Atwater · Zoning · R-1-6
Atwater R-1-6 zoning: height, setbacks and lot size
In Atwater's R-1-6 zone, generally buildings can be up to 35 ft tall and the front setback is 20 ft, with the conditions listed below (Atwater code, read October 2026).
Key points
- Maximum building height: 35 ft (may be exceeded if the further conditions the code lists after this limit are met)
- Minimum front setback: 20 ft
- Minimum side setback: 5 ft
- Minimum rear setback: 15 ft
- Maximum density: 1 unit per 6,000 sq ft
R-1-6 is a zoning district in Atwater. Every value below was read from the Atwater Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in R-1-6
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 35 ft Applies: may be exceeded if the further conditions the code lists after this limit are met § 17.16.060 · code textNo building constructed in this zone shall exceed a height of 35 feet unless the following has occurred: |
|---|---|
| Minimum front setback | 20 ft § 17.16.050 · code textTable row “Minimum Front yard Setback (exterior)”, column “R-1-6”: 20 |
| Minimum side setback | 5 ft § 17.16.050 · code textTable row “Minimum Side yard Setback (interior)”, column “R-1-6”: 5 |
| Minimum rear setback | 15 ft § 17.16.050 · code textTable row “Minimum Rear yard Setback”, column “R-1-6”: 15 |
| Maximum density | 1 unit per 6,000 sq ft § 17.16.050 · code textTable row “Minimum Lot Area per dwelling unit (sq. ft.)”, column “R-1-6”: 6,000 |
Not on this page
We did not find a general stories, lot size, lot coverage, FAR limit for R-1-6 in the zoning tables we read. The code may still set one elsewhere — check the Atwater Municipal Code.
Other Atwater zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Atwater's R-1-6 zone?
35 ft (may be exceeded if the further conditions the code lists after this limit are met) — Atwater Municipal Code § 17.16.060.
What is the minimum front setback in Atwater's R-1-6 zone?
20 ft — Atwater Municipal Code § 17.16.050.
What is the minimum side setback in Atwater's R-1-6 zone?
5 ft — Atwater Municipal Code § 17.16.050.
What is the minimum rear setback in Atwater's R-1-6 zone?
15 ft — Atwater Municipal Code § 17.16.050.
What is the maximum density in Atwater's R-1-6 zone?
1 unit per 6,000 sq ft — Atwater Municipal Code § 17.16.050.
General information, not legal advice.