Victorville M-1 zoning: height, setbacks and lot size

In Victorville's M-1 zone, buildings can be up to 50 ft tall, the front setback is 10 ft and the minimum lot size is 30,000 sq ft (Victorville code, read October 2026).

Key points

  • Maximum building height: 50 ft
  • Minimum front setback: 10 ft
  • Minimum side setback: None required (Interior side yard not next to a residential district)
  • Minimum rear setback: None required (Interior rear yard not next to a residential district)
  • Minimum lot size: 30,000 sq ft
  • Maximum lot coverage: 60%
  • Maximum floor area ratio (FAR): 1.0

M-1 is a zoning district in Victorville. Every value below was read from the Victorville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in M-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
§ 16-3.11.020 · code text
Table row “Maximum Building Height”, column “M-1”: 50
Minimum front setback
10 ft
§ 16-3.11.020 · code text
Table row “Front Yard Setback”, column “M-1”: 10
Minimum side setback
None required
Applies: Interior side yard not next to a residential district
§ 16-3.11.020 · code text
Table row “Interior side”, column “M-1”: None
Minimum rear setback
None required
Applies: Interior rear yard not next to a residential district
§ 16-3.11.020 · code text
Table row “Interior rear”, column “M-1”: None
Minimum lot size
30,000 sq ft
§ 16-3.11.020 · code text
Table row “Minimum Net Lot Area”, column “M-1”: 30,000 sq ft
Maximum lot coverage
60%
§ 16-3.11.020 · code text
Table row “Maximum Lot Coverage”, column “M-1”: 60%
Maximum floor area ratio (FAR)
1.0
§ 16-3.11.020 · code text
Table row “Maximum Floor Area Ratio (FAR)”, column “M-1”: 1.0

When a different number applies

The code sets other values for particular lots, buildings or locations in M-1:

  • Minimum side setback: 10 ft — Street side § 16-3.11.020
  • Minimum rear setback: 10 ft — Rear yard along a street § 16-3.11.020
  • Minimum rear setback: 30 ft — Along any rear or side lot line that abuts a residential district not separated by a public right-of-way; required setback increased by 30 feet when building height exceeds 30 feet § 16-3.11.020

Not on this page

We did not find a general stories, density limit for M-1 in the zoning tables we read. The code may still set one elsewhere — check the Victorville Municipal Code.

Other Victorville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Victorville's M-1 zone?

50 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum front setback in Victorville's M-1 zone?

10 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum side setback in Victorville's M-1 zone?

None required (interior side yard not next to a residential district) — Victorville Municipal Code § 16-3.11.020.

What is the minimum rear setback in Victorville's M-1 zone?

None required (interior rear yard not next to a residential district) — Victorville Municipal Code § 16-3.11.020.

What is the minimum lot size in Victorville's M-1 zone?

30,000 sq ft — Victorville Municipal Code § 16-3.11.020.

General information, not legal advice.

Ask about a Victorville property in M-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question