[OSHPD 1R, 2 & 5] Plain concrete footings not permitted by OSHPD.

1906.1 Plain concrete footings.

For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required thickness of plain concrete footings is permitted to be 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall.