The bathroom is tiled, but the inspector walks past it to the hallway ceiling and the bedrooms. In the California Residential Code, the smoke alarm trigger for an existing house is the permit, not the size of the job: "Where alterations, repairs or additions requiring a permit occur, the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings." The exceptions can release the power source and the interconnection in existing areas, but not the locations.
Key numbers
| Figure | Governs | Section |
|---|---|---|
| Any permit | Trigger for the whole dwelling unit | CRC R310.2.2 |
| Each sleeping room, outside each sleeping area, each additional story | Smoke alarm locations | CRC R310.3 |
| 3 feet | Minimum horizontal distance from a bathroom door with a tub or shower | CRC R310.3 |
| One thousand dollars | Health and Safety Code 13113.7 permit figure, not for single-family dwellings | CRC R310.8.2 |
The trigger is the permit
R310.2.2 carries no dollar amount and no room count. It points to one place for relief: "Exceptions: See Section R310.6."
A dollar figure does appear at R310.8.2, which repeats Health and Safety Code 13113.7. That text reads "for a permit for alterations, repairs, or additions, exceeding one thousand dollars". Its subsection (h) limits its reach: "This section shall not apply to the installation of smoke detectors in single-family dwellings or factory-built housing which is regulated by Section 13113.8." For a single-family house, the dollar figure is not the test in R310.2.2.
The locations are the new-dwelling locations
R310.3 lists, among others:
In each sleeping room. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each additional story of the dwelling unit, including basements and habitable attics and not including crawl spaces and uninhabitable attics.
The same list keeps alarms away from the remodeled room: "Not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by this section."
Power and interconnection have their own exceptions
R310.6 sets building wiring with a battery backup as the default. Its third exception is written for existing areas:
Smoke alarms are permitted to be solely battery operated in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior walls or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for building wiring without the removal of interior finishes.
R310.4 requires interconnection "Where more than one smoke alarm is required to be installed within an individual dwelling or sleeping unit," and its second exception uses the same test for "Smoke alarms in existing areas". Both exceptions turn on two facts: whether finishes come off in the existing areas, and whether an attic, crawl space or basement gives access.
Carbon monoxide alarms follow a different trigger
R311.2.2 applies "Where an addition is made to an existing dwelling, or a fuel-burning heater," appliance or fireplace is added. Its exceptions include "Installation, alteration or repairs of plumbing systems." Separately, R311.2.1 applies "For existing buildings and new construction" where "The dwelling unit contains a fuel-fired appliance or fireplace" or has an attached garage that communicates with it. The carbon monoxide question turns on those facts about the house, not on the bathroom permit.
What to check on the drawings
- The permit scope, because R310.2.2 turns on "requiring a permit."
- An alarm symbol at every R310.3 location: each sleeping room, outside each sleeping area, each story.
- No alarm within 3 feet horizontally of a bathroom door where the bathroom has a tub or shower.
- Which walls and ceilings lose finishes, and whether an attic, crawl space or basement reaches the bedrooms.
- Fuel-fired appliances, fireplaces and an attached garage, for R311.2.1.
Currency
The R310 and R311 pages print "California Residential Code (Title 24, Part 2.5) · 2025 edition · updated 2026-10-24" and a Cite-as line reading "Effective January 1, 2026". Neither page prints an amendment history line. Whether that edition is in force for a given jurisdiction and permit date is worth confirming first.
Frequently asked questions
Does a remodel under one thousand dollars escape the smoke alarm rule?
R310.2.2 prints no dollar figure. Its trigger is "alterations, repairs or additions requiring a permit." The dollar figure belongs to Health and Safety Code 13113.7, repeated at R310.8.2, which "shall not apply" to single-family dwellings regulated by Section 13113.8.
Do new alarms in existing bedrooms have to be hardwired?
R310.6 Exception 3 permits battery-only alarms in existing areas where the work does not expose the structure, "unless there is an attic, crawl space or basement available which could provide access for building wiring without the removal of interior finishes."
Does the bathroom itself need a smoke alarm?
R310.3 does not list bathrooms. It keeps alarms "Not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower".
Ask your own project's question in GoCodebook — your first answer is free: https://gocodebook.com/chat?utm_source=blog&utm_medium=article&utm_campaign=v4-03
Sources
- California Residential Code R310.2.2 — alterations, repairs and additions: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r310-smoke-alarms#R310.2.2
- California Residential Code R310.3 — smoke alarm locations: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r310-smoke-alarms#R310.3
- California Residential Code R310.4 — interconnection: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r310-smoke-alarms#R310.4
- California Residential Code R310.6 — power source: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r310-smoke-alarms#R310.6
- California Residential Code R310.8.2 — Health and Safety Code 13113.7: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r310-smoke-alarms#R310.8.2
- California Residential Code R311.2 — carbon monoxide alarms, where required: https://gocodebook.com/library/us/ca/ca-residential-code/chapter-3-building-planning/section-r311-carbon-monoxide-alarms#R311.2
Code text quoted as published in GoCodebook's library on 2026-11-17. This article does not replace permit review or professional judgment.