Part 2 — PURPOSE›Chapter 3 — ELECTRICAL CODE[[5]]›8330. - ADDITION, DELETIONS, AND AMENDMENTS.
8330.1. - AMENDMENT.
Arcadia Building Code · 2026-07 edition · updated 2026-07-25 · Arcadia
Article 690.13(A) of the 2025 California Electrical Code is amended to read as follows due to local climatic and geographical conditions:
609.13(A) Location. The PV system disconnecting means shall be installed at a readily accessible location. A single, visible-open, lockable AC disconnect shall be provided within 3 feet of the meter on the exterior of the building. Where disconnecting means of systems above 30 V are readily accessible to unqualified
persons, any enclosure door or hinged cover that exposes live parts when open shall be locked or require a tool to open.
(Ord. No. 2394, § 5, 11-15-22; Ord. No. 2408, § 5, 11-18-25)
PART 4. -
(Former Part 4 was repealed by Ord. 2233 adopted 11-20-07)
CHAPTER 4. - MECHANICAL CODE[[7]]
Footnotes:
--- ( 7 ) ---
(Chapter 4 repealed and a new Chapter 4 added by Ord. 2043 adopted 12-5-95. Chapter 4 repealed and a new Chapter 4 added by Ord. 2106 adopted 7-6-99. Chapter 4 repealed and a new Chapter 4 added by Ord. 2167 adopted 11-5-02. Chapter 4 repealed and a new Chapter 4 added by Ord. 2233 adopted 11-2007)
PART 1. - ADOPTION
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Arcadia Building Code
- Article VIII — BUILDING REGULATIONS
- Part 1 — CREATION OF DIVISION
- Part 2 — DEFINITIONS
- Part 3 — VIOLATIONS
- Part 4
- Part 1 — ADOPTION
- Part 3 — ADDITIONS, DELETIONS AND AMENDMENTS[[3]]
- Part 3
- Part 1 — DECLARATION OF NEED
- Part 2 — PURPOSE
- Part 5 — DEMOLITION OF BUILDINGS
- Part 2 — SANITARY FACILITIES
- Part 4 — SWIMMING POOL REGULATIONS
- Part 5 — HOUSE NUMBERING SYSTEM
- Part 6 — SECURITY BARS
- Part 3
- Part 1 — UNREINFORCED MASONRY BEARING WALL BUILDINGS
- Part 2 — PURPOSE
- Part 3 — ADDITIONS, DELETES AND AMENDMENTS[[12]]