Division 3D.5 — STORY HEIGHT
Los Angeles Zoning Code — LAMC Chapter 1A · edición 2025 · actualizado 2026-07-08 · Los Angeles
Sec. 3D.5.1. GROUND STORY HEIGHT ¶
Esta sección aún no está traducida y se muestra en inglés.
City of Los Angeles Zoning Code Chapter 1A
For the intent, applicability, standards, measurement, and relief of ground story height see Sec. 3C.6.1.
(Ground Story Height) .
Sec. 3D.5.1. (Ground Story Height) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 3-94
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ] Div. 3D.5. (Story Height)
Sec. 3D.5.2. UPPER STORY HEIGHT ¶
Esta sección aún no está traducida y se muestra en inglés.
City of Los Angeles Zoning Code Chapter 1A
Upper story height is defined as the floor-to-floor height of any story of a building located above the
ground story.
A. Intent
The intent of the standards of this Section (Upper Story Height) is to ensure upper story spaces and
their facades are scaled and proportioned to contribute to the established architectural character
of surrounding neighborhoods or districts.
B. Applicability
- Upper story height standards apply to new construction of multi-story buildings or structures.
When upper story height standards apply, the standards apply to each story located above the ground story and all build-to applicable stories specified by the applied Frontage District (Part
3B.) .
C. Standards
All occupiable space located in applicable portions of upper stories shall have a floor-to-floor
height of no less than the upper story height minimum.
D. Measurement
- Upper story height is measured vertically from the top of the finished floor to the top of the
finished floor above.
- Where no story exists above an upper story, upper story height is the shortest vertical distance
from the top of the finished floor to the top of the ceiling or roof structure above.
E. Exceptions
Portions of upper stories located beyond the first 15 feet of a frontage applicable facade, measured
inward and perpendicular to the facade are not required to meet upper story height standards.
F. Relief
- A reduction in required upper story height of up to one foot may be granted in accordance
with Sec. 13B.5.2. (Adjustment) .
- Deviations from upper story height standards may be granted as a variance in accordance with
Sec. 13B.5.3. (Variance) .
Sec. 3D.5.2. (Upper Story Height) Established by Ord. 188,418, Eff. 01/20/2025, Oper. 01/27/2025
| 3-95
[ FORM - FRONTAGE - STANDARDS ] [ USE - DENSITY ]