Skip to content

Milpitas · Zoning · C1

Milpitas C1 zoning: height, setbacks and lot size

In Milpitas's C1 zone, buildings can be up to 35 ft (3 stories) tall and the front setback is 0 ft (Milpitas code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 3 stories
  • Minimum front setback: 0 ft
  • Minimum side setback: 0 ft (15 ft when abutting a residential zone)
  • Minimum rear setback: 0 ft (15 ft when abutting a residential zone)
  • Maximum floor area ratio (FAR): 0.75

C1 is a zoning district in Milpitas. Every value below was read from the Milpitas Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ B.6.030 · code text
Table row “Primary Building Height, max.”, column “C1”: 35 ft; 3 stories 2
Maximum number of stories
3 stories
§ B.6.030 · code text
Table row “Primary Building Height, max.”, column “C1”: 35 ft; 3 stories 2
Minimum front setback
0 ft
§ B.6.030 · code text
Table row “Front”, column “C1”: 0
Minimum side setback
0 ft
Applies: 15 ft when abutting a residential zone
§ B.6.030 · code text
Table row “Interior side”, column “C1”: 0; 15 when abutting a residential zone
Minimum rear setback
0 ft
Applies: 15 ft when abutting a residential zone
§ B.6.030 · code text
Table row “Rear”, column “C1”: 0; 15 when abutting a residential zone
Maximum floor area ratio (FAR)
0.75
§ B.6.030 · code text
Table row “FAR, max.”, column “C1”: 0.75

Uses in C1

Uses the code's use tables allow in C1, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in C1:

  • Minimum side setback: 15 ft — When abutting a residential zone § B.6.030
  • Minimum rear setback: 15 ft — When abutting a residential zone § B.6.030

Not on this page

We did not find a general lot size, lot coverage, density limit for C1 in the zoning tables we read. The code may still set one elsewhere — check the Milpitas Municipal Code.

Other Milpitas zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Milpitas's C1 zone?

35 ft — Milpitas Municipal Code § B.6.030.

What is the maximum number of stories in Milpitas's C1 zone?

3 stories — Milpitas Municipal Code § B.6.030.

What is the minimum front setback in Milpitas's C1 zone?

0 ft — Milpitas Municipal Code § B.6.030.

What is the minimum side setback in Milpitas's C1 zone?

0 ft (15 ft when abutting a residential zone) — Milpitas Municipal Code § B.6.030.

What is the minimum rear setback in Milpitas's C1 zone?

0 ft (15 ft when abutting a residential zone) — Milpitas Municipal Code § B.6.030.

General information, not legal advice.

Ask about a Milpitas property in C1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Milpitas