CEBC · California Existing Building Code
Relocated Buildings (requirements for buildings moved or relocated; Chapter 14)
Chapter 14 of the CEBC governs the safety, load compliance and required inspections for buildings that are moved or relocated.
Last reviewed: July 6, 2026
Overview
Chapter 14 of the California Existing Building Code addresses buildings that are moved or relocated and sets the minimum safety and structural requirements that apply when a building is placed at a new site. The chapter describes scope and exclusions (for example, certain manufactured homes and commercial modulars are not covered) in § 1401.1 .
Relocation typically triggers an inspection and evaluation to confirm the structure is safe for occupancy and to identify required repairs or upgrades; the moved building must also meet applicable fire- and property‑maintenance requirements and any work must comply with the CEBC and other California codes (see § 1401.2) . Chapter 14 focuses on adapting the building to the loads and hazards at its new location — including foundations (§ 1402.2), wind (§ 1402.3), seismic (§ 1402.4) and snow (§ 1402.5) requirements — and gives the code official authority to require inspections and repairs after the move (§ 1402.7) .
Relocated buildings are specifically required to comply with Chapter 14 (see Section 301.4), and the chapter ties the relocated‑building requirements to the California Building Code, California Residential Code and the California Fire Code where applicable, so designers and owners should coordinate those references when planning a move .
In this section
Code references
Grounded in the retrieved California Existing Building Code — click a citation to read the verbatim passage:
CEBC § 1.11. High relevance — show source text
The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2025 CALIFORNIA EXISTING BUILDING CODE 14-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
14-2 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
14 RELOCATED OR MOVED BUILDINGS
User notes:
About this chapter: Chapter 14 is applicable to any building that is moved or relocated. The relocation of a building will automatically cause an inspection and evaluation process that enables the jurisdiction to determine the level of compliance with the California Fire Code and the California Existing Building Code . These two codes, by their scope, are applicable to existing buildings. This is the case regardless of any repair, remodeling, alteration work or change of occupancy occurring (see the California Fire Code and California Existing Building Code.
SECTION 1401—GENERAL
1401.1 Scope. This chapter provides requirements for relocated or moved structures, including relocatable buildings as defined in Chapter 2. [HCD] The provisions of Chapter 14 are not applicable to commercial modulars, manufactured homes, mobilehomes, multi- unit manufactured housing and special purpose commercial modulars as defined in Health and Safety Code Sections 18001.8, 18007, 18008, 18008.7 and 18012.5, respectively. These structures are subject to installation/reinstallation requirements specified in the Mobile- home Parks Act (Health and Safety Code Section 18200 et seq.) and the California Code of Regulations, Title 25, Division 1, Chapter 2. Manufactured homes must meet unit identification (data plate) and certification label requirements as specified in the Code of Federal Regulations, Title 24, Subtitle B, Chapter XX, Part 3280 and Health and Safety Code Section 18032. Commercial modulars and special purpose commercial modulars must meet identification requirements in the California Code of Regulations, Title 25, Division 1, Chapter 3, Subchapter 2.
1401.1.1 Bleachers, folding and telescopic seating and grandstands. Relocated or moved bleachers, folding and telescopic seating and grandstands shall comply with ICC 300.
1401.2 Conformance. The building shall be safe for human occupancy as determined by the California Fire Code and the Interna- tional Property Maintenance Code . Any repair, alteration or change of occupancy undertaken within the moved structure shall comply with the requirements of this code applicable to the work being performed. Any field-fabricated elements shall comply with the requirements of the California Building Code or the California Residential Code, as applicable. [HCD 1 & HCD 2] After July 1, 1978, local ordinances or regulations for relocated or moved apartment houses and dwellings shall permit the retention of existing materials and methods of construction, provided the apartment house or dwelling complies with the building standards for foundations applica- ble to new construction and does not become or continue to be a substandard building. For additional information, see Health and Safety Code Section 17958.9.
SECTION 1402—REQUIREMENTS
CEBC § 1.1.11. High relevance — show source text
Chapter 10 Change of Occupancy.
The purpose of Chapter 10 is to address existing buildings that are subject to a change of occupancy. This chapter is an assembly of requirements to upgrade safety without having to comply fully as a new building. A change of occupancy classification is considered a change of occupancy, however, it will involve a higher level of regulation since the use of the building has made a more significant change.
2025 CALIFORNIA EXISTING BUILDING CODE xiii
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
Chapter 11 Additions.
Chapter 11 provides the requirements for additions, which are considered new construction. The requirements focus on safely integrating the addition with the existing building. This includes issues such as limiting the overall height and area of the building where the addition is not separated by a fire wall.
Chapter 12 Historic Buildings —Reserved
Chapter 12 is not adopted by the State of California. Historic buildings and structures shall comply with Part 8, Title 24, California Code of Regulations.
Chapter 13 Performance Compliance Methods.
Chapter 13 allows for existing buildings to be evaluated to show that alterations or a change of occupancy, while not meeting new construction requirements, will provide a level of safety to demonstrate compliance. Provisions are based on a numerical scoring system involving 21 safety parameters where, when evaluated, such buildings must meet a minimum overall safety score.
Chapter 13 is not adopted by the State of California but may be available for adoption by local ordinance, see Section 1.1.11. See Section 104.11 for consideration of alternative means of compliance.
Chapter 14 Relocated or Moved Buildings.
Chapter 14 is applicable to any building that is moved or relocated. This chapter is independent of any of the three compliance methods and focuses on the structural loads where the building is being relocated.
Chapter 15 Construction Safeguards.
Chapter 15 establishes specific regulations in order to minimize the risk to the public and adjacent property during construction. Additionally, this chapter addresses fire and life safety and means of egress during the construction process. This includes requirements for a site safety plan. This chapter is also consistent with Chapter 33 of the CBC and Chapter 33 of the California Fire Code (CFC).
Chapter 16 Referenced Standards.
Chapter 16 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 15 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.
Appendix A Guidelines for the Seismic Retrofit of Existing Buildings.
Appendix A provides guidelines for upgrading the seismic resistance capacity of different types of existing buildings. It is organized into separate chapters which deal with buildings of different types, including unreinforced masonry buildings, reinforced concrete and reinforced masonry wall buildings, and lightframe wood buildings. This appendix includes its own referenced standards.
Appendix B Supplementary Accessibility Requirements for Existing Buildings and Facilities.
Chapters 11A and 11B of the CBC contain provisions that set forth requirements for accessibility to buildings and their associated sites and facilities for people with physical disabilities. Appendix B was added to address accessibility in construction for items that are not typically enforceable through the traditional building code enforcement process.
Appendix C Guidelines for the Wind Retrofit of Existing Buildings.
CEBC § 1401.1.1 High relevance — show source text
and the California Code of Regulations, Title 25, Division 1, Chapter 2._ Manufactured homes must meet unit identification (data plate) and certification label requirements as specified in the Code of Federal Regulations, Title 24, Subtitle B, Chapter XX, Part 3280 and Health and Safety Code Section 18032. Commercial modulars and special purpose commercial modulars must meet identification requirements in the California Code of Regulations, Title 25, Division 1, Chapter 3, Subchapter 2.
1401.1.1 Bleachers, folding and telescopic seating and grandstands. Relocated or moved bleachers, folding and telescopic seating and grandstands shall comply with ICC 300.
1401.2 Conformance. The building shall be safe for human occupancy as determined by the California Fire Code and the Interna- tional Property Maintenance Code . Any repair, alteration or change of occupancy undertaken within the moved structure shall comply with the requirements of this code applicable to the work being performed. Any field-fabricated elements shall comply with the requirements of the California Building Code or the California Residential Code, as applicable. [HCD 1 & HCD 2] After July 1, 1978, local ordinances or regulations for relocated or moved apartment houses and dwellings shall permit the retention of existing materials and methods of construction, provided the apartment house or dwelling complies with the building standards for foundations applica- ble to new construction and does not become or continue to be a substandard building. For additional information, see Health and Safety Code Section 17958.9.
SECTION 1402—REQUIREMENTS
1402.1 Location on the lot. The building shall be located on the lot in accordance with the requirements of the California Building Code or the California Residential Code, as applicable.
[BS] 1402.2 Foundation. The foundation system of relocated buildings shall comply with the California Building Code or the Califor- nia Residential Code, as applicable.
[BS] 1402.2.1 Connection to the foundation. The connection of the relocated building to the foundation shall comply with the California Building Code or the California Residential Code, as applicable.
[BS] 1402.3 Wind loads. Buildings shall comply with California Building Code or California Residential Code wind provisions, as applicable.
Exceptions:
- Detached one- and two-family dwellings and Group U occupancies where wind loads at the new location are not higher than those at the previous location.
- Structural elements whose stress is not increased by more than 10 percent.
[BS] 1402.4 Seismic loads. Buildings shall comply with California Building Code or California Residential Code seismic provisions at the new location, as applicable.
Exceptions:
- Structures in Seismic Design Categories A and B and detached one- and two-family dwellings in Seismic Design Categories A, B and C where the seismic loads at the new location are not higher than those at the previous location.
- Structural elements whose stress is not increased by more than 10 percent.
[BS] 1402.5 Snow loads. Structures shall comply with California Building Code or California Residential Code snow loads, as applicable, where snow loads at the new location are higher than those at the previous location.
Exception: Structural elements whose stress is not increased by more than 5 percent.
CEBC § 102.4 High relevance — show source text
Chapter 14 is applicable to any building that is moved or relocated. This chapter is independent of any of the three compliance methods and focuses on the structural loads where the building is being relocated.
Chapter 15 Construction Safeguards.
Chapter 15 establishes specific regulations in order to minimize the risk to the public and adjacent property during construction. Additionally, this chapter addresses fire and life safety and means of egress during the construction process. This includes requirements for a site safety plan. This chapter is also consistent with Chapter 33 of the CBC and Chapter 33 of the California Fire Code (CFC).
Chapter 16 Referenced Standards.
Chapter 16 lists all of the product and installation standards and codes that are referenced throughout Chapters 1 through 15 and includes identification of the promulgators and the section numbers in which the standards and codes are referenced. As stated in Section 102.4, these standards and codes become an enforceable part of the code (to the prescribed extent of the reference) as if printed in the body of the code.
Appendix A Guidelines for the Seismic Retrofit of Existing Buildings.
Appendix A provides guidelines for upgrading the seismic resistance capacity of different types of existing buildings. It is organized into separate chapters which deal with buildings of different types, including unreinforced masonry buildings, reinforced concrete and reinforced masonry wall buildings, and lightframe wood buildings. This appendix includes its own referenced standards.
Appendix B Supplementary Accessibility Requirements for Existing Buildings and Facilities.
Chapters 11A and 11B of the CBC contain provisions that set forth requirements for accessibility to buildings and their associated sites and facilities for people with physical disabilities. Appendix B was added to address accessibility in construction for items that are not typically enforceable through the traditional building code enforcement process.
Appendix C Guidelines for the Wind Retrofit of Existing Buildings.
The purpose of Appendix C is to provide voluntary prescriptive alternatives for addressing the retrofit of buildings in high-wind areas. Currently, there are two chapters which deal with the retrofit of gable ends and the fastening of roof decks, Appendix Chapters C1 and C2, respectively. This appendix includes its own referenced standards.
Appendix D Board of Appeals.
Appendix D contains the provisions for appeal and the establishment of a board of appeals. The provisions include the application for an appeal, the makeup of the board of appeals and the conduct of the appeal process.
Appendix E Temporary Emergency Uses.
Appendix E is intended to provide guidance for designers, engineers, architects and fire and building officials on allowing temporary emergency uses of existing buildings with respect to the minimum code requirements. This appendix is a template or checklist that references the relevant code requirement of concerns.
Resource A Guidelines on Fire Ratings of Archaic Materials and Assemblies.
In the process of repair and alteration of existing buildings, based on the nature and the extent of the work, the CEBC might require certain upgrades in the fire-resistance rating of building elements, at which time it becomes critical for the designers and the code
xiv 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
officials to be able to determine the fire-resistance rating of the existing building elements as part of the overall evaluation for the assessment of the need for improvements. These guidelines are based upon the Guideline on Fire Ratings of Archaic Materials published by the National Institute of Building Sciences (NIBS).
2025 CALIFORNIA EXISTING BUILDING CODE xv
CEBC § 13-4 High relevance — show source text
1304 Investigation and Evaluation . . . . . . . . . . . . . . . . . . . 13-4
1305 Scoring and Evaluation . . . . . . . . . . . . . . . . . . . . . . . . 13-4
1306 Building Score . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
1307 Evaluation of Building Safety. . . . . . . . . . . . . . . . . . 13-16
CHAPTER 14 RELOCATED OR MOVED BUILDINGS . . . . . . 14-3
1401 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3
1402 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3
CHAPTER 15 CONSTRUCTION SAFEGUARDS . . . . . . . . . . 15-3
1501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-3
1502 Owner’s Responsibility for Fire Protection . . . . . . . 15-3
1503 Sanitary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-4
1504 Protection of Pedestrians . . . . . . . . . . . . . . . . . . . . . . 15-4
1505 Protection of Adjoining Property . . . . . . . . . . . . . . . 15-5
1506 Temporary Use of Streets, Alleys and Public Property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6
1507 Fire Extinguishers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6
1508 Means of Egress. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6
1509 Standpipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-6
1510 Automatic Sprinkler System. . . . . . . . . . . . . . . . . . . . 15-6
1511 Accessibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-7
1512 Water Supply for Fire Protection. . . . . . . . . . . . . . . . 15-7
CHAPTER 16 REFERENCED STANDARDS. . . . . . . . . . . . . . 16-3
APPENDIX A GUIDELINES FOR THE SEISMIC RETROFIT
CEBC § 11-3 High relevance — show source text
1101 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3
1102 Heights and Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3
1103 Structural. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4
1104 Energy Conservation. . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4
CHAPTER 12 HISTORIC BUILDINGS . . . . . . . . . . . . . . . . . .12-1
xviii 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS. . 13-3
1301 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3
1302 Applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3
1303 Acceptance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-4
1304 Investigation and Evaluation . . . . . . . . . . . . . . . . . . . 13-4
1305 Scoring and Evaluation . . . . . . . . . . . . . . . . . . . . . . . . 13-4
1306 Building Score . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
1307 Evaluation of Building Safety. . . . . . . . . . . . . . . . . . 13-16
CHAPTER 14 RELOCATED OR MOVED BUILDINGS . . . . . . 14-3
1401 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3
1402 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3
CHAPTER 15 CONSTRUCTION SAFEGUARDS . . . . . . . . . . 15-3
1501 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-3
1502 Owner’s Responsibility for Fire Protection . . . . . . . 15-3
1503 Sanitary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-4
CEBC § 3-3 High relevance — show source text
2025 CALIFORNIA EXISTING BUILDING CODE 3-3
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
PROVISIONS FOR ALL COMPLIANCE METHODS
members added as part of the alteration shall comply with the California Building Code . This exception shall not apply to the following:
Alterations for accessibility required by the California Building Code, Chapter 11A.
Alterations that constitute substantial improvement in flood hazard areas, which shall comply with Sections 503.2, 701.3 or 1303.1.3.
Structural provisions of Section 304, Chapter 5 or to the structural provisions of Sections 706, 805 and 906.
301.3.1 Prescriptive compliance. Alterations, additions and changes of occupancy complying with Chapter 5 of this code in buildings complying with the California Fire Code shall be considered in compliance with the provisions of this code.
Exception: Hospital buildings removed from acute care service, skilled nursing facilities, intermediate-care facilities, correctional treatment centers and acute psychiatric hospitals [OSHPD 1R, 2, 4 and 5]. The provisions of adopted sections in Chapters 3 through 5 shall control the alteration, repair and change of occupancy or function of existing structures for applications listed in Section 1.10.1, 1.10.2, 1.10.4 and 1.10.5 regulated by the Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development (OSHPD). Refer to Chapter 3A for services, systems and utilities that serve OSHPD 1 buildings.
301.3.2 Work area compliance method. A lterations, additions and changes of occupancy complying with the applicable requirements of Chapters 6 through 12 of this code shall be considered in compliance with the provisions of this code.
301.3.3 Performance compliance method. Alterations, additions and changes of occupancy complying with Chapter 13 of this code shall be considered in compliance with the provisions of this code.
Note: [HCD 1 & HCD 2] The provisions contained in Chapter 13 are not adopted by HCD, but may be available for adoption by a local ordinance. (See Section 1.1.11.)
301.4 Relocated or moved buildings. Relocated or moved buildings shall comply with the requirements of Chapter 14.
SECTION 302—GENERAL PROVISIONS
302.1 Dangerous conditions. The code official shall have the authority to require the elimination of conditions deemed dangerous.
302.1.1 Dangerous conditions. [BSC] Regardless of the extent of structural or nonstructural damage, the code official shall have the authority to require the elimination of conditions deemed dangerous.
302.2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in this code and the California Energy Code, California Fire Code, California Mechanical Code, California Plumbing Code, California Residential Code and California Electrical Code . Where provisions of the other codes conflict with provisions of this code, the provisions of this code shall take precedence.
CEBC § 301.3.2 High relevance — show source text
301.3.2 Work area compliance method. A lterations, additions and changes of occupancy complying with the applicable requirements of Chapters 6 through 12 of this code shall be considered in compliance with the provisions of this code.
301.3.3 Performance compliance method. Alterations, additions and changes of occupancy complying with Chapter 13 of this code shall be considered in compliance with the provisions of this code.
Note: [HCD 1 & HCD 2] The provisions contained in Chapter 13 are not adopted by HCD, but may be available for adoption by a local ordinance. (See Section 1.1.11.)
301.4 Relocated or moved buildings. Relocated or moved buildings shall comply with the requirements of Chapter 14.
SECTION 302—GENERAL PROVISIONS
302.1 Dangerous conditions. The code official shall have the authority to require the elimination of conditions deemed dangerous.
302.1.1 Dangerous conditions. [BSC] Regardless of the extent of structural or nonstructural damage, the code official shall have the authority to require the elimination of conditions deemed dangerous.
302.2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in this code and the California Energy Code, California Fire Code, California Mechanical Code, California Plumbing Code, California Residential Code and California Electrical Code . Where provisions of the other codes conflict with provisions of this code, the provisions of this code shall take precedence.
302.2.1 Additional codes in health care. In existing Group I-2 occupancies, ambulatory health care facilities, outpatient clinics and hyperbaric facilities, alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall also comply with NFPA 99.
302.3 Existing materials. Materials already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the code official to be unsafe.
302.4 New and replacement materials. Except as otherwise required or permitted by this code, materials permitted by the applicable code for new construction shall be used. Like materials shall be permitted for repairs and alterations, provided that unsafe conditions are not created. Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location. [HCD 1] Local ordinances or regulations shall permit the replacement, retention and extension of original materials, and the use of original methods of construction, for any building or accessory structure, provided such building or structure complied with the building code provisions in effect at the time of original construction and the building or accessory structure does not become or continue to be a substandard building. For additional information, see Health and Safety Code Sections 17912, 17920.3, 17922(d), 17922.3, 17958.8 and 17958.9.
Exception: No replacement residential garage door shall be installed to connect the replacement door to an existing residential automatic garage door opener that does not have a battery backup function designed to keep the garage door operational without interruption during an electrical outage. See Health and Safety Code Section 19892.
CEBC § 104.8 High relevance — show source text
Board of Appeals 104.8, 112, Appendix D Building Area 503.5, 503.7, 503.8, 503.9, 503.10, 503.11, 503.16, 503.18, 506.5.2, 506.5.3, 506.6, 603.1, 604.1, 1006.2, 1006.3, 1011.6, 1011.6.1, 1011.6.1.1, 1011.6.2, Table 1011.6, 1102, 1302.1.3, 1305.2.2 Dangerous 104.4, 114.1, 117.1, 202, 302.1 Height 202, 502.1, 804.4.1.1, 1011.6, Table 1011.6, 1011.7.1, 1011.7.3, 1102, 1302.1.3, 1305.2.1, Table 1306.1, A301.2 Historic Chapter 12, 202, 401.1, 501.1, 507, 601.1, 607, 701.1, 1301.1, B101 Relocatable 202, 1401.1 Relocated Chapter 14, 301.4
INDEX
Relocation of 101.2, 101.3, 101.4, 104.3, 301.1 Unsafe 104.4, 115, 116, 117.1, 202
Carbon Monoxide 308 Carpeting 105.2, 702.2 Ceiling 702.1, 801.4, 802.2.1, 802.4, 903.2.1, 1011.3, 1011.5.1, 1305.2.3.3, A105.3, A113.1 Certificate of Occupancy 110, 506.2, 1001.2,
1001.3 Change of Occupancy Chapter 10, 101.2, 101.3, 101.4, 104.3, 104.3.2, 106.2.6, 110.1, 115.5, 202, 301.1, 301.3, 307.1, 308.1, 501.1, 505.3, 506, 601.1, 605, 702.5, 1301.1, 1302.1, 1302.1.6, 1304.1.1, 1304.1.3, 1305.2.17, 1307.1.1, 1401.2, B101.2, B101.3, B101.4, C101.1, C201.1 Change of Use 202 Classroom Acoustics 502.6, 503.16, 506.6, 903.4, 1011.4, 1101.4 Code Official Chapter 1, 202, 301.3, 302.1, 302.3, 303.2.1, 304.2, 405.2.3.1, 501.2, 506.1, 506.1.1, 802.6, 804.2,
CEBC § 12-113 High relevance — show source text
1248 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-113
1249 Reserved. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-113
1250 [CA] Pharmacies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-113
1251 [CA] Veterinary Premises . . . . . . . . . . . . . . . . . . . . . . 12-113
1252 [CA] Barber Colleges and Shops. . . . . . . . . . . . . . . . 12-114
1253 [CA] Schools of Cosmetology, Cosmetological Establishments and Satellite Classrooms . . . . . 12-114
1254 [CA] Acupuncture Offices . . . . . . . . . . . . . . . . . . . . . . 12-115
CHAPTER 13 ENERGY EFFICIENCY . . . . . . . . . . . . . . . . . . 13-1
CHAPTER 14 EXTERIOR WALLS . . . . . . . . . . . . . . . . . . . . . 14-1
1401 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-3
1402 Performance Requirements . . . . . . . . . . . . . . . . . . . . 14-3
1403 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-4
1404 Installation of Wall Coverings. . . . . . . . . . . . . . . . . . . 14-5
1405 Combustible Materials on the Exterior Side of
Exterior Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16
1406 Metal Composite Material (MCM). . . . . . . . . . . . . . . 14-17
1407 Exterior Insulation and Finish Systems (EIFS). . . . 14-18
1408 High-Pressure Decorative Exterior-Grade Compact Laminates (HPL). . . . . . . . . . . . . . . . . . . 14-18
1409 Insulated Metal Panel (IMP) . . . . . . . . . . . . . . . . . . . 14-19
1410 Plastic Composite Decking . . . . . . . . . . . . . . . . . . . . 14-21 1411 Building-Integrated Photovoltaic (BIPV) Systems for Exterior Wall Coverings and Fenestration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-21
CEBC § 14-3 High relevance — show source text
2025 CALIFORNIA EXISTING BUILDING CODE 14-3
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
RELOCATED OR MOVED BUILDINGS
[BS] 1402.7 Required inspection and repairs. The code official shall be authorized to inspect, or to require approved professionals to inspect at the expense of the owner, the various structural parts of a relocated building to verify that structural components and connections have not sustained structural damage. Any repairs required by the code official as a result of such inspection shall be made prior to the final approval.
14-4 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA EXISTING BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 15 – CONSTRUCTION SAFEGUARDS
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting Agency BSC BSC-
CGSFM HCD Col6 Col7 DSA Col9 Col10 OSHPD Col12 Col13 Col14 Col15 Col16 Col17 BSCC DPH AGR DWR CEC CA SL SLC Adopting Agency BSC BSC-
CGSFM 1 2 1/AC AC SS SS/CC 1 1R 2 3 4 5 6 6 6 6 6 6 6 6 6 Adopt Entire Chapter X X Adopt Entire Chapter as
amended (amended
sections listed below)Adopt only those sections
that are listed belowX X Chapter / Section 1501 X X 1505 X X 1506 X X 1508 X X 1511 X X The state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.
2025 CALIFORNIA EXISTING BUILDING CODE 15-1
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
15-2 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
15 CONSTRUCTION SAFEGUARDS
User notes:
CEBC § 1402.2 High relevance — show source text
[BS] 1402.2 Foundation. The foundation system of relocated buildings shall comply with the California Building Code or the Califor- nia Residential Code, as applicable.
[BS] 1402.2.1 Connection to the foundation. The connection of the relocated building to the foundation shall comply with the California Building Code or the California Residential Code, as applicable.
[BS] 1402.3 Wind loads. Buildings shall comply with California Building Code or California Residential Code wind provisions, as applicable.
Exceptions:
- Detached one- and two-family dwellings and Group U occupancies where wind loads at the new location are not higher than those at the previous location.
- Structural elements whose stress is not increased by more than 10 percent.
[BS] 1402.4 Seismic loads. Buildings shall comply with California Building Code or California Residential Code seismic provisions at the new location, as applicable.
Exceptions:
- Structures in Seismic Design Categories A and B and detached one- and two-family dwellings in Seismic Design Categories A, B and C where the seismic loads at the new location are not higher than those at the previous location.
- Structural elements whose stress is not increased by more than 10 percent.
[BS] 1402.5 Snow loads. Structures shall comply with California Building Code or California Residential Code snow loads, as applicable, where snow loads at the new location are higher than those at the previous location.
Exception: Structural elements whose stress is not increased by more than 5 percent.
[BS] 1402.6 Flood hazard areas. If relocated or moved into a flood hazard area, structures shall comply with Section 1612 of the California Building Code, or Section R306 of the California Residential Code, as applicable.
2025 CALIFORNIA EXISTING BUILDING CODE 14-3
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
RELOCATED OR MOVED BUILDINGS
[BS] 1402.7 Required inspection and repairs. The code official shall be authorized to inspect, or to require approved professionals to inspect at the expense of the owner, the various structural parts of a relocated building to verify that structural components and connections have not sustained structural damage. Any repairs required by the code official as a result of such inspection shall be made prior to the final approval.
14-4 2025 CALIFORNIA EXISTING BUILDING CODE
on Jul 18, 2025 11:14 AM (CDT) THEREUNDER.
CALIFORNIA EXISTING BUILDING CODE – MATRIX ADOPTION TABLE
CHAPTER 15 – CONSTRUCTION SAFEGUARDS
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting Agency BSC BSC-
CGSFM HCD Col6 Col7 DSA Col9 Col10 OSHPD Col12 Col13 Col14 Col15 Col16 Col17 BSCC DPH AGR DWR CEC CA SL SLC Adopting
Frequently asked questions
Does Chapter 14 apply to manufactured homes or commercial modulars?
No — Chapter 14 expressly excludes commercial modulars, manufactured homes, mobilehomes and certain multi‑unit manufactured housing; those structures are regulated under other statutes and installation rules (see § 1401.1) .
What structural checks are typical when placing a building at a new site?
The code requires verification that the building meets foundation, wind, seismic and snow load requirements at the new location (examples: § 1402.2, § 1402.3, § 1402.4, § 1402.5). Exceptions exist in limited cases where new loads do not exceed original loads or stress increases are minimal .
Will the moved building be inspected after relocation?
Yes — the code official may inspect or require approved professionals to inspect structural components after relocation, and any repairs required must be completed before final approval (§ 1402.7) .
More in California Existing Building Code
- Administration and Definitions (Scope, enforcement, code official duties, definitions)
- Provisions for All Compliance Methods (general requirements that apply to all compliance options; Chapter 3 / 3A)
- Seismic retrofit and evaluation (Appendix A and seismic provisions/sections for evaluation and retrofit)
- Referenced Standards and Appendices (Chapter 16 and Appendices A–E, Resource A)
- Repairs (Chapter 4 — repair-specific rules for materials, means of egress, structural, MEP, etc.)
- Alterations — Level 1, Level 2, Level 3 (technical requirements for each alteration level; Chapters 7–9)
- Change of Occupancy and Additions (requirements for occupancy changes and additions; Chapters 10–11)
- Compliance Methods — Prescriptive, Work Area, Performance (Chapters 5, 6–11, 13)
- Relocated Buildings (requirements for buildings moved or relocated; Chapter 14)
- Construction Safeguards (site safety, means of egress and life-safety during construction; Chapter 15)
Ask about the CEBC
Get cited, plain-English answers on the California Existing Building Code for your project — any code section, any scenario.
Start Free TrialRelated in the CEBC
Administration and Definitions (Scope, enforcement, code official duties, definitions)
Provisions for All Compliance Methods (general requirements that apply to all compliance options; Chapter 3 / 3A)
Repairs (Chapter 4 — repair-specific rules for materials, means of egress, structural, MEP, etc.)
Alterations — Level 1, Level 2, Level 3 (technical requirements for each alteration level; Chapters 7–9)
Compliance Methods — Prescriptive, Work Area, Performance (Chapters 5, 6–11, 13)
Change of Occupancy and Additions (requirements for occupancy changes and additions; Chapters 10–11)
Construction Safeguards (site safety, means of egress and life-safety during construction; Chapter 15)
Referenced Standards and Appendices (Chapter 16 and Appendices A–E, Resource A)
California Existing Building Code