Chapter 35 — REFERENCED STANDARDS

Section C102 — ALLOWABLE HEIGHT AND AREA

2025 California Building Code (Title 24, Part 2) · 2025 edition · ingested 2026-07-07 · California

Full text via GoCodebook AI

We have the complete 2025 text of this code. Ask a question and get the exact controlling section with a citation.

Ask about this chapter

C102.1 General.

C102.1 General. Buildings classified as Group U Agricultural shall not exceed the area or height limits specified in Table C102.1. TABLE C102.1—BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCYCol2Col3Col4Col5Col6Col7Col8 ------------------------ IIIIIIIII and IVIII and IVVV ABABIII A and IVIII BAB ALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)aALLOWABLE AREA (square feet)a Unlimited60,00027,10018,

C102.2 One-story unlimited area.

C102.2 One-story unlimited area. The area of a one-story Group U agricultural building shall not be limited if the building is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width.

C102.3 Two-story unlimited area.

C102.3 Two-story unlimited area. The area of a two-story Group U agricultural building shall not be limited if the building is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width and is provided with an approved automatic sprinkler system throughout in accordance with Section 903.3.1.1.