CRSC · California Referenced Standards Code

Product approval and independent evaluation

CRSC Chapters 12‑11A/12‑11B require independent evaluation, selection by the Division of the State Architect, and biennial recertification for detectable warning products and directional surfaces.

Last reviewed: July 6, 2026

Overview

This portion of the California Referenced Standards Code (CRSC) establishes how certain products — most notably detectable warning products and directional surfaces — are evaluated, approved and kept in service through independent testing and periodic recertification. The CRSC locates these requirements mainly in Chapters 12‑11A and 12‑11B and sets the scope and test-method expectations for product approval (see §§ 12‑11A.202–12‑11B.204).

The CRSC requires evaluation by an independent entity to confirm both prescriptive and performance standards, defines the selecting authority (Division of the State Architect — Access Compliance) and requires re‑certification cycles and fee mechanisms (see §§ 12‑11A.205–.208 and §§ 12‑11A.209–.211 on durability and selection). These provisions make independent evaluation the primary path for demonstrating compliance for the specified product categories.

Practically, manufacturers and specifiers should expect submission of test data and labeling/listing information, acceptance to be tied to the independent entity’s evaluation, and mandatory follow‑up recertification (including the two‑year recertification requirement for the specified products). The CRSC’s general test, component and marking rules (for example, the guidance on components and marking requirements) apply alongside the product‑specific chapters.

In this section

Code references

Grounded in the retrieved California Referenced Standards Code — click a citation to read the verbatim passage:

  • CRSC § 1703.1.1 High relevance — show source text

    1703.1.1 Independence. An approved agency shall be objective, competent and independent from the contractor responsible for the work being inspected. The agency shall disclose to the building official and the registered design professional in responsible charge possible conflicts of interest so that objectivity can be confirmed.

    1703.1.2 Equipment. An approved agency shall have adequate equipment to perform required tests. The equipment shall be periodically calibrated.

    1703.1.3 Personnel. An approved agency shall employ experienced personnel educated in conducting, supervising and evaluating tests and special inspections.

    1703.2 Written approval. Any material, appliance, equipment, system or method of construction meeting the requirements of this code shall be approved in writing after satisfactory completion of the required tests and submission of required test reports.

    1703.3 Record of approval. For any material, appliance, equipment, system or method of construction that has been approved, a record of such approval, including the conditions and limitations of the approval, shall be kept on file in the building official’s office and shall be available for public review at appropriate times.

    1703.4 Performance. Specific information consisting of test reports conducted by an approved agency in accordance with the appropriate referenced standards, or other such information as necessary, shall be provided for the building official to determine that the product, material or assembly meets the applicable code requirements.

    2025 CALIFORNIA BUILDING CODE 17-3

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    SPECIAL INSPECTIONS AND TESTS

    [OSHPD 1R, 2 & 5] Tests performed by an independent approved testing agency/laboratory or under the responsible charge of a compe- tent approved independent Registered Design Professional shall be deemed to comply with requirements of this section. Test reports for structural tests shall be reviewed and accepted by an independent California licensed structural engineer.

    1703.4.1 Research and investigation. Sufficient technical data shall be submitted to the building official to substantiate the proposed use of any product, material or assembly. If it is determined that the evidence submitted is satisfactory proof of performance for the use intended, the building official shall approve the use of the product, material or assembly subject to the requirements of this code. The costs, reports and investigations required under these provisions shall be paid by the owner or the owner’s authorized agent.

    1703.4.2 Research reports. Supporting data, where necessary to assist in the approval of products, materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.

    1703.5 Labeling. Products, materials or assemblies required to be labeled shall be labeled in accordance with the procedures set forth in Sections 1703.5.1 through 1703.5.4.

    1703.5.1 Testing. An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The approved agency shall maintain a record of the tests performed. The record shall provide sufficient detail to verify compliance with the test standard.

    1703.5.2 Inspection and identification. The approved agency shall periodically perform an inspection, which shall be in-plant if necessary, of the product or material that is to be labeled. The inspection shall verify that the labeled product, material or assembly is representative of the product, material or assembly tested.

  • CRSC § 1.1 High relevance — show source text

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    SPECIAL INSPECTIONS AND TESTS

    1703 A .1.1 Independence. An approved agency shall be objective, competent and independent from any other entity providing inspection services and contractor (s) responsible for the work being inspected. The agency shall disclose to the building official and the registered design professional in responsible charge possible conflicts of interest so that objectivity can be confirmed.

    1703 A .1.2 Equipment. An approved agency shall have adequate equipment to perform required tests. The equipment shall be periodically calibrated.

    1703 A .1.3 Personnel. An approved agency shall employ experienced personnel educated in conducting, supervising and evaluating tests and special inspections.

    1703 A .2 Written approval. Any material, appliance, equipment, system or method of construction meeting the requirements of this code shall be approved in writing after satisfactory completion of the required tests and submission of required test reports.

    1703 A .3 Record of approval. For any material, appliance, equipment, system or method of construction that has been approved, a record of such approval, including the conditions and limitations of the approval, shall be kept on file in the building official’s office and shall be available for public review at appropriate times.

    1703 A .4 Performance. Specific information consisting of test reports conducted by an approved agency in accordance with the appropriate referenced standards, or other such information as necessary, shall be provided for the building official to determine that the product, material or assembly meets the applicable code requirements.

    [OSHPD 1 & 4] Tests performed by an independent approved testing agency/laboratory or under the responsible charge of a compe- tent approved independent Registered Design Professional shall be deemed to comply with requirements of this section. Test reports for structural tests shall be reviewed and accepted by an independent California licensed structural engineer.

    1703 A .4.1 Research and investigation. Sufficient technical data shall be submitted to the building official to substantiate the proposed use of any product, material or assembly. If it is determined that the evidence submitted is satisfactory proof of performance for the use intended, the building official shall approve the use of the product, material or assembly subject to the requirements of this code. The costs, reports and investigations required under these provisions shall be paid by the owner or the owner’s authorized agent.

    1703 A .4.2 Research reports. Supporting data, where necessary to assist in the approval of products, materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.

    1703 A .5 Labeling. Products, materials or assemblies required to be labeled shall be labeled in accordance with the procedures set forth in Sections 1703 A .5.1 through 1703 A .5.4.

    1703 A .5.1 Testing. An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The approved agency shall maintain a record of the tests performed. The record shall provide sufficient detail to verify compliance with the test standard.

  • CRSC § 12-11 Medium relevance — show source text

    DETECTABLE WARNING PRODUCTS

    Sections 12-11A.203 and 12-11B.203. Must comply with the California Code of Regulations, Title 24.

    DIRECTIONAL SURFACES

    Sections 12-11A.204 and 12-11B.204. Must comply with the California Code of Regulations, Title 24.

    INDEPENDENT ENTITY

    Sections 12-11A.205 and 12-11B.205. Evaluation by an independent entity to confirm the prescriptive and performance standard of detectable warning products or direction surfaces installed after January 1, 2001. An independent entity is a not-for-profit product safety testing and certification organization, dedicated to testing for public safety. An independent entity would operate for the testing, certification and quality assessment of products, systems and services.

    TWO-YEAR APPROVAL

    Sections 12-11A.206 and 12-11B.206. Detectable warning products and directional surfaces are to be recertified every two years without exception or waiver.

    FEE

    Sections 12-11A.207 and 12-11B.207. The Division of the State Architect-Access Compliance may impose a fee on manufacturers of the specified products, to cover the cost of detectable warning products and directional surfaces.

    DISABILITY ACCESS ACCOUNT

    Sections 12-11A.208 and 12-11B.208. The fees received from manufacturers will be placed in the Disability Access Account.

    DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES

    Sections 12-11A.209 and 12-11B.209. Detectable Warning Products and Directional Surfaces must ensure consistency and uniformity: (a) Shape, (b) Color fastness,

    (c) Conformation, (d) Sound-on-cane acoustic quality, (e) Resilience, and (f) Attachment will not degrade significantly for at least five years.

    SIGNIFICANT DEGRADATION

    Sections 12-11A.210 and 12-11B.210. Significant degradation means that the product maintains at least 90 percent of its approved design characteristics.

    SELECTION OF INDEPENDENT ENTITY

    Sections 12-11A.211 and 12-11B.211. The independent entity selected by the Division of the State Architect-Access Compliance shall be recognized as having appropriate expertise in determining whether products comply with the California Code of Regulations, Title 24.

    Authority: Government Code Sections 4450, 4460 and Health & Safety Code Section 18949.1.

    Reference: Government Code Section 4460.

    2025 CALIFORNIA REFERENCED STANDARDS CODE 85

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    86 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    2025 CALIFORNIA REFERENCED STANDARDS CODE 87

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    88 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    12-13 STANDARDS FOR INSULATING MATERIAL

    (See Part 6, Title 24, CCR)

    DEPARTMENT OF CONSUMER AFFAIRS

    Bureau of Household Goods and Services

  • CRSC § 12-11 Medium relevance — show source text

    (c) Conformation, (d) Sound-on-cane acoustic quality, (e) Resilience, and (f) Attachment will not degrade significantly for at least five years.

    SIGNIFICANT DEGRADATION

    Sections 12-11A.210 and 12-11B.210. Significant degradation means that the product maintains at least 90 percent of its approved design characteristics.

    SELECTION OF INDEPENDENT ENTITY

    Sections 12-11A.211 and 12-11B.211. The independent entity selected by the Division of the State Architect-Access Compliance shall be recognized as having appropriate expertise in determining whether products comply with the California Code of Regulations, Title 24.

    Authority: Government Code Sections 4450, 4460 and Health & Safety Code Section 18949.1.

    Reference: Government Code Section 4460.

    2025 CALIFORNIA REFERENCED STANDARDS CODE 85

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    86 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    2025 CALIFORNIA REFERENCED STANDARDS CODE 87

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    88 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    12-13 STANDARDS FOR INSULATING MATERIAL

    (See Part 6, Title 24, CCR)

    DEPARTMENT OF CONSUMER AFFAIRS

    Bureau of Household Goods and Services

    ARTICLE 3. STANDARDS FOR INSULATING MATERIAL

    APPLICATION AND SCOPE

    Sec. 12-13-1551.

    (a) This article establishes standards governing the quality of insulation sold within the state after September 22, 1981, including those properties which affect the safety and thermal performance of insulation during application and in the use intended.

    (b) The provisions of this article shall apply only to the following types of insulating material:

    1. Aluminum foil (reflective foil);

    2. Cellular glass (board form);

    3. Cellulose fiber (loose fill and spray applied);

    4. Mineral aggregate (board form);

    5. Mineral fiber (blankets, board form, loose fill);

    6. Perlite (loose fill);

    7. Polystyrene (board form, molded and extruded);

    8. Polyurethane (board form and field applied);

    9. Polyisocyanurate (board form and field applied);

    10. Urea formaldehyde foam (field applied);

    11. Vermiculite (loose fill).

    (c) The provisions of this article shall apply to the sale of insulating material within the state. The provisions of this article shall not apply to insulating material manufactured in California, but sold outside the state, nor to insulating material manufactured outside California and sold wholesale in California for final retail sale outside the state. For the purpose of this article, the sale of a building or an appliance which contains installed insulating material is not considered the sale of the insulating material.

    (d) Any type of insulating material not listed in subsection (b) may be sold within California notwithstanding any other provision of this article.

    Authority: Sections 25920 and 25922, Public Resources Code.

    Reference: Sections 25910, 25920, 25921 and 25922, Public Resources Code.

  • CRSC § 12-10 Medium relevance — show source text

    (f) Release bar deformation. The cross-bar on a 36-inch (914 mm) wide door shall not be permanently set or deformed in excess of [1] / 4 inch (6 mm), by the test; a spacing of at least 1 inch (25 mm) is to be provided and maintained between the cross-bar and the face of the door when the horizontal force is applied against the cross-bar.

    MARKING

    Sec. 12-10-306. The listee’s name (or approved symbol), type or model designation shall be plainly marked on the releasing assembly. Devices and assemblies which are not listed by an approved listing agency for the intended purpose shall bear a label or other identifying markings as approved by the State Fire Marshal.

    84 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CHAPTERS

    12-11A and 11B BUILDING AND FACILITY ACCESS SPECIFICATIONS

    Detectable warning products and directional surfaces installed after January 1, 2001, shall be evaluated by an independent entity, selected by the Department of General Services, Division of the State Architect-Access Compliance, for all occupancies, including transportation and other outdoor environments, except that when products and surfaces are for use in residential housing evaluation shall be in consultation with the Department of Housing and Community Development. See Government Code Section 4460.

    PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES

    SCOPE

    Sections 12-11A.202 and 12-11B.202. These requirements and test methods apply to detectable warning products and directional surfaces.

    DETECTABLE WARNING PRODUCTS

    Sections 12-11A.203 and 12-11B.203. Must comply with the California Code of Regulations, Title 24.

    DIRECTIONAL SURFACES

    Sections 12-11A.204 and 12-11B.204. Must comply with the California Code of Regulations, Title 24.

    INDEPENDENT ENTITY

    Sections 12-11A.205 and 12-11B.205. Evaluation by an independent entity to confirm the prescriptive and performance standard of detectable warning products or direction surfaces installed after January 1, 2001. An independent entity is a not-for-profit product safety testing and certification organization, dedicated to testing for public safety. An independent entity would operate for the testing, certification and quality assessment of products, systems and services.

    TWO-YEAR APPROVAL

    Sections 12-11A.206 and 12-11B.206. Detectable warning products and directional surfaces are to be recertified every two years without exception or waiver.

    FEE

    Sections 12-11A.207 and 12-11B.207. The Division of the State Architect-Access Compliance may impose a fee on manufacturers of the specified products, to cover the cost of detectable warning products and directional surfaces.

    DISABILITY ACCESS ACCOUNT

    Sections 12-11A.208 and 12-11B.208. The fees received from manufacturers will be placed in the Disability Access Account.

    DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES

    Sections 12-11A.209 and 12-11B.209. Detectable Warning Products and Directional Surfaces must ensure consistency and uniformity: (a) Shape, (b) Color fastness,

  • CRSC § 4.1 Medium relevance — show source text

    [OSHPD 1 & 4] Tests performed by an independent approved testing agency/laboratory or under the responsible charge of a compe- tent approved independent Registered Design Professional shall be deemed to comply with requirements of this section. Test reports for structural tests shall be reviewed and accepted by an independent California licensed structural engineer.

    1703 A .4.1 Research and investigation. Sufficient technical data shall be submitted to the building official to substantiate the proposed use of any product, material or assembly. If it is determined that the evidence submitted is satisfactory proof of performance for the use intended, the building official shall approve the use of the product, material or assembly subject to the requirements of this code. The costs, reports and investigations required under these provisions shall be paid by the owner or the owner’s authorized agent.

    1703 A .4.2 Research reports. Supporting data, where necessary to assist in the approval of products, materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.

    1703 A .5 Labeling. Products, materials or assemblies required to be labeled shall be labeled in accordance with the procedures set forth in Sections 1703 A .5.1 through 1703 A .5.4.

    1703 A .5.1 Testing. An approved agency shall test a representative sample of the product, material or assembly being labeled to the relevant standard or standards. The approved agency shall maintain a record of the tests performed. The record shall provide sufficient detail to verify compliance with the test standard.

    1703 A .5.2 Inspection and identification. The approved agency shall periodically perform an inspection, which shall be in-plant if necessary, of the product or material that is to be labeled. The inspection shall verify that the labeled product, material or assembly is representative of the product, material or assembly tested.

    1703 A .5.3 Label information. The label shall contain the manufacturer’s identification, model number, serial number or definitive information describing the performance characteristics of the product, material or assembly and the approved agency’s identification.

    1703 A .5.4 Method of labeling. Information required to be permanently identified on the product, material or assembly shall be acid etched, sand blasted, ceramic fired, laser etched, embossed or of a type that, once applied, cannot be removed without being destroyed.

    1703 A .6 Evaluation and follow-up inspection services. Where structural components or other items regulated by this code are not visible for inspection after completion of a prefabricated assembly, the owner or the owner’s authorized agent shall submit a report of each prefabricated assembly. The report shall indicate the complete details of the assembly, including a description of the assembly and its components, the basis upon which the assembly is being evaluated, test results and similar information and other data as necessary for the building official to determine conformance to this code. Such a report shall be approved by the building official.

    1703 A .6.1 Follow-up inspection. The owner or the owner’s authorized agent shall provide for special inspections of fabricated items in accordance with Section 1704 A .2.5.

    1703 A .6.2 Test and inspection records. Copies of necessary test and special inspection records shall be filed with the building official.

  • CRSC § 321.2.1 Medium relevance — show source text

    321.2.1 The approach used in the development of the design shall be acceptable to the peer reviewer and the enforcement agency and shall be the same method as used in the evaluation of the building. Approaches that are specifically tailored to the type of building, construction materials and specific building characteristics may be used, if they are acceptable to the independent peer reviewer. The use of Method A allowed procedures may also be used under Method B.

    321.2.2 Any method of analysis may be used, subject to acceptance by the peer reviewer(s) and the building official. The general requirements given in ASCE 41, Chapters 6 and 7, shall be complied with unless exceptions are accepted by the peer reviewer(s) and building official. Use of other than ASCE 41 procedures in Method B requires building official concurrence before implementation.

    321.2.3 Prior to implementation, the procedures, methods, material assumptions and acceptance/rejection criteria proposed by the registered design professional will be peer reviewed as provided in Section 322. Where nonlinear procedures are used, prior to any analysis, the representation of the seismic ground motion shall be reviewed and approved by the peer reviewer(s) and the building official.

    [DSA-SS, DSA-SS/CC] For public school and community college projects, the representation of the seismic ground motion shall be reviewed and approved by the California Geological Survey.

    321.2.4 The conclusions and design decisions shall be reviewed and accepted by the peer reviewer(s) and the building official.

    SECTION 322 [BSC, DSA-SS & DSA-SS/CC]—PEER REVIEW REQUIREMENTS

    322.1 General. Independent peer review is an objective, technical review by knowledgeable reviewer(s) experienced in the structural design, analysis and performance issues involved. The reviewer(s) shall examine the available information on the condition of the building, the basic engineering concepts employed and the recommendations for action.

    322.2 Timing of independent review. The independent reviewer(s) shall be selected prior to initiation of substantial portions of the design and/or analysis work that is to be reviewed, and review shall start as soon as practical after Method B is adopted and sufficient information defining the project is available.

    322.3 Qualifications and terms of employment. The reviewer(s) shall be independent from the design and construction team.

    322.3.1 The reviewer(s) shall have no other involvement in the project before, during or after the review, except in a review capacity.

    2025 CALIFORNIA EXISTING BUILDING CODE 3-21

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    PROVISIONS FOR ALL COMPLIANCE METHODS

    322.3.2 The reviewer(s) shall be selected and paid by the owner and shall have technical expertise in the evaluation and retrofit of buildings similar to the one being reviewed, as determined by the enforcement agency.

    322.3.3 The reviewer (or in the case of review teams, the chair) shall be a California-licensed structural engineer who is familiar with the technical issues and regulations governing the work to be reviewed.

    Exception: Other individuals with acceptable qualifications and experience may be a peer reviewer(s) with the approval of the building official.

  • CRSC § 104.2.3.4 Medium relevance — show source text

    [A] 104.2.3.4 Equivalency criteria. An alternative material, design or method of construction shall, for the purpose intended, be not less than the equivalent of that prescribed in this code with respect to all of the following, as applicable:

    1. Quality.

    2. Strength.

    3. Effectiveness.

    4. Durability.

    5. Safety, other than fire safety.

    6. Fire safety.

    [A] 104.2.3.5 Tests. Tests conducted to demonstrate equivalency in support of an alternative material, design or method of construction application shall be of a scale that is sufficient to predict performance of the end use configuration. Tests shall be performed by a party acceptable to the fire code official.

    [A] 104.2.3.5.1 Fire tests. Tests conducted to demonstrate equivalent fire safety in support of an alternative material, design or method of construction application shall be of a scale that is sufficient to predict fire safety performance of the end use configuration. Tests shall be performed by a party acceptable to the fire code official.

    [A] 104.2.3.6 Reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall comply with Sections 104.2.3.6.1 and 104.2.3.6.2.

    [A] 104.2.3.6.1 Evaluation reports. Evaluation reports shall be issued by an approved agency and use of the evaluation report shall require approval by the fire code official for the installation. The alternate material, design or method of construction and product evaluated shall be within the scope of the fire code official’s recognition of the approved agency. Criteria used for the evaluation shall be identified within the report and, where required, provided to the fire code official.

    [A] 104.2.3.6.2 Other reports. Reports not complying with Section 104.2.3.6.1 shall describe criteria, including but not limited to any referenced testing or analysis, used to determine compliance with code intent and justify code equivalence. The report shall be prepared by a qualified engineer, specialist, laboratory or fire safety specialty organization acceptable to the fire code official. The fire code official is authorized to require design submittals to be prepared by, and bear the stamp of, a registered design professional.

    2025 CALIFORNIA FIRE CODE 1-15

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    DIVISION II—SCOPE AND ADMINISTRATION

    [A] 104.2.3.7 Peer review. The fire code official is authorized to require submittal of a peer review report in conjunction with a request to use an alternative material, design or method of construction, prepared by a peer reviewer that is approved by the fire code official.

    104.2.4 Modifications. Where there are practical difficulties involved in carrying out the provisions of this code, the fire code official shall have the authority to grant modifications in accordance with Section 104.2.4.1 or 104.2.4.2.

    104.2.4.1 Individual cases. The fire code official shall have the authority to grant modifications for individual cases, provided that the fire code official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, life and fire safety requirements. The details of action granting modifications shall be recorded and entered in the files of the code compliance agency.

  • CRSC § 2.2 Medium relevance — show source text

    R104.2.2 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved.

    R104.2.2.1 Approval authority. An alternative material, design or method of construction shall be approved where the building official finds that the proposed alternative is satisfactory and complies with Sections R104.2.2 through R104.2.2.6.2, as applicable.

    R104.2.2.2 Application and disposition. Where required, a request to use an alternative material, design or method of construction shall be submitted in writing to the building official for approval. Where the alternative material, design or method of construction is not approved, the building official shall respond in writing, stating the reasons the alternative was not approved.

    R104.2.2.3 Compliance with code intent. An alternative material, design or method of construction shall comply with the intent of the provisions of this code.

    R104.2.2.4 Equivalency criteria. An alternative material, design or method of construction shall, for the purpose intended, be not less than the equivalent of that prescribed in this code with respect to all the following, as applicable:

    1. Quality.

    2. Strength.

    3. Effectiveness.

    4. Durability.

    5. Safety, other than fire safety.

    6. Fire safety.

    R104.2.2.5 Tests. Tests conducted to demonstrate equivalency in support of an alternative material, design or method of construction application shall be of a scale that is sufficient to predict performance of the end use configuration. Such tests shall be performed by a party acceptable to the building official.

    1-18 2025 CALIFORNIA RESIDENTIAL CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    DIVISION II SCOPE AND ADMINISTRATION

    R104.2.2.6 Reports. Supporting documentation, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall comply with Sections R104.2.2.6.1 and R104.2.2.6.2.

    R104.2.2.6.1 Evaluation reports. Evaluation reports shall be issued by an approved agency and use of the evaluation report shall require approval by the building official for the installation. The alternate material, design or method of construction and product evaluated shall be within the scope of the building official’s recognition of the approved agency. Criteria used for the evaluation shall be identified within the report and, where required, provided to the building official.

    R104.2.2.6.2 Other reports. Reports not complying with Section R104.2.2.6.1 shall describe criteria, including but not limited to any referenced testing or analysis, used to determine compliance with code intent and justify code equivalence. The report shall be prepared by a qualified engineer, specialist, laboratory or specialty organization acceptable to the building official. The building official is authorized to require design submittals to be prepared by, and bear the stamp of, a registered design professional.

  • CRSC § 12-10 Medium relevance — show source text

    Note: Mechanisms involving dead-locking bolts may require modification in the test procedure in order to simulate the intended in-service condition. Modifications in the test procedure shall be filed for evaluation and approval before proceeding with the test.

    (d) Releasing pressure. The motor-driven mechanism shall be arranged to apply not to exceed 15 pounds pressure against the cross-bar to release the door latch(es) or dead-locking bolts before the door is pushed open.

    (e) Cycle test. The release mechanism and latches or dead-locking bolts shall function as intended for 100,000 cycles of operation without failure or excessive wear of the parts.

    EMERGENCY OPERATION TEST

    Sec. 12-10-305.

    (a) Releasing pressure. The release mechanism shall be so designed that a horizontal force of 50 pounds or less will actuate the release bar and latches or dead-locking bolt when the latched or locked door is subjected to outward pressure as described in Sections 12-10-305 (c) and (d). The horizontal force shall be applied at any point along the cross-bar perpendicular to the door in the direction of swing.

    (b) Test specimen. The test specimen for the emergency operation test shall be the sample which has been previously subjected to the cycle test specified in Section 12-10-304.

    (c) Testing instrument. The horizontal force applied to the cross-bar shall be measured with a calibrated spring scale or other approved means.

    (d) Outward pressure, single door. A hydraulic loading device or load dynamometer shall be used to apply a horizontal force of 250 pounds against the latching edge in the direction in which the door opens. The thrust load shall be applied to the stile immediately above the latching mechanism.

    (e) Outward pressure, double doors. A hydraulic loading device or load dynamometer shall be used to apply a horizontal force of 250 pounds against the lock stile of each door of doors in pairs 2 inches (51 mm) in from the edge at midpoint between top and bottom of each door leaf in the direction of door swing.

    (f) Release bar deformation. The cross-bar on a 36-inch (914 mm) wide door shall not be permanently set or deformed in excess of [1] / 4 inch (6 mm), by the test; a spacing of at least 1 inch (25 mm) is to be provided and maintained between the cross-bar and the face of the door when the horizontal force is applied against the cross-bar.

    MARKING

    Sec. 12-10-306. The listee’s name (or approved symbol), type or model designation shall be plainly marked on the releasing assembly. Devices and assemblies which are not listed by an approved listing agency for the intended purpose shall bear a label or other identifying markings as approved by the State Fire Marshal.

    84 2025 CALIFORNIA REFERENCED STANDARDS CODE

    on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.

    CHAPTERS

    12-11A and 11B BUILDING AND FACILITY ACCESS SPECIFICATIONS

    Detectable warning products and directional surfaces installed after January 1, 2001, shall be evaluated by an independent entity, selected by the Department of General Services, Division of the State Architect-Access Compliance, for all occupancies, including transportation and other outdoor environments, except that when products and surfaces are for use in residential housing evaluation shall be in consultation with the Department of Housing and Community Development. See Government Code Section 4460.

    PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES

  • California Referenced Standards Code Medium relevance — show source text

    F. Customers must keep a full set of replacement fuses (PG&E must approve the size and type) onsite.

    G. Solid Blade cutouts are not fuses and therefore not acceptable as a fault−interrupting device.

    1. Replacement or Failure of Protective Equipment

    When the customer’s primary protection device malfunctions or fails to detect abnormal service conditions and trouble related to a PS customer’s equipment and the isolation of the condition and/or equipment within a reasonable time then PG&E may require the equipment to be replaced. Also, when protective equipment is repaired or replaced the equipment must meet all of the qualification and testing requirements in this document including passing inspection by PG&E personnel. If new equipment is installed it must be currently listed as PG&E approved.

    Section 9 Equipment Test Requirements

    The tests in this section apply only to the PG&E−required equipment at the POS; specifically, the breaker, the relays, and the tripping circuitry.

    The customer must complete the following requirements:

    � The equipment must pass all the tests described below.

    � The customer must submit two copies of the test reports to PG&E a minimum of 30 working days before energizing the PS facilities.

    � Each test report must identify the equipment tested and that identification must match that in the single−line or three−line diagrams.

    The customer must meet the above requirements and obtain PG&E approval of the test reports at least ten working days before PG&E energizes the PS. PG&E strongly recommends that the PS customer coordinate the test program with PG&E.

    1. Circuit Breaker Tests

    The PS customer must perform the following circuit breaker tests:

    A. Minimum−to−trip test at 70% or less of the nominal control voltage on all circuit breakers operated by PG&E−required relays.

    B. Micro−ohm test on the main circuit breaker(s) at the POS.

    C. Timing test showing the time from the trip initiation to the opening of the main poles. Proving insulation tests, as described below.

    D. Proving Insulation

    (1) Megger circuit breaker(s) at the POS operated by PG&E require relays (see Table 2 below).

    094676 Page 6 of 16 Rev. #00: 3/25/2022

    OH: Services UG: Services Primary Electric Service Requirements Greenbook

    Table 2 Circuit Breaker Positions and Connections

    Circuit Breaker Position Connection
    Circuit breaker open. Each pole to ground, pole 1 to 2, pole 3 to 4, pole 5 to 6
    Circuit breaker closed. Pole 1–ground, pole 3–ground, pole 5–ground
    If the poles are in a common tank or cell. Pole 1 to 3, pole 3 to 5, pole 5 to 1

    (2) Megger (phase−to−phase and phase−to−ground) all buses from the POS to the main breaker or fuses.

    (3) The main circuit breaker(s) must have a dielectric test performed on the insulating medium (gas or oil). This test is not required for factory−sealed, circuit−switcher interrupters.

    1. Tests for Current Transformers and Current Circuits PS customers must perform the following tests for current transformers (CTs) and current circuits associated with PG&E−required relays:

    A. Check the saturation on all CTs. If this is not possible, a manufacturer’s curve is acceptable.

  • CRSC § 104.2.2.4 Medium relevance — show source text

    [A] 104.2.2.4 Tests. Where there is insufficient evidence of compliance with the provisions of this code, the fire code official shall have the authority to require tests as evidence of compliance. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized test standards, the fire code official shall approve the testing procedures. Such tests shall be performed by a party acceptable to the fire code official.

    [A] 104.2.3 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved.

    Exception: Performance-based alternative materials, designs or methods of construction and equipment complying with the International Code Council Performance Code .

    [A] 104.2.3.1 Approval authority. An alternative material, design or method of construction shall be approved where the fire code official finds that the proposed alternative is satisfactory and complies with Sections 104.2.3.2 through 104.2.3.7, as applicable.

    [A] 104.2.3.2 Application and disposition. Where required, a request to use an alternative material, design or method of construction shall be submitted in writing to the fire code official for approval. Where the alternative material, design or method of construction is not approved, the fire code official shall respond in writing, stating the reasons the alternative was not approved.

    [A] 104.2.3.3 Compliance with code intent. An alternative material, design or method of construction shall comply with the intent of the provisions of this code.

    [A] 104.2.3.4 Equivalency criteria. An alternative material, design or method of construction shall, for the purpose intended, be not less than the equivalent of that prescribed in this code with respect to all of the following, as applicable:

    1. Quality.

    2. Strength.

    3. Effectiveness.

    4. Durability.

    5. Safety, other than fire safety.

    6. Fire safety.

    [A] 104.2.3.5 Tests. Tests conducted to demonstrate equivalency in support of an alternative material, design or method of construction application shall be of a scale that is sufficient to predict performance of the end use configuration. Tests shall be performed by a party acceptable to the fire code official.

    [A] 104.2.3.5.1 Fire tests. Tests conducted to demonstrate equivalent fire safety in support of an alternative material, design or method of construction application shall be of a scale that is sufficient to predict fire safety performance of the end use configuration. Tests shall be performed by a party acceptable to the fire code official.

    [A] 104.2.3.6 Reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall comply with Sections 104.2.3.6.1 and 104.2.3.6.2.

    [A] 104.2.3.6.1 Evaluation reports. Evaluation reports shall be issued by an approved agency and use of the evaluation report shall require approval by the fire code official for the installation. The alternate material, design or method of construction and product evaluated shall be within the scope of the fire code official’s recognition of the approved agency. Criteria used for the evaluation shall be identified within the report and, where required, provided to the fire code official.

Frequently asked questions

Which products does this part of the CRSC cover?

It focuses on detectable warning products and directional surfaces installed after January 1, 2001, and sets the test/approval scope in §§ 12‑11A.202–12‑11B.204.

Who selects the independent entity that performs evaluations?

The Division of the State Architect — Access Compliance (Department of General Services) selects the independent entity; the CRSC defines qualifications and selection expectations in §§ 12‑11A.205 and 12‑11A.211.

How often must approved products be recertified?

Detectable warning products and directional surfaces must be recertified every two years with no waiver, per § 12‑11A.206.

More in California Referenced Standards Code

Ask about the CRSC

Get cited, plain-English answers on the California Referenced Standards Code for your project — any code section, any scenario.

Start Free Trial