Skip to content

Santa Monica · Zoning · PL

Santa Monica PL zoning: height, setbacks and lot size

In Santa Monica's PL zone, buildings can be up to 32 ft (2 stories) tall, the front setback is 10 ft and the minimum lot size is 20,000 sq ft (Santa Monica code, read October 2026).

Key points

  • Maximum building height: 32 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 10 ft
  • Minimum side setback: 10 ft (15 ft when abutting a residential district)
  • Minimum rear setback: 10 ft (15 ft when abutting a residential district)
  • Minimum lot size: 20,000 sq ft

PL (Public District) is a zoning district in Santa Monica. Every value below was read from the Santa Monica Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in PL

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
32 ft
§ 9.15.030 · code text
Table row “Maximum Building Height (stories/ft.)”, column “PL”: 2/32'
Maximum number of stories
2 stories
§ 9.15.030 · code text
Table row “Maximum Building Height (stories/ft.)”, column “PL”: 2/32'
Minimum front setback
10 ft
§ 9.15.030 · code text
Table row “Street Frontage”, column “PL”: 10'
Minimum side setback
10 ft
Applies: 15 ft when abutting a residential district
§ 9.15.030 · code text
Table row “Interior Side and Rear”, column “PL”: 10'; 15' when abutting a residential district
Minimum rear setback
10 ft
Applies: 15 ft when abutting a residential district
§ 9.15.030 · code text
Table row “Interior Side and Rear”, column “PL”: 10'; 15' when abutting a residential district
Minimum lot size
20,000 sq ft
§ 9.15.030 · code text
Table row “Minimum Parcel Size (sq. ft.)”, column “PL”: 20,000

Uses in PL

Uses the code's use tables allow in PL, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in PL:

  • Minimum side setback: 15 ft — when abutting a residential district § 9.15.030
  • Minimum rear setback: 15 ft — when abutting a residential district § 9.15.030

Not on this page

We did not find a general lot coverage, FAR, density limit for PL in the zoning tables we read. The code may still set one elsewhere — check the Santa Monica Municipal Code.

Other Santa Monica zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Santa Monica's PL zone?

32 ft — Santa Monica Municipal Code § 9.15.030.

What is the maximum number of stories in Santa Monica's PL zone?

2 stories — Santa Monica Municipal Code § 9.15.030.

What is the minimum front setback in Santa Monica's PL zone?

10 ft — Santa Monica Municipal Code § 9.15.030.

What is the minimum side setback in Santa Monica's PL zone?

10 ft (15 ft when abutting a residential district) — Santa Monica Municipal Code § 9.15.030.

What is the minimum rear setback in Santa Monica's PL zone?

10 ft (15 ft when abutting a residential district) — Santa Monica Municipal Code § 9.15.030.

General information, not legal advice.

Ask about a Santa Monica property in PL

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question