected by not less than 1 3 /4- inch (44 mm) solid-bonded wood-core doors. Transoms and other similar openings shall be sealed with materials equivalent to existing corridor wall construction.
1231.6.5 Interior wall and ceiling finishes shall conform to the requirements for a Group R, Division 1 occupancy as specified in Chapter 8.
1231.6.6 Automatic sprinkler systems shall be installed in existing protective social-care occupancies in accordance with the provisions of Chapter 9.
1231.6.7 Fire alarm systems. Automatic fire alarm sys- tems shall be installed in existing protective social-care homes or facilities in accordance with the provisions of Chapter 9.
Exception: When an approved automatic sprinkler sys- tem conforming to Chapter 9 is installed, a separate fire alarm system as specified in this subsection need not be provided.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸Contents — California Building Code (Title 24, Part 2)
- Chapter 2 — DEFINITIONS AND ABBREVIATIONS
- Appendix G — FLOOD-RESISTANT
- Appendix L — EARTHQUAKE RECORDING
- Appendix M — TSUNAMI-GENERATED
- Chapter 1 — SCOPE AND ADMINISTRATION
- Chapter 3 — OCCUPANCY CLASSIFICATION AND USE
- Chapter 4 — SPECIAL DETAILED REQUIREMENTS BASED
- Chapter 5 — GENERAL BUILDING HEIGHTS AND AREAS
- Chapter 6 — TYPES OF CONSTRUCTION
- Chapter 7 — FIRE AND SMOKE PROTECTION FEATURES
- Chapter 7A — MATERIALS AND CONSTRUCTION
- Chapter 8 — INTERIOR FINISHES
- Chapter 9 — FIRE PROTECTION AND LIFE SAFETY SYSTEMS
- Chapter 10 — MEANS OF EGRESS
- Chapter 11A — HOUSING ACCESSIBILITY
- Chapter 11B — ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMM…
▸Chapter 12 — INTERIOR ENVIRONMENT
Overview- Section 1201
- Section 1202
- Section 1203
- Section 1204
- Section 1205
- Section 1206
- Section 1207
- Section 1208
- Section 1209
- Section 1211 — [HCD 1]
- Section 1210 — [HCD 1 & HCD 2]
- Section 1212
- Section 1213
- Section 1214
- Section 1215
- Section 1216
- Section 1217
- Section 1218
- Section 1219
- Section 1220
- Section 1221
- Section 1222
- Section 1223
- Section 1224 — [OSHPD 1 & OSHPD 1R]
- Section 1225 — [OSHPD 2]
- Section 1226 — [OSHPD 3]
- Section 1227 — [OSHPD 4]
- Section 1228 — [OSHPD 5]
- Section 1229
- Section 1230 — [BSCC]
- Section 1231 — [BSCC]
- Section 1232
- Section 1233
- Section 1234
- Section 1235 — [DPH]
- Section 1236 — [DPH]
- Section 1237 — [DPH]
- Section 1238
- Section 1239
- Section 1240 — [AGR]
- Section 1241 — [AGR]
- Section 1242 — [AGR]
- Section 1243 — [AGR]
- Section 1244
- Section 1245
- Section 1246
- Section 1247
- Section 1248
- Section 1249
- Section 1250 — [CA]
- Section 1251 — [CA]
- Section 1252 — [CA]
- Section 1253 — [CA]
- Section 1254 — [CA]
- Chapter 14 — EXTERIOR WALLS
- Chapter 15 — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
- Chapter 16 — STRUCTURAL DESIGN
- Chapter 16A — STRUCTURAL DESIGN
- Chapter 17 — SPECIAL INSPECTIONS AND TESTS
- Chapter 18 — SOILS AND FOUNDATIONS
- Chapter 19 — CONCRETE
- Chapter 20 — ALUMINUM
- Chapter 21 — MASONRY
- Chapter 22 — STEEL
- Chapter 23 — WOOD
- Chapter 24 — GLASS AND GLAZING
- Chapter 25 — GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
- Chapter 26 — PLASTIC
- Chapter 27 — ELECTRICAL
- Chapter 28 — MECHANICAL SYSTEMS
- Chapter 30 — ELEVATORS AND CONVEYING SYSTEMS
- Chapter 31 — SPECIAL CONSTRUCTION
- Chapter 31B — PUBLIC POOLS
- Chapter 31C — RADIATION
- Chapter 31D — FOOD ESTABLISHMENTS
- Chapter 31F — MARINE OIL TERMINALS
- Chapter 32 — ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
- Chapter 33 — SAFEGUARDS DURING CONSTRUCTION
- Chapter 35 — REFERENCED STANDARDS
- Appendix A — EMPLOYEE QUALIFICATIONS
- Appendix B — BOARD OF APPEALS
- Appendix C — GROUP U – AGRICULTURAL BUILDINGS
- Appendix D — FIRE DISTRICTS
- Appendix F — RODENTPROOFING
- Appendix H — SIGNS
- Appendix I — PATIO COVERS
- Appendix J — GRADING
- Appendix K — GROUP R-3 AND GROUP R-3.1 OCCUPANCIES
- Appendix N — REPLICABLE BUILDINGS
- Appendix O — EMERGENCY HOUSING