Skip to content

Victorville · Zoning · R-1 (7,200)

Victorville R-1 (7,200) zoning: height, setbacks and lot size

In Victorville's R-1 (7,200) zone, generally buildings can be up to 30 ft tall, the front setback is 20 ft and the minimum lot size is 7,200 sq. ft., with the conditions listed below (Victorville code, read October 2026).

Key points

  • Maximum building height: 30 ft
  • Minimum front setback: 20 ft (First-story living space)
  • Minimum rear setback: 20 ft
  • Minimum lot size: 7,200 sq. ft.
  • Maximum lot coverage: 40%
  • Maximum density: up to 5.0 units per gross acre

R-1 (7,200) is a zoning district in Victorville. Every value below was read from the Victorville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-1 (7,200)

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
§ 16-3.08.020 · code text
Table row “Maximum Height”, column “R-1 (7,200)”: 30
Minimum front setback
20 ft
Applies: First-story living space
§ 16-3.08.020 · code text
Table row “Porch”, column “R-1 (7,200)”: 14
Minimum rear setback
20 ft
See note 10 below the table in the code.
§ 16-3.08.020 · code text
Table row “Minimum Rear Yard Setback”, column “R-1 (7,200)”: 20 (10)
Note 10: A minimum of 15 feet, of the required 20 foot rear yard setback, is required to be useable area.
Minimum lot size
7,200 sq. ft.
§ 16-3.08.020 · code text
Table row “Minimum Net Lot Area:”, column “R-1 (7,200)”: 7,200 sq. ft.
Maximum lot coverage
40%
§ 16-3.08.020 · code text
Table row “Maximum Lot Coverage”, column “R-1 (7,200)”: 40%
Maximum density
up to 5.0 units per gross acre
§ 16-3.08.020 · code text
Table row “Maximum Dwelling Unit Density (per gross acre)”, column “R-1 (7,200)”: Up to 5.0

When a different number applies

The code sets other values for particular lots, buildings or locations in R-1 (7,200):

Not on this page

We did not find a general stories, side setback, FAR limit for R-1 (7,200) in the zoning tables we read. The code may still set one elsewhere — check the Victorville Municipal Code.

Other Victorville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Victorville's R-1 (7,200) zone?

30 ft — Victorville Municipal Code § 16-3.08.020.

What is the minimum front setback in Victorville's R-1 (7,200) zone?

20 ft (first-story living space) — Victorville Municipal Code § 16-3.08.020.

What is the minimum rear setback in Victorville's R-1 (7,200) zone?

20 ft — Victorville Municipal Code § 16-3.08.020.

What is the minimum lot size in Victorville's R-1 (7,200) zone?

7,200 sq. ft. — Victorville Municipal Code § 16-3.08.020.

What is the maximum lot coverage in Victorville's R-1 (7,200) zone?

40% — Victorville Municipal Code § 16-3.08.020.

General information, not legal advice.

Ask about a Victorville property in R-1 (7,200)

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Victorville