Division 3D.9 — TRANSPARENCY
Los Angeles Zoning Code — LAMC Chapter 1A · edición 2025 · actualizado 2026-07-08 · Los Angeles
Sec. 3D.9.1. GROUND STORY ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i
City of Los Angeles Zoning Code Chapter 1A
i
The intent of the standards of this Section (Ground Story) is to ensure projects are designed with
ground story windows that contribute to the established architectural character of surrounding
neighborhoods or district.
B. Applicability
Ground story transparency standards apply to new construction, a major remodel, or an exterior
modifcationi when the applied Character Frontage District (Div. 3B.9.) requires ground story
transparency on facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) located on the
ground story and pursuant to Sec. 3A.2.2.B.4. (Frontage Applicable Building Depth) .
C. Standards
- General
a. Standards
i. Frontage applicable facades located on the ground story shall provide no less than the minimum transparency specified in the applied Character Frontage District (Div. 3B.9.) .
ii. Frontage applicable facades located on the ground story shall provide no more than
the maximum transparency specified in the applied Character Frontage District (Div.
3B.9.) .
iii. All transparent area shall meet the standards of Sec. 3C.4.1.C. (Standards) .
b. Measurement
For transparent area measurement, see Sec. 3C.4.1.D. (Measurement) .
- Active Wall Spacing
See Sec. 3C.4.2. (Active Wall Spacing) .
- Window Recession
The depth that a window is set back from the surrounding facade.
a. Standards
All windows on applicable facades shall be recessed at a minimum depth as specified in
the applied Frontage District (Part 3B.) .
i
Sec. 3D.9.1. (Ground Story) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
| 3-116
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)
b. Measurement
i
City of Los Angeles Zoning Code Chapter 1A
i
Window recession depth is measured inward from the immediately surrounding facade
surface, exclusive of trim or accessory projecting architectural details, to the outermost
element of the window assembly.
- Bulkhead
A wall located beneath a display window on the ground story facade that elevates a window above the exterior finished grade and the interior finished floor surface.
a. Standards
i. When listed as "required" in the applied Frontage District (Part 3B.), all ground story
window openings located on applicable facades shall be located between 18 and 30 inches above the finished floor of the ground story.
ii. Ground story window openings located entirely above another ground story window
may be located greater than 30 inches from the ground story finished floor provided
that no portion of the opening extends beyond the width of the lower window
opening.
Greater than 30”
18” - 30”
i
b. Measurement
i
Bulkheads are measured as "provided" or "not provided" based on the compliance of all
applicable windows with the standards above.
- Symmetrical Lite Pattern
Window panes that are arranged or designed so that the left-side of the window composition
is a mirror image of the right-side of the window composition.
a. Standards
When listed as “required" in the applied Frontage District (Part 3B.), all windows provided
on applicable facades shall meet the following standards:
i. Divided-lite and simulated divided-lite windows shall have a composition of muntins or grills that display reflective symmetry.
ii. Operable windows shall have sashes that are reflectively symmetrical.
i
Sec. 3D.9.1. (Ground Story) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
| 3-117
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)
City of Los Angeles Zoning Code Chapter 1A
iii. Window assemblies sharing a window opening shall be composed in a way that
reflective symmetry is displayed over the entirety of the window opening.
b. Measurement
In meeting symmetrical lite pattern standards, if a vertical line can be drawn through
the window opening, and the pattern and shape on both sides of the line appear
approximately identical, the window or windows are considered in compliance with the
symmetrical lite pattern standard.
Line of Symmetry Line of Symmetry
- Horizontal Sliding Windows
| Col1 | Col2 | Col3 | Col4 | Col5 | Col6 | Col7 |
|---|---|---|---|---|---|---|
| in | in |
a. Standards
When listed as "prohibited" in the applied Frontage District (Part 3B.), windows provided on
applicable facades shall not include sashes that operate left to right or right to left.
b. Measurement
Horizontal sliding windows are identified as either present or absent.
- Vinyl Windows
a. Standards
i. When listed as "prohibited" in the applied Frontage District (Part 3B.), window
assemblies provided on applicable facades shall not contain frames, sashes, rails, styles, muntins, mullions, or grills with a vinyl exterior finish.
ii. Other accessory window assembly components may be finished with vinyl products.
b. Measurement
Vinyl windows are identified as either present or absent.
D. Exceptions
Ground story transparency standards do not apply to parking structure facades unless the applied
development standards district requires the facade to be wrapped, see Development Standards
District (Part 4B.) .
Sec. 3D.9.1. (Ground Story) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 3-118
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)
E. Relief
City of Los Angeles Zoning Code Chapter 1A
- Up to a 15 percent increase to the total allowed ground story transparent area may be granted
in accordance with Sec. 13B.5.2. (Adjustment) .
- A deviation from ground story transparency dimensional standard up to 15 percent may be
granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any ground story transparency standard may be granted as a variance in
accordance with Sec. 13B.5.3. (Variance) .
Sec. 3D.9.1. (Ground Story) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 3-119
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)
Sec. 3D.9.2. UPPER STORIES ¶
Esta sección aún no está traducida y se muestra en inglés.
A. Intent
i
City of Los Angeles Zoning Code Chapter 1A
i
The intent of the standards of this Section (Upper Stories) is to ensure projects are designed with
upper story windows that contribute to the established architectural character of surrounding
neighborhoods or districts.
B. Applicability
Upper story standards apply to new construction, a major remodel, or an exterior modifcationi
when the applied Character Frontage District (Div. 3B.9.) requires upper story transparency on
facades pursuant to Sec. 3A.2.2.B.3. (Frontage Applicable Facades) and Sec. 3A.2.2.B.4. (Frontage
Applicable Building Depth) .
C. Standards
- General
a. Standards
i. Applicable upper story facades shall provide at least the minimum transparency specified in the applied Character Frontage District (Div. 3B.9.) .
ii. Applicable upper story facades shall provide no more than the maximum transparency
specified in the applied Character Frontage District (Div. 3B.9.) .
iii. All transparent area shall meet the standards of Sec. 3C.4.1.C. (Standards) .
b. Measurement
See Sec. 3C.4.1.D.2. (Upper Stories) .
- Window Recession
See Sec. 3D.9.1.C.3. (Window Recession) .
- Symmetrical Lite Pattern
See Sec. 3D.9.1.C.5. (Symmetrical Lite Pattern) .
- Sill
The bottommost horizontal exterior surface of a window opening including a ledge or other
architectural detail that projects from the surrounding building facade.
a. Standards
i. When required by the applied Frontage District (Part 3B.), all windows provided on
applicable facades shall include a sill, ledge or comparable architectural detail located
at the bottommost exterior surface of a window opening.
i
Sec. 3D.9.2. (Upper Stories) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
i
| 3-120
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.9. (Transparency)
City of Los Angeles Zoning Code Chapter 1A
ii. Required sills shall project a minimum of one inch beyond the immediately
surrounding building facade.
iii. Required sills shall have a width of no less than the window opening.
b. Measurement
Sills are measured as "provided" or "not provided" based on the compliance of all
applicable windows with the standards of subparagraph a above.
- Horizontal Sliding Windows
See Sec. 3D.9.1.C.6. (Horizontal Sliding Windows) .
- Vinyl Windows
See Sec. 3D.9.1.C.7. (Vinyl Windows) .
D. Exceptions
Upper story transparency standards do not apply to parking structure facades unless the applied
Development Standards District (Part 4B.) requires the facade to be wrapped.
E. Relief
- Up to a 15 percent increase in the total allowed upper story transparent area may be granted in
accordance with Sec. 13B.5.2. (Adjustment) .
- A deviation up to 15 percent from upper story transparency dimensional standards may be
granted in accordance with Sec. 13B.5.2. (Adjustment) .
- Deviation from any upper story transparency standard may be granted as a variance in
accordance with Sec. 13B.5.3. (Variance) .
Sec. 3D.9.2. (Upper Stories) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 3-121
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]
Div. 3D.10. (Exterior Materials)