Skip to content

Victorville · Zoning · MU-1

Victorville MU-1 zoning: height, setbacks and lot size

In Victorville's MU-1 zone, generally buildings can be up to 45 ft tall, the front setback is 15 ft and the minimum lot size is 10,000 sq. ft., with the conditions listed below (Victorville code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Minimum front setback: 15 ft (First Story living)
  • Minimum side setback: 5 ft (Interior side)
  • Minimum rear setback: 15 ft
  • Minimum lot size: 10,000 sq. ft.
  • Maximum lot coverage: 40%
  • Maximum floor area ratio (FAR): 0.5 (Non-residential)
  • Maximum density: Up to 15.0 units per gross acre

MU-1 is a zoning district in Victorville. Every value below was read from the Victorville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in MU-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
See note 4 below the table in the code.
§ 16-3.09.020 · code text
Table row “Maximum Height”, column “Building Requirements (in ft.)”: 45 (4)
Note 4: No principal building shall exceed a height of one story when located within one hundred feet of an existing single-family residence.
Minimum front setback
15 ft
Applies: First Story living
§ 16-3.09.020 · code text
Table row “First Story living”, column “Building Requirements (in ft.)”: 15
Minimum side setback
5 ft
Applies: Interior side
§ 16-3.09.020 · code text
Table row “Interior side”, column “Building Requirements (in ft.)”: 5
Minimum rear setback
15 ft
§ 16-3.09.020 · code text
Table row “Minimum Rear Yard Setback”, column “Building Requirements (in ft.)”: 15
Minimum lot size
10,000 sq. ft.
§ 16-3.09.020 · code text
Table row “Minimum Net Lot Area”, column “Project Requirements”: 10,000 sq. ft.
Maximum lot coverage
40%
§ 16-3.09.020 · code text
Table row “Lot Coverage”, column “Project Requirements”: 40% (all types of development)
Maximum floor area ratio (FAR)
0.5
Applies: Non-residential
§ 16-3.09.020 · code text
Table row “Non-Residential Maximum Floor Area Ratio (FAR)”, column “Project Requirements”: 0.5
Maximum density
Up to 15.0 units per gross acre
§ 16-3.09.020 · code text
Table row “Maximum Dwelling Unit Density (per gross acre)”, column “Project Requirements”: Up to 15.0

When a different number applies

The code sets other values for particular lots, buildings or locations in MU-1:

Not on this page

We did not find a general stories limit for MU-1 in the zoning tables we read. The code may still set one elsewhere — check the Victorville Municipal Code.

Other Victorville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Victorville's MU-1 zone?

45 ft — Victorville Municipal Code § 16-3.09.020.

What is the minimum front setback in Victorville's MU-1 zone?

15 ft (first Story living) — Victorville Municipal Code § 16-3.09.020.

What is the minimum side setback in Victorville's MU-1 zone?

5 ft (interior side) — Victorville Municipal Code § 16-3.09.020.

What is the minimum rear setback in Victorville's MU-1 zone?

15 ft — Victorville Municipal Code § 16-3.09.020.

What is the minimum lot size in Victorville's MU-1 zone?

10,000 sq. ft. — Victorville Municipal Code § 16-3.09.020.

General information, not legal advice.

Ask about a Victorville property in MU-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Victorville